{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,7]],"date-time":"2025-11-07T02:27:38Z","timestamp":1762482458944,"version":"build-2065373602"},"reference-count":10,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2021,4,1]],"date-time":"2021-04-01T00:00:00Z","timestamp":1617235200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2021,4,1]],"date-time":"2021-04-01T00:00:00Z","timestamp":1617235200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2021,2,23]],"date-time":"2021-02-23T00:00:00Z","timestamp":1614038400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Trauma Case Reports"],"published-print":{"date-parts":[[2021,4]]},"DOI":"10.1016\/j.tcr.2021.100448","type":"journal-article","created":{"date-parts":[[2021,3,1]],"date-time":"2021-03-01T13:01:04Z","timestamp":1614603664000},"page":"100448","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"special_numbering":"C","title":["Double plating for long-standing nonunion of the humeral shaft complicated with metaphyseal bone defect and deformity: A case report"],"prefix":"10.1016","volume":"32","author":[{"given":"Natsumi","family":"Saka","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gen","family":"Sasaki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoshinobu","family":"Watanabe","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hirotaka","family":"Kawano","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.tcr.2021.100448_bb0005","doi-asserted-by":"crossref","first-page":"1319","DOI":"10.1016\/j.injury.2008.01.014","article-title":"Humeral nailing revisited","volume":"39","author":"Rommens","year":"2008","journal-title":"Injury"},{"key":"10.1016\/j.tcr.2021.100448_bb0010","doi-asserted-by":"crossref","unstructured":"Lavini F, Renzi Brivio L, Pizzoli A, Giotakis N, Bartolozzi P. Treatment of non-union of the humerus using the Orthofix external fixator. Injury 2001;32:Sd35\u201340.","DOI":"10.1016\/S0020-1383(01)00114-0"},{"key":"10.1016\/j.tcr.2021.100448_bb0015","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1097\/00005131-200501000-00007","article-title":"Treatment of osteopenic humeral shaft nonunion with compression plating, humeral cortical allograft struts, and bone grafting","volume":"19","author":"Van Houwelingen","year":"2005","journal-title":"J. Orthop. Trauma"},{"key":"10.1016\/j.tcr.2021.100448_bb0020","doi-asserted-by":"crossref","first-page":"2685","DOI":"10.1007\/s00264-018-3911-1","article-title":"Minimally invasive plate osteosynthesis in humerus nonunion after intramedullary nailing","volume":"42","author":"Allende","year":"2018","journal-title":"Int. Orthop."},{"key":"10.1016\/j.tcr.2021.100448_bb0025","doi-asserted-by":"crossref","unstructured":"De Carolis O, Mori CM, Vicenti G, et al. A lifelong story: case report of a humeral shaft nonunion successfully treated after 30 years. Injury 2018;49:S43-.","DOI":"10.1016\/j.injury.2018.11.031"},{"key":"10.1016\/j.tcr.2021.100448_bb0030","doi-asserted-by":"crossref","unstructured":"Miska M, Findeisen S, Tanner M, et al. Treatment of nonunions in fractures of the humeral shaft according to the Diamond Concept. Bone Joint J 2016;98:81-.","DOI":"10.1302\/0301-620X.98B1.35682"},{"key":"10.1016\/j.tcr.2021.100448_bb0035","doi-asserted-by":"crossref","DOI":"10.1097\/MD.0000000000011974","article-title":"Plate fixation with autogenous bone grafting for longstanding humeral shaft nonunion: a retrospective study of 6 cases","volume":"97","author":"Feng","year":"2018","journal-title":"Medicine (Baltimore)"},{"key":"10.1016\/j.tcr.2021.100448_bb0040","doi-asserted-by":"crossref","first-page":"1315","DOI":"10.2106\/00004623-200208000-00005","article-title":"Open reduction and internal fixation of humeral nonunions: a biomechanical and clinical study","volume":"84","author":"Rubel","year":"2002","journal-title":"J. Bone Joint Surg. Am."},{"issue":"1","key":"10.1016\/j.tcr.2021.100448_bb0045","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1007\/s00264-017-3503-5","article-title":"Induced membrane technique using beta-tricalcium phosphate for reconstruction of femoral and tibial segmental bone loss due to infection: technical tips and preliminary clinical results","volume":"42","author":"Sasaki","year":"2018","journal-title":"Int. Orthop."},{"key":"10.1016\/j.tcr.2021.100448_bb0050","doi-asserted-by":"crossref","first-page":"1939","DOI":"10.2106\/JBJS.G.00690","article-title":"Linked elbow replacement: a salvage procedure for distal humeral nonunion","volume":"90","author":"Cil","year":"2008","journal-title":"J. Bone Joint Surg. Am."}],"container-title":["Trauma Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2352644021000534?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2352644021000534?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,11,7]],"date-time":"2025-11-07T02:22:45Z","timestamp":1762482165000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2352644021000534"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,4]]},"references-count":10,"alternative-id":["S2352644021000534"],"URL":"https:\/\/doi.org\/10.1016\/j.tcr.2021.100448","relation":{},"ISSN":["2352-6440"],"issn-type":[{"type":"print","value":"2352-6440"}],"subject":[],"published":{"date-parts":[[2021,4]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Double plating for long-standing nonunion of the humeral shaft complicated with metaphyseal bone defect and deformity: A case report","name":"articletitle","label":"Article Title"},{"value":"Trauma Case Reports","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.tcr.2021.100448","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2021 The Author(s). Published by Elsevier Ltd.","name":"copyright","label":"Copyright"}],"article-number":"100448"}}