{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,14]],"date-time":"2026-10-14T00:31:53Z","timestamp":1791937913582,"version":"4.3.4"},"reference-count":22,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2019,12,1]],"date-time":"2019-12-01T00:00:00Z","timestamp":1575158400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2019,12,1]],"date-time":"2019-12-01T00:00:00Z","timestamp":1575158400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2019,11,19]],"date-time":"2019-11-19T00:00:00Z","timestamp":1574121600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["tipsro.science","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Technical Innovations &amp; Patient Support in Radiation Oncology"],"published-print":{"date-parts":[[2019,12]]},"DOI":"10.1016\/j.tipsro.2019.11.007","type":"journal-article","created":{"date-parts":[[2019,12,16]],"date-time":"2019-12-16T05:44:43Z","timestamp":1576475083000},"page":"23-27","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":9,"special_numbering":"C","title":["Breath-hold versus mid-ventilation in SBRT of adrenal metastases"],"prefix":"10.1016","volume":"12","author":[{"given":"Melissa","family":"de Kuijer","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jaap","family":"van Egmond","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"E.","family":"Kouwenhoven","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dieke","family":"Bruijn-Krist","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Heleen","family":"Ceha","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mirjam","family":"Mast","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.tipsro.2019.11.007_b0005","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1200\/JCO.1995.13.1.8","article-title":"Oligometastases","volume":"13","author":"Hellman","year":"1995","journal-title":"J Clin Oncol"},{"key":"10.1016\/j.tipsro.2019.11.007_b0010","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1007\/s13304-015-0336-x","article-title":"Oligometastatic non-small cell lung cancer (NSCLC): adrenal metastases. Experience in a single institution","volume":"67","author":"Barone","year":"2015","journal-title":"Updates Surg"},{"key":"10.1016\/j.tipsro.2019.11.007_b0015","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1007\/s00066-011-2192-z","article-title":"Stereotactic body radiation therapy (SBRT) for treatment of adrenal gland metastases from non-small cell lung cancer","volume":"187","author":"Holy","year":"2011","journal-title":"Strahlentherapie Und Onkol"},{"key":"10.1016\/j.tipsro.2019.11.007_b0020","series-title":"Cancer","author":"Cingam","year":"2019"},{"key":"10.1016\/j.tipsro.2019.11.007_b0025","doi-asserted-by":"crossref","DOI":"10.21037\/cco.2017.06.30","article-title":"Stereotactic body radiotherapy for primary renal cell carcinoma and adrenal metastases","volume":"6","author":"Kothari","year":"2017","journal-title":"Chinese Clin Oncol"},{"key":"10.1016\/j.tipsro.2019.11.007_b0030","doi-asserted-by":"crossref","first-page":"919","DOI":"10.1016\/j.ijrobp.2010.11.060","article-title":"Stereotactic radiotherapy for adrenal gland metastases: University of Florence experience","volume":"82","author":"Casamassima","year":"2012","journal-title":"Int J Radiat Oncol"},{"key":"10.1016\/j.tipsro.2019.11.007_b0035","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1186\/s13014-018-1152-5","article-title":"Short-term outcomes and clinical efficacy of stereotactic body radiation therapy (SBRT) in treatment of adrenal gland metastases from lung cancer","volume":"13","author":"Zhao","year":"2018","journal-title":"Radiat Oncol"},{"issue":"4","key":"10.1016\/j.tipsro.2019.11.007_b0040","doi-asserted-by":"crossref","first-page":"621","DOI":"10.1016\/j.adro.2018.05.006","article-title":"Stereotactic body radiation for adrenal gland metastases: Outcomes and toxicity","volume":"3","author":"Toesca","year":"2018","journal-title":"Adv Radiat Oncol"},{"key":"10.1016\/j.tipsro.2019.11.007_b0045","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1016\/j.semradonc.2009.11.004","article-title":"Adaptive management of liver cancer radiotherapy","volume":"20","author":"Brock","year":"2010","journal-title":"Semin Radiat Oncol"},{"key":"10.1016\/j.tipsro.2019.11.007_b0050","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.tipsro.2018.04.001","article-title":"Two years\u2019 experience with inspiration breath-hold in liver SBRT","volume":"7","author":"Mast","year":"2018","journal-title":"Tech Innov Patient Support Radiat Oncol"},{"key":"10.1016\/j.tipsro.2019.11.007_b0055","doi-asserted-by":"crossref","first-page":"567","DOI":"10.1016\/j.ijrobp.2008.08.004","article-title":"Frameless stereotactic body radiotherapy for lung cancer using four-dimensional cone beam CT guidance","volume":"74","author":"Sonke","year":"2009","journal-title":"Int J Radiat Oncol"},{"key":"10.1016\/j.tipsro.2019.11.007_b0060","doi-asserted-by":"crossref","first-page":"1460","DOI":"10.1016\/j.ijrobp.2003.08.026","article-title":"Biologic and physical fractionation effects of random geometric errors","volume":"57","author":"van Herk","year":"2003","journal-title":"Int J Radiat Oncol"},{"key":"10.1016\/j.tipsro.2019.11.007_b0065","doi-asserted-by":"crossref","first-page":"511","DOI":"10.1016\/j.radonc.2014.01.010","article-title":"Mid-ventilation based PTV margins in stereotactic body radiotherapy (SBRT): a clinical evaluation","volume":"110","author":"Peulen","year":"2014","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.tipsro.2019.11.007_b0070","doi-asserted-by":"crossref","first-page":"1121","DOI":"10.1016\/S0360-3016(00)00518-6","article-title":"The probability of correct target dosage: dose-population histograms for deriving treatment margins in radiotherapy","volume":"47","author":"van Herk","year":"2000","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.tipsro.2019.11.007_b0075","doi-asserted-by":"crossref","first-page":"1257","DOI":"10.3109\/0284186X.2014.905699","article-title":"Differences in respiratory-induced pancreatic tumor motion between 4D treatment planning CT and daily cone beam CT, measured using intratumoral fiducials","volume":"53","author":"Lens","year":"2014","journal-title":"Acta Oncol (Madr)"},{"key":"10.1016\/j.tipsro.2019.11.007_b0080","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1016\/j.ejmp.2017.05.045","article-title":"Respiratory motion of adrenal gland metastases: Analyses using four-dimensional computed tomography images","volume":"38","author":"Chen","year":"2017","journal-title":"Phys Medica"},{"key":"10.1016\/j.tipsro.2019.11.007_b0085","doi-asserted-by":"crossref","first-page":"4295","DOI":"10.2147\/OTT.S107106","article-title":"Clinical study on the influence of motion and other factors on stereotactic radiotherapy in the treatment of adrenal gland tumor","volume":"9","author":"Wang","year":"2016","journal-title":"Onco Targets Ther"},{"key":"10.1016\/j.tipsro.2019.11.007_b0090","doi-asserted-by":"crossref","first-page":"98","DOI":"10.5301\/tj.5000222","article-title":"Evaluation of stereotactic body radiation therapy in the management of adrenal metastases from non-small cell lung cancer","volume":"101","author":"Gamsiz","year":"2015","journal-title":"Tumori J"},{"key":"10.1016\/j.tipsro.2019.11.007_b0095","doi-asserted-by":"crossref","first-page":"4789","DOI":"10.21873\/anticanres.12788","article-title":"Treatment of adrenal metastases with conventional or hypofractionated image-guided radiation therapy \u2013 patterns and outcomes","volume":"38","author":"Buergy","year":"2018","journal-title":"Anticancer Res"},{"key":"10.1016\/j.tipsro.2019.11.007_b0100","doi-asserted-by":"crossref","first-page":"253","DOI":"10.7785\/tcrt.2012.500378","article-title":"Implanting metal fiducials to guide stereotactic liver radiation: mcgill experience and review of current devices, techniques and complications","volume":"13","author":"Valentine","year":"2014","journal-title":"Technol Cancer Res Treat"},{"key":"10.1016\/j.tipsro.2019.11.007_b0105","doi-asserted-by":"crossref","first-page":"429","DOI":"10.1120\/jacmp.v17i6.6406","article-title":"Evaluation of kidney motion and target localization in abdominal SBRT patients","volume":"17","author":"Sonier","year":"2016","journal-title":"J Appl Clin Med Phys"},{"key":"10.1016\/j.tipsro.2019.11.007_b0110","doi-asserted-by":"crossref","unstructured":"Dawson LA, Eccles C, Bissonnette J, et al. Accuracy of daily image guidance for hypofractionated liver radiotherapy with active breathing control. Int J Rad Oncol Biol Phys 2005;62:1247\u201352. doi: 10.1016\/j.ijrobp.2005.03.072.","DOI":"10.1016\/j.ijrobp.2005.03.072"}],"container-title":["Technical Innovations &amp; Patient Support in Radiation Oncology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2405632419300277?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2405632419300277?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,11,7]],"date-time":"2025-11-07T08:15:46Z","timestamp":1762503346000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2405632419300277"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,12]]},"references-count":22,"alternative-id":["S2405632419300277"],"URL":"https:\/\/doi.org\/10.1016\/j.tipsro.2019.11.007","relation":{},"ISSN":["2405-6324"],"issn-type":[{"value":"2405-6324","type":"print"}],"subject":[],"published":{"date-parts":[[2019,12]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Breath-hold versus mid-ventilation in SBRT of adrenal metastases","name":"articletitle","label":"Article Title"},{"value":"Technical Innovations & Patient Support in Radiation Oncology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.tipsro.2019.11.007","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2019 The Author(s). Published by Elsevier B.V. on behalf of European Society for Radiotherapy & Oncology.","name":"copyright","label":"Copyright"}]}}