{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,14]],"date-time":"2026-08-14T09:27:03Z","timestamp":1786699623847,"version":"build-2736575974"},"reference-count":36,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,12,1]],"date-time":"2026-12-01T00:00:00Z","timestamp":1796083200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,12,1]],"date-time":"2026-12-01T00:00:00Z","timestamp":1796083200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,12,1]],"date-time":"2026-12-01T00:00:00Z","timestamp":1796083200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-017"},{"start":{"date-parts":[[2026,12,1]],"date-time":"2026-12-01T00:00:00Z","timestamp":1796083200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"},{"start":{"date-parts":[[2026,12,1]],"date-time":"2026-12-01T00:00:00Z","timestamp":1796083200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-012"},{"start":{"date-parts":[[2026,12,1]],"date-time":"2026-12-01T00:00:00Z","timestamp":1796083200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2026,12,1]],"date-time":"2026-12-01T00:00:00Z","timestamp":1796083200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-004"}],"funder":[{"DOI":"10.13039\/501100014795","name":"Center of Excellence for Innovation in Chemistry","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100014795","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100004704","name":"National Research Council of Thailand","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100004704","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100002842","name":"Chiang Mai University","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100002842","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Talanta"],"published-print":{"date-parts":[[2026,12]]},"DOI":"10.1016\/j.talanta.2026.130158","type":"journal-article","created":{"date-parts":[[2026,6,13]],"date-time":"2026-06-13T06:40:44Z","timestamp":1781332844000},"page":"130158","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"special_numbering":"C","title":["A cost-effective mini-CNC and negative-pressure approach for automated sample handling, low-volume sample introduction, and eluent delivery in open tubular capillary ion chromatography"],"prefix":"10.1016","volume":"310","author":[{"given":"Watcharapoln","family":"Harnmontree","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sawaeng","family":"Kawichai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jaroon","family":"Jakmunee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7178-6448","authenticated-orcid":false,"given":"Tinakorn","family":"Kanyanee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.talanta.2026.130158_bib1","doi-asserted-by":"crossref","DOI":"10.1016\/j.chemosphere.2021.131803","article-title":"Fresh and aged PM2.5 and their ion composition in rural and urban atmospheres of Northern Thailand in relation to source identification","volume":"286","author":"Chansuebsri","year":"2022","journal-title":"Chemosphere"},{"key":"10.1016\/j.talanta.2026.130158_bib2","doi-asserted-by":"crossref","DOI":"10.1016\/j.envadv.2022.100337","article-title":"Secondary sources of PM2.5 based on the vertical distribution of organic carbon, elemental carbon, and water-soluble ions in Bangkok","volume":"11","author":"Rattanapotanan","year":"2023","journal-title":"Environ. Adv."},{"key":"10.1016\/j.talanta.2026.130158_bib3","doi-asserted-by":"crossref","first-page":"1069","DOI":"10.1016\/j.apr.2017.04.009","article-title":"Effect of agricultural waste burning season on PM 2.5 -bound polycyclic aromatic hydrocarbon (PAH) levels in Northern Thailand","volume":"8","author":"Pongpiachan","year":"2017","journal-title":"Atmos. Pollut. Res."},{"key":"10.1016\/j.talanta.2026.130158_bib4","doi-asserted-by":"crossref","DOI":"10.1016\/j.atmosenv.2024.120517","article-title":"Chemical composition and origins of PM2.5 in Chiang Mai (Thailand) by integrated source apportionment and potential source areas","volume":"327","author":"Chansuebsri","year":"2024","journal-title":"Atmos. Environ."},{"key":"10.1016\/j.talanta.2026.130158_bib5","doi-asserted-by":"crossref","first-page":"210","DOI":"10.1016\/j.aca.2020.08.012","article-title":"Open tubular ion chromatography: a state-of-the-art review","volume":"1143","author":"Huang","year":"2021","journal-title":"Anal. Chim. Acta"},{"key":"10.1016\/j.talanta.2026.130158_bib6","doi-asserted-by":"crossref","first-page":"11554","DOI":"10.1021\/ac503249t","article-title":"An open tubular ion chromatograph","volume":"86","author":"Yang","year":"2014","journal-title":"Anal. Chem."},{"key":"10.1016\/j.talanta.2026.130158_bib7","doi-asserted-by":"crossref","DOI":"10.1016\/j.chroma.2023.464464","article-title":"Portable light weight open tubular ion chromatograph for field determination of environmental anions","volume":"1711","author":"Huang","year":"2023","journal-title":"J. Chrom A."},{"key":"10.1016\/j.talanta.2026.130158_bib8","doi-asserted-by":"crossref","first-page":"311","DOI":"10.1016\/j.trac.2018.03.007","article-title":"20th anniversary of axial capacitively coupled contactless conductivity detection in capillary electrophoresis","volume":"102","author":"Kub\u00e1n","year":"2018","journal-title":"TrAC-Trend Anal. Chem."},{"key":"10.1016\/j.talanta.2026.130158_bib9","doi-asserted-by":"crossref","DOI":"10.1016\/j.foodchem.2022.132055","article-title":"Open tubular capillary ion chromatography with online dilution for small ions determination in drinks","volume":"382","author":"Kanyanee","year":"2022","journal-title":"Food Chem."},{"key":"10.1016\/j.talanta.2026.130158_bib10","doi-asserted-by":"crossref","first-page":"4906","DOI":"10.1002\/elps.200800336","article-title":"Micropumps actuated negative pressure injection for microchip electrophoresis","volume":"29","author":"Li","year":"2008","journal-title":"Electrophoresis"},{"key":"10.1016\/j.talanta.2026.130158_bib11","doi-asserted-by":"crossref","first-page":"1281","DOI":"10.1002\/elps.200600553","article-title":"Parallel separation of multiple samples with negative pressure sample injection on a 3\u2010D microfluidic array chip","volume":"28","author":"Zhang","year":"2007","journal-title":"Electrophoresis"},{"key":"10.1016\/j.talanta.2026.130158_bib12","doi-asserted-by":"crossref","first-page":"258","DOI":"10.1039\/b511924c","article-title":"Negative pressure pinched sample injection for microchip-based electrophoresis","volume":"6","author":"Zhang","year":"2006","journal-title":"Lab Chip"},{"key":"10.1016\/j.talanta.2026.130158_bib13","doi-asserted-by":"crossref","first-page":"857","DOI":"10.1081\/AL-200051062","article-title":"A sample introduction method based on negative pressure in flow injection\u2010capillary electrophoresis system and its application to the alkaline\u2010earth metal cation separation","volume":"38","author":"Wang","year":"2005","journal-title":"Anal. Lett."},{"key":"10.1016\/j.talanta.2026.130158_bib14","doi-asserted-by":"crossref","first-page":"4213","DOI":"10.1002\/elps.200900378","article-title":"Pump\u2010free and low\u2010cost negative pressure sampling device for rapid sample loading in MCE","volume":"30","author":"Hu","year":"2009","journal-title":"Electrophoresis"},{"key":"10.1016\/j.talanta.2026.130158_bib15","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1016\/j.chroma.2016.12.029","article-title":"Hydrodynamic sample injection into short electrophoretic capillary in systems with a flow-gating interface","volume":"1480","author":"Opekar","year":"2017","journal-title":"J. Chromatogr. A"},{"key":"10.1016\/j.talanta.2026.130158_bib16","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1016\/j.aca.2018.07.026","article-title":"Direct sample injection from a syringe needle into a separation capillary","volume":"1042","author":"Opekar","year":"2018","journal-title":"Anal. Chim. Acta"},{"key":"10.1016\/j.talanta.2026.130158_bib17","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0158502","article-title":"Low-cost 3D printers enable high-quality and automated sample preparation and molecular detection","volume":"11","author":"Chan","year":"2016","journal-title":"PLoS One"},{"key":"10.1016\/j.talanta.2026.130158_bib18","doi-asserted-by":"crossref","DOI":"10.1016\/j.ohx.2019.e00056","article-title":"Sample treatment platform for automated integration of microextraction techniques and liquid chromatography analysis","volume":"5","author":"Medina","year":"2019","journal-title":"HardwareX"},{"key":"10.1016\/j.talanta.2026.130158_bib19","doi-asserted-by":"crossref","first-page":"2337","DOI":"10.1039\/c3lc00042g","article-title":"Microfluidics on liquid handling stations (\u03bcF-on-LHS): an industry compatible chip interface between microfluidics and automated liquid handling stations","volume":"13","author":"Waldbaur","year":"2013","journal-title":"Lab Chip"},{"key":"10.1016\/j.talanta.2026.130158_bib20","doi-asserted-by":"crossref","DOI":"10.1038\/s41598-019-56711-5","article-title":"Maskless, Rapid manufacturing of glass microfluidic devices using a picosecond pulsed laser","volume":"9","author":"Wlodarczyk","year":"2019","journal-title":"Sci. Rep."},{"key":"10.1016\/j.talanta.2026.130158_bib21","doi-asserted-by":"crossref","DOI":"10.1016\/j.snb.2022.131959","article-title":"Using multi-material fused deposition modeling (FDM) for one-step 3D printing of microfluidic capillary electrophoresis with integrated electrodes for capacitively coupled contactless conductivity detection","volume":"365","author":"Quero","year":"2022","journal-title":"Sens. Actuators B Chem."},{"key":"10.1016\/j.talanta.2026.130158_bib22","doi-asserted-by":"crossref","DOI":"10.1016\/j.microc.2023.108518","article-title":"3D printed microfluidic chemiluminescence PoC device with self-powering and integrated incubating system: validation via ALP detection on disposable \u03bcPADs","volume":"189","author":"Kumar","year":"2023","journal-title":"Microchem. J."},{"key":"10.1016\/j.talanta.2026.130158_bib23","doi-asserted-by":"crossref","first-page":"12124","DOI":"10.1039\/C9NR02754H","article-title":"Proteinase-sculptured 3D-printed graphene\/polylactic acid electrodes as potential biosensing platforms: towards enzymatic modeling of 3D-printed structures","volume":"11","author":"Manzanares-Palenzuela","year":"2019","journal-title":"Nanoscale"},{"key":"10.1016\/j.talanta.2026.130158_bib24","doi-asserted-by":"crossref","DOI":"10.1016\/j.elecom.2022.107259","article-title":"Computer numerical control-printed paper electrodes for electrochemical detection of Pseudomonas aeruginosa virulence factor pyocyanin","volume":"137","author":"Manisha","year":"2022","journal-title":"Electrochem. Commun."},{"key":"10.1016\/j.talanta.2026.130158_bib25","doi-asserted-by":"crossref","first-page":"1369","DOI":"10.1007\/s10800-022-01706-w","article-title":"Innovation in potentiometry: 3D-printed polylactic acid-based ion-selective bulk electrode membranes","volume":"52","author":"Golcs","year":"2022","journal-title":"J. Appl. Electrochem."},{"key":"10.1016\/j.talanta.2026.130158_bib26","doi-asserted-by":"crossref","first-page":"608","DOI":"10.1016\/j.snb.2016.08.031","article-title":"Dual robotic arm \u201cproduction line\u201d mass spectrometry assay guided by multiple Arduino-type microcontrollers","volume":"239","author":"Chen","year":"2017","journal-title":"Sens. Actuators B Chem."},{"key":"10.1016\/j.talanta.2026.130158_bib27","doi-asserted-by":"crossref","DOI":"10.1038\/s41598-020-70465-5","article-title":"Principles of computer-controlled linear motion applied to an open-source affordable liquid handler for automated micropipetting","volume":"10","author":"Florian","year":"2020","journal-title":"Sci. Rep."},{"key":"10.1016\/j.talanta.2026.130158_bib28","doi-asserted-by":"crossref","first-page":"1992","DOI":"10.1038\/s41596-020-0318-4","article-title":"Assembly and operation of an open-source, computer numerical controlled (CNC) robot for performing cranial microsurgical procedures","volume":"15","author":"Rynes","year":"2020","journal-title":"Nat. Protoc."},{"key":"10.1016\/j.talanta.2026.130158_bib29","doi-asserted-by":"crossref","DOI":"10.1016\/j.talanta.2024.127243","article-title":"Cost-effective low-volume sample introduction system for open tubular capillary ion chromatography via a hybrid negative pressure approach","volume":"284","author":"Harnmontree","year":"2025","journal-title":"Talanta"},{"key":"10.1016\/j.talanta.2026.130158_bib30","doi-asserted-by":"crossref","DOI":"10.1016\/j.talo.2021.100062","article-title":"Moldable capillary suppressor for open tubular ion chromatography based on a polymeric ion exchanger","volume":"4","author":"Maleki","year":"2021","journal-title":"Talanta Open"},{"key":"10.1016\/j.talanta.2026.130158_bib31","doi-asserted-by":"crossref","DOI":"10.1016\/j.talo.2020.100029","article-title":"Gradient nanopump based suppressed ion chromatography using PEEK open tubular columns","volume":"3","author":"Huang","year":"2021","journal-title":"Talanta Open"},{"key":"10.1016\/j.talanta.2026.130158_bib32","doi-asserted-by":"crossref","first-page":"5561","DOI":"10.1021\/acs.analchem.0c00505","article-title":"Nanovolume gas-free hydroxide eluent generator for open tubular ion chromatography","volume":"92","author":"Chouhan","year":"2020","journal-title":"Anal. Chem."},{"key":"10.1016\/j.talanta.2026.130158_bib33","doi-asserted-by":"crossref","first-page":"1060","DOI":"10.1021\/ie50273a022","article-title":"Glycerol viscosity tables","volume":"24","author":"Sheely","year":"1932","journal-title":"Ind. Eng. Chem."},{"key":"10.1016\/j.talanta.2026.130158_bib34","series-title":"Eurachem Guide: the Fitness for Purpose of Analytical Methods \u2013 a Laboratory Guide to Method Validation and Related Topics","author":"Cantwell","year":"2025"},{"key":"10.1016\/j.talanta.2026.130158_bib35","doi-asserted-by":"crossref","DOI":"10.1016\/j.scitotenv.2022.154929","article-title":"A clear north-to-south spatial gradience of chloride in marine aerosol in Chinese seas under the influence of East Asian Winter Monsoon","volume":"832","author":"Liu","year":"2022","journal-title":"Sci. Total Environ."},{"key":"10.1016\/j.talanta.2026.130158_bib36","doi-asserted-by":"crossref","DOI":"10.1016\/j.atmosenv.2022.119365","article-title":"A review of atmospheric aging of sea spray aerosols: potential factors affecting chloride depletion","volume":"290","author":"Su","year":"2022","journal-title":"Atmos. Environ."}],"container-title":["Talanta"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0039914026008143?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0039914026008143?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,8,14]],"date-time":"2026-08-14T08:28:32Z","timestamp":1786696112000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0039914026008143"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,12]]},"references-count":36,"alternative-id":["S0039914026008143"],"URL":"https:\/\/doi.org\/10.1016\/j.talanta.2026.130158","relation":{},"ISSN":["0039-9140"],"issn-type":[{"value":"0039-9140","type":"print"}],"subject":[],"published":{"date-parts":[[2026,12]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"A cost-effective mini-CNC and negative-pressure approach for automated sample handling, low-volume sample introduction, and eluent delivery in open tubular capillary ion chromatography","name":"articletitle","label":"Article Title"},{"value":"Talanta","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.talanta.2026.130158","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 Elsevier B.V. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}],"article-number":"130158"}}