{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T07:22:50Z","timestamp":1787728970524,"version":"build-2784847793"},"reference-count":10,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2023,2,1]],"date-time":"2023-02-01T00:00:00Z","timestamp":1675209600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2023,2,1]],"date-time":"2023-02-01T00:00:00Z","timestamp":1675209600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2022,12,30]],"date-time":"2022-12-30T00:00:00Z","timestamp":1672358400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Trauma &amp; Case Reports"],"published-print":{"date-parts":[[2023,2]]},"DOI":"10.1016\/j.tcr.2022.100750","type":"journal-article","created":{"date-parts":[[2022,12,31]],"date-time":"2022-12-31T02:06:39Z","timestamp":1672452399000},"page":"100750","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":1,"special_numbering":"C","title":["Drainage of an extradural haematoma by intraosseous needle in a remote hospital"],"prefix":"10.1016","volume":"43","author":[{"given":"Aruni","family":"Sen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nemer","family":"Kharroubi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anthea","family":"Pinder","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jonathan","family":"Hempenstall","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.tcr.2022.100750_bb0005","series-title":"Head Injury \u2013 Assessment & Early Management. CG","volume":"176","year":"2019"},{"key":"10.1016\/j.tcr.2022.100750_bb0010","doi-asserted-by":"crossref","first-page":"1098","DOI":"10.1016\/j.injury.2017.02.011","article-title":"Temporising extradural haematoma by craniostomy using an intraosseous needle","volume":"48","author":"Bulstrode","year":"2017","journal-title":"Injury"},{"key":"10.1016\/j.tcr.2022.100750_bb0015","doi-asserted-by":"crossref","first-page":"218","DOI":"10.1016\/j.wneu.2020.06.215","article-title":"Bedside craniostomy and serial aspiration with an intraosseous drill\/needle to temporize an acute epidural haemorrhage with mass effect","volume":"142","author":"McClung","year":"2020","journal-title":"World Neurosurg."},{"key":"10.1016\/j.tcr.2022.100750_bb0020","first-page":"76","article-title":"Temporising an extradural haematoma by intraosseous needle craniostomy in the district general hospital by non-neurosurgical doctors \u2013 a case report","volume":"19","author":"Durnford","year":"2018","journal-title":"JICS"},{"key":"10.1016\/j.tcr.2022.100750_bb0025","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1136\/emermed-2019-208943","article-title":"Cranial Burr holes in the emergency department: to drill or not to drill","volume":"37","author":"Howard","year":"2020","journal-title":"EMJ"},{"issue":"3","key":"10.1016\/j.tcr.2022.100750_bb0030","first-page":"312","article-title":"Decompression of subdural haematomas using an intraosseous needle in the emergency department: a case series","volume":"4","author":"Barro","year":"2020","journal-title":"Clin.Pract.CasesEmerg.Med."},{"key":"10.1016\/j.tcr.2022.100750_bb0035","series-title":"Advanced Trauma Life Support\u00ae \u2013 Student Course Manual","year":"2018"},{"key":"10.1016\/j.tcr.2022.100750_bb0040","series-title":"Advanced Life Support Manual","year":"2021"},{"key":"10.1016\/j.tcr.2022.100750_bb0045","series-title":"Advanced Paediatric Life Support \u2013 A Practical Approach","year":"2016"},{"key":"10.1016\/j.tcr.2022.100750_bb0050","first-page":"1158","article-title":"The Camino intracranial pressure sensor: is it optimal technology? An internal audit with a review of current intracranial pressure monitoring technologies","volume":"49","author":"Piper","year":"2001","journal-title":"Neurosurgery"}],"container-title":["Trauma &amp; Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2352644022001467?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2352644022001467?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T06:24:24Z","timestamp":1787725464000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2352644022001467"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,2]]},"references-count":10,"alternative-id":["S2352644022001467"],"URL":"https:\/\/doi.org\/10.1016\/j.tcr.2022.100750","relation":{},"ISSN":["2352-6440"],"issn-type":[{"value":"2352-6440","type":"print"}],"subject":[],"published":{"date-parts":[[2023,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Drainage of an extradural haematoma by intraosseous needle in a remote hospital","name":"articletitle","label":"Article Title"},{"value":"Trauma & Case Reports","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.tcr.2022.100750","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Crown Copyright \u00a9 2023 Published by Elsevier Ltd.","name":"copyright","label":"Copyright"}],"article-number":"100750"}}