{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T21:20:01Z","timestamp":1790198401181,"version":"4.1.0"},"reference-count":22,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2024,12,1]],"date-time":"2024-12-01T00:00:00Z","timestamp":1733011200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,12,1]],"date-time":"2024-12-01T00:00:00Z","timestamp":1733011200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,11,25]],"date-time":"2024-11-25T00:00:00Z","timestamp":1732492800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["tipsro.science","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Technical Innovations &amp; Patient Support in Radiation Oncology"],"published-print":{"date-parts":[[2024,12]]},"DOI":"10.1016\/j.tipsro.2024.100295","type":"journal-article","created":{"date-parts":[[2024,11,26]],"date-time":"2024-11-26T23:35:04Z","timestamp":1732664104000},"page":"100295","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":2,"special_numbering":"C","title":["Benchmarking and performance evaluation of a novel deformable image registration software for radiotherapy CT images"],"prefix":"10.1016","volume":"32","author":[{"ORCID":"https:\/\/orcid.org\/0009-0008-8345-6041","authenticated-orcid":false,"given":"Shorug S.","family":"Alshammari","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9796-8576","authenticated-orcid":false,"given":"Sridhar","family":"Yaddanapudi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bla\u017e","family":"Ku\u0161nik","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rok","family":"Ivan\u010di\u010d","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0009-6440-5940","authenticated-orcid":false,"given":"Kristjan","family":"Anderle","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0001-1249-6520","authenticated-orcid":false,"given":"Jonathan G.","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6794-2540","authenticated-orcid":false,"given":"Keith M.","family":"Furutani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chris J.","family":"Beltran","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bo","family":"Lu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"4","key":"10.1016\/j.tipsro.2024.100295_b0005","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1078\/0939-3889-00327","article-title":"Deformable registration for image-guided radiation therapy","volume":"16","author":"Sarrut","year":"2006","journal-title":"Z Med Phys"},{"issue":"9","key":"10.1016\/j.tipsro.2024.100295_b0010","doi-asserted-by":"crossref","first-page":"1225","DOI":"10.1080\/0284186X.2019.1620331","article-title":"Deformable image registration for radiation therapy: principle, methods, applications and evaluation","volume":"58","author":"Rigaud","year":"2019","journal-title":"Acta Oncol"},{"issue":"4","key":"10.1016\/j.tipsro.2024.100295_b0015","doi-asserted-by":"crossref","first-page":"282","DOI":"10.1016\/j.prro.2021.02.007","article-title":"Rigid and deformable image registration for radiation therapy: a self-study evaluation guide for NRG oncology clinical trial participation","volume":"11","author":"Rong","year":"2021","journal-title":"Pract Radiat Oncol"},{"issue":"4","key":"10.1016\/j.tipsro.2024.100295_b0020","doi-asserted-by":"crossref","first-page":"428","DOI":"10.1177\/1533034614553891","article-title":"Quantitative analysis tools and digital phantoms for deformable image registration quality assurance","volume":"14","author":"Kim","year":"2015","journal-title":"Technol Cancer Res Treat"},{"issue":"1","key":"10.1016\/j.tipsro.2024.100295_b0025","doi-asserted-by":"crossref","first-page":"3834","DOI":"10.1120\/jacmp.v14i1.3834","article-title":"Validation of three deformable image registration algorithms for the thorax","volume":"14","author":"Latifi","year":"2013","journal-title":"J Appl Clin Med Phys"},{"issue":"3","key":"10.1016\/j.tipsro.2024.100295_b0030","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1120\/jacmp.v17i3.5735","article-title":"Benchmarking of five commercial deformable image registration algorithms for head and neck patients","volume":"17","author":"Pukala","year":"2016","journal-title":"J Appl Clin Med Phys"},{"issue":"2","key":"10.1016\/j.tipsro.2024.100295_b0035","doi-asserted-by":"crossref","first-page":"748","DOI":"10.1002\/mp.12737","article-title":"Performance of commercially available deformable image registration platforms for contour propagation using patient-based computational phantoms: a multi-institutional study","volume":"45","author":"Loi","year":"2018","journal-title":"Med Phys"},{"issue":"5","key":"10.1016\/j.tipsro.2024.100295_b0040","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1002\/acm2.13242","article-title":"Variability in commercially available deformable image registration: a multi-institution analysis using virtual head and neck phantoms","volume":"22","author":"Kubli","year":"2021","journal-title":"J Appl Clin Med Phys"},{"key":"10.1016\/j.tipsro.2024.100295_b0045","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1016\/j.media.2016.06.030","article-title":"A survey of medical image registration - under review","volume":"33","author":"Viergever","year":"2016","journal-title":"Med Image Anal"},{"key":"10.1016\/j.tipsro.2024.100295_b0050","doi-asserted-by":"crossref","unstructured":"Brock KK et al. Use of image registration and fusion algorithms and techniques in radiotherapy: Report of the AAPM Radiation Therapy Committee Task Group No. 132. Med Phys, 2017;44(7):e43\u2013e76.","DOI":"10.1002\/mp.12256"},{"issue":"7","key":"10.1016\/j.tipsro.2024.100295_b0055","doi-asserted-by":"crossref","first-page":"1849","DOI":"10.1088\/0031-9155\/54\/7\/001","article-title":"A framework for evaluation of deformable image registration spatial accuracy using large landmark point sets","volume":"54","author":"Castillo","year":"2009","journal-title":"Phys Med Biol"},{"issue":"1","key":"10.1016\/j.tipsro.2024.100295_b0060","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1088\/0031-9155\/55\/1\/018","article-title":"Four-dimensional deformable image registration using trajectory modeling","volume":"55","author":"Castillo","year":"2010","journal-title":"Phys Med Biol"},{"issue":"11","key":"10.1016\/j.tipsro.2024.100295_b0065","doi-asserted-by":"crossref","DOI":"10.1118\/1.4823467","article-title":"A virtual phantom library for the quantification of deformable image registration uncertainties in patients with cancers of the head and neck","volume":"40","author":"Pukala","year":"2013","journal-title":"Med Phys"},{"key":"10.1016\/j.tipsro.2024.100295_b0070","unstructured":"Ma B et al. Image registration with minimum spanning tree algorithm. In: Proceedings 2000 International Conference on Image Processing (Cat. No.00CH37101). 2000."},{"key":"10.1016\/j.tipsro.2024.100295_b0075","series-title":"2017 IEEE International Conference on Image Processing (ICIP)","article-title":"A two-stage minimum spanning tree (MST) based clustering algorithm for 2D deformable registration of time sequenced images","author":"Saha","year":"2017"},{"key":"10.1016\/j.tipsro.2024.100295_b0080","doi-asserted-by":"crossref","first-page":"29","DOI":"10.17148\/IJARCCE.2016.5107","article-title":"A comparative analysis of image interpolation algorithms","volume":"5","author":"Parsania","year":"2016","journal-title":"IJARCCE"},{"issue":"1","key":"10.1016\/j.tipsro.2024.100295_b0085","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1088\/0031-9155\/42\/1\/008","article-title":"Adaptive radiation therapy","volume":"42","author":"Yan","year":"1997","journal-title":"Phys Med Biol"},{"issue":"2","key":"10.1016\/j.tipsro.2024.100295_b0090","doi-asserted-by":"crossref","first-page":"422","DOI":"10.1016\/j.ijrobp.2016.05.012","article-title":"Multi-institutional validation study of commercially available deformable image registration software for thoracic images","volume":"96","author":"Kadoya","year":"2016","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.tipsro.2024.100295_b0095","unstructured":"Piper J, Richmond J, Nelson A. VoxAlign deformation engine. White Paper, MIM Software Inc; 2018."},{"key":"10.1016\/j.tipsro.2024.100295_b0100","doi-asserted-by":"crossref","unstructured":"Mattes D et al. Nonrigid multimodality image registration. Medical Imaging 2001. Vol. 4322. 2001: SPIE.","DOI":"10.1117\/12.431134"},{"key":"10.1016\/j.tipsro.2024.100295_b0105","author":"Ibanez","year":"2003","journal-title":"The ITK Software Guide"},{"issue":"1","key":"10.1016\/j.tipsro.2024.100295_b0110","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1093\/jrr\/rrt093","article-title":"Evaluation of various deformable image registration algorithms for thoracic images","volume":"55","author":"Kadoya","year":"2014","journal-title":"J Radiat Res"}],"container-title":["Technical Innovations &amp; Patient Support in Radiation Oncology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2405632424000623?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2405632424000623?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2024,12,14]],"date-time":"2024-12-14T21:23:04Z","timestamp":1734211384000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2405632424000623"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12]]},"references-count":22,"alternative-id":["S2405632424000623"],"URL":"https:\/\/doi.org\/10.1016\/j.tipsro.2024.100295","relation":{},"ISSN":["2405-6324"],"issn-type":[{"value":"2405-6324","type":"print"}],"subject":[],"published":{"date-parts":[[2024,12]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Benchmarking and performance evaluation of a novel deformable image registration software for radiotherapy CT images","name":"articletitle","label":"Article Title"},{"value":"Technical Innovations & Patient Support in Radiation Oncology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.tipsro.2024.100295","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 The Author(s). Published by Elsevier B.V. on behalf of European Society for Radiotherapy & Oncology.","name":"copyright","label":"Copyright"}],"article-number":"100295"}}