{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T02:48:22Z","timestamp":1790736502256,"version":"4.1.0"},"reference-count":56,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2018,11,1]],"date-time":"2018-11-01T00:00:00Z","timestamp":1541030400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"funder":[{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"publisher","award":["1R03AR066826-01A1"],"award-info":[{"award-number":["1R03AR066826-01A1"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000069","name":"National Institute of Arthritis and Musculoskeletal and Skin Diseases","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100000069","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Tribology International"],"published-print":{"date-parts":[[2018,11]]},"DOI":"10.1016\/j.triboint.2018.07.005","type":"journal-article","created":{"date-parts":[[2018,7,4]],"date-time":"2018-07-04T17:44:31Z","timestamp":1530726271000},"page":"568-574","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":29,"special_numbering":"C","title":["Friction between a polyethylene pin and a microtextured CoCrMo disc, and its correlation to polyethylene wear, as a function of sliding velocity and contact pressure, in the context of metal-on-polyethylene prosthetic hip implants"],"prefix":"10.1016","volume":"127","author":[{"given":"A.","family":"Borjali","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"K.","family":"Monson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"B.","family":"Raeymaekers","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.triboint.2018.07.005_bib1","unstructured":"Foran J. Total Hip Replacement - OrthoInfo - AAOS n.d. https:\/\/orthoinfo.aaos.org\/en\/treatment\/total-hip-replacement (accessed March 25, 2018)."},{"key":"10.1016\/j.triboint.2018.07.005_bib2","doi-asserted-by":"crossref","first-page":"3070","DOI":"10.1007\/s11999-010-1399-0","article-title":"Risk of subsequent revision after primary and revision total joint arthroplasty","volume":"468","author":"Ong","year":"2010","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.triboint.2018.07.005_bib3","doi-asserted-by":"crossref","first-page":"5","DOI":"10.3389\/fendo.2017.00005","article-title":"Chemokines associated with pathologic responses to orthopedic implant debris","volume":"8","author":"Hallab","year":"2017","journal-title":"Front Endocrinol (Lausanne)"},{"key":"10.1016\/j.triboint.2018.07.005_bib4","doi-asserted-by":"crossref","first-page":"1954","DOI":"10.1016\/j.arth.2017.01.037","article-title":"Complications after revision total hip arthroplasty in the medicare population","volume":"32","author":"Badarudeen","year":"2017","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.triboint.2018.07.005_bib5","doi-asserted-by":"crossref","first-page":"240","DOI":"10.1097\/BLO.0b013e31804b4147","article-title":"The biology of aseptic osteolysis","volume":"460","author":"Holt","year":"2007","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.triboint.2018.07.005_bib6","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1016\/j.ijsu.2016.12.122","article-title":"Risk factors for dislocation after revision total hip arthroplasty: a systematic review and meta-analysis","volume":"38","author":"Guo","year":"2017","journal-title":"Int J Surg"},{"key":"10.1016\/j.triboint.2018.07.005_bib7","doi-asserted-by":"crossref","first-page":"1329","DOI":"10.1016\/j.arth.2013.01.012","article-title":"Revision surgery after total joint arthroplasty: a complication-based analysis using worldwide arthroplasty registers","volume":"28","author":"Sadoghi","year":"2013","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.triboint.2018.07.005_bib8","doi-asserted-by":"crossref","first-page":"3802","DOI":"10.1016\/j.arth.2017.07.027","article-title":"Patient-specific contact stress does not predict polyethylene wear rate in a specific pressfit cup","volume":"32","author":"Matziolis","year":"2017","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.triboint.2018.07.005_bib9","doi-asserted-by":"crossref","first-page":"717","DOI":"10.1016\/j.otsr.2016.04.010","article-title":"Comparison of wear rate and osteolysis between annealed and remelted highly cross-linked polyethylene in total hip arthroplasty. A case control study at 7 to 10 years follow-up","volume":"102","author":"Takada","year":"2016","journal-title":"Orthop Traumatol Surg Res"},{"key":"10.1016\/j.triboint.2018.07.005_bib10","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1097\/01.blo.0000203484.90711.52","article-title":"Early failure in total hip arthroplasty","volume":"447","author":"Dobzyniak","year":"2006","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.triboint.2018.07.005_bib11","doi-asserted-by":"crossref","first-page":"144","DOI":"10.2106\/00004623-200710001-00015","article-title":"Future clinical and economic impact of revision total hip and knee arthroplasty","volume":"89","author":"Kurtz","year":"2007","journal-title":"J Bone Jt Surg"},{"key":"10.1016\/j.triboint.2018.07.005_bib12","series-title":"The clinical performance of highly cross-linked UHMWPE in hip replacements. UHMWPE biomater. Handb","first-page":"57","author":"Kurtz","year":"2015"},{"key":"10.1016\/j.triboint.2018.07.005_bib13","doi-asserted-by":"crossref","first-page":"2262","DOI":"10.1007\/s11999-011-1872-4","article-title":"History and systematic review of wear and osteolysis outcomes for first-generation highly crosslinked polyethylene","volume":"469","author":"Kurtz","year":"2011","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.triboint.2018.07.005_bib14","doi-asserted-by":"crossref","first-page":"1514","DOI":"10.1002\/jor.23168","article-title":"Fatigue toughness of irradiated vitamin E\/UHMWPE blends","volume":"34","author":"Doshi","year":"2016","journal-title":"J Orthop Res"},{"key":"10.1016\/j.triboint.2018.07.005_bib15","doi-asserted-by":"crossref","first-page":"316","DOI":"10.1002\/jbm.b.33368","article-title":"Effects of simulated oxidation on the in vitro wear and mechanical properties of irradiated and melted highly crosslinked UHMWPE","volume":"104","author":"Oral","year":"2016","journal-title":"J Biomed Mater Res B Appl Biomater"},{"key":"10.1016\/j.triboint.2018.07.005_bib16","doi-asserted-by":"crossref","first-page":"1251","DOI":"10.1016\/j.arth.2015.12.023","article-title":"Five-year experience of vitamin e\u2013diffused highly cross-linked polyethylene wear in total hip arthroplasty assessed by radiostereometric analysis","volume":"31","author":"Nebergall","year":"2016","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.triboint.2018.07.005_bib17","doi-asserted-by":"crossref","first-page":"349","DOI":"10.1016\/j.triboint.2015.12.041","article-title":"Experimental comparison on tribological pairs UHMWPE\/TIAL6V4 alloy, UHMWPE\/AISI316L austenitic stainless and UHMWPE\/AL2O3 ceramic, under dry and lubricated conditions","volume":"96","author":"Ruggiero","year":"2016","journal-title":"Tribol Int"},{"key":"10.1016\/j.triboint.2018.07.005_bib18","doi-asserted-by":"crossref","first-page":"45","DOI":"10.5435\/JAAOS-D-15-00754","article-title":"Bearing surfaces for total hip arthroplasty","volume":"26","author":"Lachiewicz","year":"2018","journal-title":"J Am Acad Orthop Surg"},{"key":"10.1016\/j.triboint.2018.07.005_bib19","doi-asserted-by":"crossref","first-page":"619","DOI":"10.1016\/S0142-9612(02)00376-9","article-title":"Deposition of highly adhesive ZrO2 coating on Ti and CoCrMo implant materials using plasma spraying","volume":"24","author":"Yang","year":"2003","journal-title":"Biomaterials"},{"key":"10.1016\/j.triboint.2018.07.005_bib20","doi-asserted-by":"crossref","first-page":"532","DOI":"10.5301\/hipint.5000513","article-title":"Wear of XLPE liner against zirconium heads in cementless total hip arthroplasty for patients under 40 Years of age","volume":"27","author":"Sonohata","year":"2017","journal-title":"HIP Int"},{"key":"10.1016\/j.triboint.2018.07.005_bib21","doi-asserted-by":"crossref","first-page":"94","DOI":"10.4161\/biom.20710","article-title":"Evaluation of silicon nitride as a wear resistant and resorbable alternative for total hip joint replacement","volume":"2","author":"Olofsson","year":"2012","journal-title":"Biomatter"},{"key":"10.1016\/j.triboint.2018.07.005_bib22","article-title":"Preliminary evaluations on development of new materials for hip joint femoral head","author":"Aherwar","year":"2017","journal-title":"Proc Inst Mech Eng Part L J Mater Des Appl"},{"key":"10.1016\/j.triboint.2018.07.005_bib23","doi-asserted-by":"crossref","first-page":"276","DOI":"10.1016\/j.compositesb.2015.07.019","article-title":"Advanced biomaterials in hip joint arthroplasty. A review on polymer and ceramics composites as alternative bearings","volume":"83","author":"Affatato","year":"2015","journal-title":"Compos B Eng"},{"key":"10.1016\/j.triboint.2018.07.005_bib24","doi-asserted-by":"crossref","first-page":"492","DOI":"10.1016\/j.precisioneng.2009.01.005","article-title":"Study on long life of artificial joints by investigating optimal sliding surface geometry for improvement in wear resistance","volume":"33","author":"Sawano","year":"2009","journal-title":"Precis Eng"},{"key":"10.1016\/j.triboint.2018.07.005_bib25","doi-asserted-by":"crossref","first-page":"332","DOI":"10.1016\/S0883-5403(00)90670-3","article-title":"Reduction of polyethylene wear by concave dimples on the frictional surface in artificial hip joints","volume":"15","author":"Ito","year":"2000","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.triboint.2018.07.005_bib26","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1016\/j.jmbbm.2015.10.023","article-title":"Towards near-permanent CoCrMo prosthesis surface by combining micro-texturing and low temperature plasma carburising","volume":"55","author":"Dong","year":"2016","journal-title":"J Mech Behav Biomed Mater"},{"key":"10.1016\/j.triboint.2018.07.005_bib27","doi-asserted-by":"crossref","first-page":"409","DOI":"10.1007\/s11249-014-0418-9","article-title":"Optimization of surface texturing for contact between steel and ultrahigh molecular weight polyethylene under boundary lubrication","volume":"56","author":"Cho","year":"2014","journal-title":"Tribol Lett"},{"key":"10.1016\/j.triboint.2018.07.005_bib28","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1016\/j.wear.2014.04.001","article-title":"A patterned microtexture to reduce friction and increase longevity of prosthetic hip joints","volume":"315","author":"Chyr","year":"2014","journal-title":"Wear"},{"key":"10.1016\/j.triboint.2018.07.005_bib29","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1016\/j.wear.2017.09.014","article-title":"Using a patterned microtexture to reduce polyethylene wear in metal-on-polyethylene prosthetic bearing couples","volume":"392\u2013393","author":"Borjali","year":"2017","journal-title":"Wear"},{"key":"10.1016\/j.triboint.2018.07.005_bib30","doi-asserted-by":"crossref","first-page":"178","DOI":"10.1016\/j.triboint.2018.04.007","article-title":"Microtextured CoCrMo alloy for use in metal-on-polyethylene prosthetic joint bearings: multi-directional wear and corrosion measurements","volume":"124","author":"Langhorn","year":"2018","journal-title":"Tribol Int"},{"key":"10.1016\/j.triboint.2018.07.005_bib31","first-page":"210","article-title":"Basic gait parameters: reference data for normal subjects, 10-79 years of age","volume":"30","author":"Oberg","year":"1993","journal-title":"J Rehabil Res Dev"},{"key":"10.1016\/j.triboint.2018.07.005_bib32","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1016\/j.jbiomech.2017.04.014","article-title":"Speed, age, sex, and body mass index provide a rigorous basis for comparing the kinematic and kinetic profiles of the lower extremity during walking","volume":"58","author":"Chehab","year":"2017","journal-title":"J Biomech"},{"key":"10.1016\/j.triboint.2018.07.005_bib33","doi-asserted-by":"crossref","first-page":"306","DOI":"10.2519\/jospt.1995.21.6.306","article-title":"Dynamic foot biomechanics","volume":"21","author":"Rodgers","year":"1995","journal-title":"J Orthop Sports Phys Ther"},{"key":"10.1016\/j.triboint.2018.07.005_bib34","doi-asserted-by":"crossref","DOI":"10.1142\/S0219519416500299","article-title":"Effect of age, ggender, and walkway length on accelerometry-based gait parameters for healthy adult subjects","volume":"16","author":"Yoneyama","year":"2016","journal-title":"J Mech Med Biol"},{"key":"10.1016\/j.triboint.2018.07.005_bib35","doi-asserted-by":"crossref","first-page":"308","DOI":"10.1002\/art.1790100505","article-title":"Acetabular pressures during hip arthritis exercises","volume":"10","author":"Tackson","year":"1997","journal-title":"Arthritis Care Res (Hoboken)"},{"key":"10.1016\/j.triboint.2018.07.005_bib36","doi-asserted-by":"crossref","first-page":"106","DOI":"10.1016\/j.triboint.2014.04.025","article-title":"Designing prosthetic knee joints with bio-inspired bearing surfaces","volume":"77","author":"Qiu","year":"2014","journal-title":"Tribol Int"},{"key":"10.1016\/j.triboint.2018.07.005_bib37","series-title":"Standard specification for ultra-high-molecular-weight polyethylene powder and fabricated form for surgical implants","author":"ASTM F648-14","year":"2014"},{"key":"10.1016\/j.triboint.2018.07.005_bib38","first-page":"135","article-title":"The effect of determining topography parameters on analyzing elastic contact between isotropic rough surfaces","author":"Pawar","year":"2012","journal-title":"J Tribol"},{"key":"10.1016\/j.triboint.2018.07.005_bib39","series-title":"Standard specification for wrought Cobalt-28Chromium-6Molybdenum alloys for surgical implants (UNS R31537, UNS R31538, and UNS R31539","author":"ASTM F1537-08","year":"2008"},{"key":"10.1016\/j.triboint.2018.07.005_bib40","series-title":"Standard test method for wear testing of polymeric materials used in total joint prostheses","author":"ASTM F732-17","year":"2017"},{"key":"10.1016\/j.triboint.2018.07.005_bib41","doi-asserted-by":"crossref","first-page":"518","DOI":"10.1016\/j.medengphy.2016.03.004","article-title":"The contact mechanics and occurrence of edge loading in modular metal-on-polyethylene total hip replacement during daily activities","volume":"38","author":"Hua","year":"2016","journal-title":"Med Eng Phys"},{"key":"10.1016\/j.triboint.2018.07.005_bib42","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0155612","article-title":"Standardized loads acting in hip implants","volume":"11","author":"Bergmann","year":"2016","journal-title":"PLoS One"},{"key":"10.1016\/j.triboint.2018.07.005_bib43","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1016\/j.jbiomech.2016.11.060","article-title":"Comparison of in vivo measured loads in knee, hip and spinal implants during level walking","volume":"51","author":"Damm","year":"2017","journal-title":"J Biomech"},{"key":"10.1016\/j.triboint.2018.07.005_bib44","doi-asserted-by":"crossref","first-page":"359","DOI":"10.4103\/ortho.IJOrtho_280_17","article-title":"The history of biomechanics in total hip arthroplasty","volume":"51","author":"Houcke","year":"2017","journal-title":"Indian J Orthop"},{"key":"10.1016\/j.triboint.2018.07.005_bib45","doi-asserted-by":"crossref","first-page":"308","DOI":"10.1002\/art.1790100505","article-title":"Acetabular pressures during hip arthritis exercises","volume":"10","author":"Tackson","year":"1997","journal-title":"Arthritis Care Res"},{"key":"10.1016\/j.triboint.2018.07.005_bib46","doi-asserted-by":"crossref","first-page":"723","DOI":"10.1243\/09544119JEIM146","article-title":"Effect of contact pressure on wear and friction of ultra-high molecular weight polyethylene in multidirectional sliding","volume":"220","author":"Saikko","year":"2006","journal-title":"Proc Inst Mech Eng Part H J Eng Med"},{"key":"10.1016\/j.triboint.2018.07.005_bib47","doi-asserted-by":"crossref","first-page":"1210","DOI":"10.1002\/jor.20583","article-title":"The influence of wear paths produced by hip replacement patients during normal walking on wear rates","volume":"26","author":"Bennett","year":"2008","journal-title":"J Orthop Res"},{"key":"10.1016\/j.triboint.2018.07.005_bib48","first-page":"83","article-title":"Ji. Frequency and velocity of people walking - articles - the institution of structural engineers","author":"Aikaterini","year":"2005","journal-title":"Struct Eng"},{"key":"10.1016\/j.triboint.2018.07.005_bib49","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1249\/00005768-198820020-00010","article-title":"Age-related changes in speed of walking","volume":"20","author":"Himann","year":"1988","journal-title":"Med Sci Sports Exerc"},{"key":"10.1016\/j.triboint.2018.07.005_bib50","first-page":"210","article-title":"Basic gait parameters: reference data for normal subjects, 10-79 years of age","volume":"30","author":"Oberg","year":"1993","journal-title":"J Rehabil Res Dev"},{"key":"10.1016\/j.triboint.2018.07.005_bib51","volume":"vol. 2012","author":"ASTM F2025-06","year":"2012"},{"key":"10.1016\/j.triboint.2018.07.005_bib52","doi-asserted-by":"crossref","first-page":"580","DOI":"10.1016\/j.arth.2005.07.009","article-title":"Wear resistance and mechanical properties of highly cross-linked, ultrahigh\u2013molecular weight polyethylene doped with vitamin e","volume":"21","author":"Oral","year":"2006","journal-title":"J Arthroplasty"},{"key":"10.1016\/j.triboint.2018.07.005_bib53","series-title":"Tribology on the small scale: a bottom up approach to friction, lubrication, and wear","author":"Mathew Mate","year":"2008"},{"key":"10.1016\/j.triboint.2018.07.005_bib54","doi-asserted-by":"crossref","DOI":"10.1038\/205386a0","article-title":"Intrinsic viscosity measurements of bovine serum albumin at different temperatures","volume":"205","author":"Chatterjee","year":"1965","journal-title":"Nature"},{"key":"10.1016\/j.triboint.2018.07.005_bib55","first-page":"1463","article-title":"Characteristics of plain and roller bearings","volume":"46","author":"Stribeck","year":"1902","journal-title":"Zeit Ver Deut Ing"},{"key":"10.1016\/j.triboint.2018.07.005_bib56","doi-asserted-by":"crossref","first-page":"514","DOI":"10.1016\/S0043-1648(03)00135-2","article-title":"Effects of contact area and stress on the volumetric wear of ultrahigh molecular weight polyethylene","volume":"254","author":"Mazzucco","year":"2003","journal-title":"Wear"}],"container-title":["Tribology International"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0301679X18303335?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0301679X18303335?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2020,11,5]],"date-time":"2020-11-05T03:24:31Z","timestamp":1604546671000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0301679X18303335"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,11]]},"references-count":56,"alternative-id":["S0301679X18303335"],"URL":"https:\/\/doi.org\/10.1016\/j.triboint.2018.07.005","relation":{},"ISSN":["0301-679X"],"issn-type":[{"value":"0301-679X","type":"print"}],"subject":[],"published":{"date-parts":[[2018,11]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Friction between a polyethylene pin and a microtextured CoCrMo disc, and its correlation to polyethylene wear, as a function of sliding velocity and contact pressure, in the context of metal-on-polyethylene prosthetic hip implants","name":"articletitle","label":"Article Title"},{"value":"Tribology International","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.triboint.2018.07.005","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2018 Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}