{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,8,22]],"date-time":"2023-08-22T03:08:34Z","timestamp":1692673714444},"reference-count":12,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2017,1,1]],"date-time":"2017-01-01T00:00:00Z","timestamp":1483228800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","transplantation-proceedings.org","clinicalkey.es","clinicalkey.com.au","clinicalkey.fr","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Transplantation Proceedings"],"published-print":{"date-parts":[[2017,1]]},"DOI":"10.1016\/j.transproceed.2016.10.012","type":"journal-article","created":{"date-parts":[[2017,1,16]],"date-time":"2017-01-16T12:52:11Z","timestamp":1484571131000},"page":"121-124","update-policy":"http:\/\/dx.doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":6,"title":["Cerebrovascular Accident Rate Is Different Between Centrifugal and Axial-Flow Pumps, but Survival and Driveline Infection Rates Are Similar"],"prefix":"10.1016","volume":"49","author":[{"given":"M.","family":"Kimura","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"K.","family":"Nawata","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"O.","family":"Kinoshita","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"H.","family":"Yamauchi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Y.","family":"Itoda","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"T.","family":"Imamura","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M.","family":"Hatano","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"K.","family":"Kinugawa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M.","family":"Ono","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.transproceed.2016.10.012_bib1","doi-asserted-by":"crossref","first-page":"1495","DOI":"10.1016\/j.healun.2015.10.003","article-title":"Seventh INTERMACS annual report: 15,000 patients and counting","volume":"34","author":"Kirklin","year":"2015","journal-title":"J\u00a0Heart Lung Transplant"},{"key":"10.1016\/j.transproceed.2016.10.012_bib2","doi-asserted-by":"crossref","first-page":"2017","DOI":"10.1016\/j.transproceed.2013.01.005","article-title":"Improved survival in patients with continuous-flow ventricular assist device for bridge to heart transplantation","volume":"45","author":"Ono","year":"2013","journal-title":"Transplant Proc"},{"key":"10.1016\/j.transproceed.2016.10.012_bib3","doi-asserted-by":"crossref","first-page":"604","DOI":"10.1111\/jocs.12158","article-title":"Clinical differences between continuous flow ventricular assist devices: a comparison between Heartmate II and Heartware HVAD","volume":"28","author":"Lalonde","year":"2013","journal-title":"J\u00a0Card Surg"},{"key":"10.1016\/j.transproceed.2016.10.012_bib4","doi-asserted-by":"crossref","first-page":"506","DOI":"10.1016\/j.athoracsur.2013.08.048","article-title":"Heartware and Heartmate II left ventricular assist devices as bridge to transplantation: a comparative analysis","volume":"97","author":"Topkara","year":"2014","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.transproceed.2016.10.012_bib5","doi-asserted-by":"crossref","first-page":"599","DOI":"10.1016\/j.healun.2014.02.015","article-title":"Post-approval study of a highly pulsed, low-shear-rate, continuous-flow, left ventricular assist device, evaheart: a Japanese multicenter study using J-MACS","volume":"33","author":"Saito","year":"2014","journal-title":"J\u00a0Heart Lung Transplant"},{"key":"10.1016\/j.transproceed.2016.10.012_bib6","doi-asserted-by":"crossref","first-page":"1736","DOI":"10.1253\/circj.CJ-12-1410","article-title":"Duraheart magnetically levitated left ventricular assist device: Osaka University experience","volume":"77","author":"Sakaguchi","year":"2013","journal-title":"Circ J"},{"key":"10.1016\/j.transproceed.2016.10.012_bib7","doi-asserted-by":"crossref","first-page":"1578","DOI":"10.1016\/j.healun.2015.08.017","article-title":"Adverse neurologic events in patients bridged with long-term mechanical circulatory support: a device-specific comparative analysis","volume":"34","author":"Coffin","year":"2015","journal-title":"J\u00a0Heart Lung Transplant"},{"key":"10.1016\/j.transproceed.2016.10.012_bib8","first-page":"383","article-title":"Midterm outcome of implantable left ventricular assist devices as a bridge to transplantation: single-center experience in Japan","volume":"65","author":"Kimura","year":"2015","journal-title":"J\u00a0Cardiol"},{"key":"10.1016\/j.transproceed.2016.10.012_bib9","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1007\/s11748-015-0538-7","article-title":"Early and mid-term outcomes of left ventricular assist device implantation and future prospects","volume":"63","author":"Hata","year":"2015","journal-title":"Gen Thorac Cardiovasc Surg"},{"key":"10.1016\/j.transproceed.2016.10.012_bib10","doi-asserted-by":"crossref","first-page":"1036","DOI":"10.1093\/ejcts\/ezs483","article-title":"Lower body surface area is highly related to mortality due to stroke or systemic bleeding in patients receiving an axial flow blood pump as a left ventricular assist device","volume":"43","author":"Komoda","year":"2013","journal-title":"Eur J Cardiothorac Surg"},{"key":"10.1016\/j.transproceed.2016.10.012_bib11","doi-asserted-by":"crossref","first-page":"493","DOI":"10.1016\/j.athoracsur.2012.09.020","article-title":"The development of aortic insufficiency in continuous-flow left ventricular assist device-supported patients","volume":"95","author":"Aggarwal","year":"2013","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.transproceed.2016.10.012_bib12","doi-asserted-by":"crossref","first-page":"104","DOI":"10.1253\/circj.CJ-14-0944","article-title":"Aortic insufficiency in patients with sustained left ventricular systolic dysfunction after axial flow assist device implantation","volume":"79","author":"Imamura","year":"2015","journal-title":"Circ J"}],"container-title":["Transplantation Proceedings"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0041134516307679?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0041134516307679?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2018,9,5]],"date-time":"2018-09-05T02:56:58Z","timestamp":1536116218000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0041134516307679"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,1]]},"references-count":12,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2017,1]]}},"alternative-id":["S0041134516307679"],"URL":"https:\/\/doi.org\/10.1016\/j.transproceed.2016.10.012","relation":{},"ISSN":["0041-1345"],"issn-type":[{"value":"0041-1345","type":"print"}],"subject":[],"published":{"date-parts":[[2017,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Cerebrovascular Accident Rate Is Different Between Centrifugal and Axial-Flow Pumps, but Survival and Driveline Infection Rates Are Similar","name":"articletitle","label":"Article Title"},{"value":"Transplantation Proceedings","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.transproceed.2016.10.012","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2017 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}