{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,7]],"date-time":"2025-11-07T02:30:30Z","timestamp":1762482630970,"version":"build-2065373602"},"reference-count":9,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2023,10,1]],"date-time":"2023-10-01T00:00:00Z","timestamp":1696118400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2023,10,1]],"date-time":"2023-10-01T00:00:00Z","timestamp":1696118400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2023,9,2]],"date-time":"2023-09-02T00:00:00Z","timestamp":1693612800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Trauma Case Reports"],"published-print":{"date-parts":[[2023,10]]},"DOI":"10.1016\/j.tcr.2023.100928","type":"journal-article","created":{"date-parts":[[2023,9,4]],"date-time":"2023-09-04T19:25:03Z","timestamp":1693855503000},"page":"100928","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"special_numbering":"C","title":["A case report of circular external fixator with low-profile mini-fragment plate fixation: A combination of two methods for a tibial pilon fracture"],"prefix":"10.1016","volume":"47","author":[{"given":"Yohei","family":"Yanagisawa","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tomomi","family":"Kotaki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masafumi","family":"Uesugi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masashi","family":"Yamazaki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.tcr.2023.100928_bb0005","doi-asserted-by":"crossref","first-page":"723","DOI":"10.3928\/01477447-20110714-17","article-title":"Operative treatment of fractures of the tibial plafond","volume":"34","author":"Wyrsch","year":"2011","journal-title":"Orthopedics"},{"key":"10.1016\/j.tcr.2023.100928_bb0010","doi-asserted-by":"crossref","first-page":"78","DOI":"10.1097\/00005131-199902000-00002","article-title":"A staged protocol for soft tissue management in the treatment of complex pilon fractures","volume":"13","author":"Sirkin","year":"1999","journal-title":"J. Orthop. Trauma"},{"key":"10.1016\/j.tcr.2023.100928_bb0015","doi-asserted-by":"crossref","first-page":"1289","DOI":"10.1007\/s00402-010-1075-6","article-title":"Comparison of two-staged ORIF and limited internal fixation with external fixator for closed tibial plafond fractures","volume":"130","author":"Wang","year":"2010","journal-title":"Arch. Orthop. Trauma Surg."},{"key":"10.1016\/j.tcr.2023.100928_bb0020","doi-asserted-by":"crossref","first-page":"646","DOI":"10.1053\/j.jfas.2014.06.007","article-title":"A meta-analysis for postoperative complications in tibial plafond fracture: open reduction and internal fixation versus limited internal fixation combined with external fixator","volume":"54","author":"Wang","year":"2015","journal-title":"J. Foot Ankle Surg."},{"key":"10.1016\/j.tcr.2023.100928_bb0025","doi-asserted-by":"crossref","first-page":"1773","DOI":"10.1016\/j.injury.2019.07.023","article-title":"Early clinical and radiographic outcomes of a mini-fragment, low profile plating system in tibial plafond fractures","volume":"50","author":"Dang","year":"2019","journal-title":"Injury"},{"key":"10.1016\/j.tcr.2023.100928_bb0030","doi-asserted-by":"crossref","first-page":"466","DOI":"10.1007\/s00776-005-0937-1","article-title":"Development and reliability of a standard rating system for outcome measurement of foot and ankle disorders II: Interclinician and intraclinician reliability and validity of the newly established standard rating scales and Japanese Orthopaedic Association","volume":"10","author":"Niki","year":"2005","journal-title":"J. Orthop. Sci."},{"key":"10.1016\/j.tcr.2023.100928_bb0035","doi-asserted-by":"crossref","first-page":"457","DOI":"10.1007\/s00776-005-0936-2","article-title":"Development and reliability of a standard rating system for outcome measurement of foot and ankle disorders I: development of standard rating system","volume":"10","author":"Niki","year":"2005","journal-title":"J. Orthop. Sci."},{"key":"10.1016\/j.tcr.2023.100928_bb0040","first-page":"84","article-title":"Open reduction internal fixation versus external fixation with limited internal fixation for displaced comminuted closed pilon fractures: a randomised prospective study","volume":"24","author":"Rayan","year":"2018","journal-title":"J. Orthop. Trauma Rehabil."},{"key":"10.1016\/j.tcr.2023.100928_bb0045","doi-asserted-by":"crossref","first-page":"S58","DOI":"10.1016\/j.injury.2014.10.025","article-title":"Temporary bridging external fixation in distal tibial fracture","volume":"45","author":"Lavini","year":"2014","journal-title":"Injury"}],"container-title":["Trauma Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2352644023001759?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2352644023001759?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,11,7]],"date-time":"2025-11-07T02:25:03Z","timestamp":1762482303000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2352644023001759"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,10]]},"references-count":9,"alternative-id":["S2352644023001759"],"URL":"https:\/\/doi.org\/10.1016\/j.tcr.2023.100928","relation":{},"ISSN":["2352-6440"],"issn-type":[{"type":"print","value":"2352-6440"}],"subject":[],"published":{"date-parts":[[2023,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"A case report of circular external fixator with low-profile mini-fragment plate fixation: A combination of two methods for a tibial pilon fracture","name":"articletitle","label":"Article Title"},{"value":"Trauma Case Reports","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.tcr.2023.100928","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2023 The Authors. Published by Elsevier Ltd.","name":"copyright","label":"Copyright"}],"article-number":"100928"}}