{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,26]],"date-time":"2025-09-26T00:02:59Z","timestamp":1758844979973,"version":"3.44.0"},"reference-count":13,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2020,1,1]],"date-time":"2020-01-01T00:00:00Z","timestamp":1577836800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2020,1,1]],"date-time":"2020-01-01T00:00:00Z","timestamp":1577836800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","goldjournal.net","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Urology"],"published-print":{"date-parts":[[2020,1]]},"DOI":"10.1016\/j.urology.2019.09.026","type":"journal-article","created":{"date-parts":[[2019,10,1]],"date-time":"2019-10-01T01:47:28Z","timestamp":1569894448000},"page":"154-158","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":3,"special_numbering":"C","title":["Predictors of Device-related Complications After Exchange of the Pressure-regulating Balloon in Men With an Artificial Urinary Sphincter"],"prefix":"10.1016","volume":"135","author":[{"given":"Jeffrey C.","family":"Loh-Doyle","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Azadeh","family":"Nazemi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Akbar","family":"Ashrafi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Leo R.","family":"Doumanian","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David A.","family":"Ginsberg","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stuart D.","family":"Boyd","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.urology.2019.09.026_bib0001","doi-asserted-by":"crossref","first-page":"681","DOI":"10.1016\/j.eururo.2012.11.034","article-title":"The artificial urinary sphincter after a quarter of a century: a critical systematic review of its use in male non-neurogenic incontinence","volume":"63","author":"Van der Aa","year":"2013","journal-title":"Eur Urol"},{"key":"10.1016\/j.urology.2019.09.026_bib0002","doi-asserted-by":"crossref","first-page":"602","DOI":"10.1016\/j.urology.2015.05.029","article-title":"Long-term outcomes following artificial urinary sphincter placement: an analysis of 1082 cases at mayo clinic","volume":"86","author":"Linder","year":"2015","journal-title":"Urology"},{"key":"10.1016\/j.urology.2019.09.026_bib0003","doi-asserted-by":"crossref","first-page":"759","DOI":"10.1016\/j.juro.2016.08.107","article-title":"Device survival after primary implantation of an artificial urinary sphincter for male stress urinary incontinence","volume":"197","author":"Yafi","year":"2017","journal-title":"J Urol"},{"issue":"Suppl 2","key":"10.1016\/j.urology.2019.09.026_bib0004","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1111\/bju.12207","article-title":"Diagnostic challenges in the evaluation of persistent or recurrent urinary incontinence after artificial urinary sphincter (AUS) implantation in patients after prostatectomy","volume":"112","author":"Chung","year":"2013","journal-title":"BJU Int"},{"key":"10.1016\/j.urology.2019.09.026_bib0005","doi-asserted-by":"crossref","first-page":"252","DOI":"10.1016\/j.urology.2018.07.052","article-title":"Efficacy of pressure regulating balloon exchange in men with post artificial urinary sphincter persistent or recurrent stress urinary incontinence","volume":"123","author":"Moses","year":"2019","journal-title":"Urology"},{"key":"10.1016\/j.urology.2019.09.026_bib0006","doi-asserted-by":"crossref","first-page":"1372","DOI":"10.1016\/S0022-5347(05)65772-2","article-title":"Revision rate after artificial urinary sphincter implantation for incontinence after radical prostatectomy: actuarial analysis","volume":"166","author":"Clemens","year":"2001","journal-title":"J Urol"},{"key":"10.1016\/j.urology.2019.09.026_bib0007","doi-asserted-by":"crossref","first-page":"176","DOI":"10.1016\/j.urology.2015.04.023","article-title":"Revision techniques after artificial urinary sphincter failure in men: results from a multicenter study","volume":"86","author":"Eswara","year":"2015","journal-title":"Urology"},{"key":"10.1016\/j.urology.2019.09.026_bib0008","doi-asserted-by":"crossref","first-page":"1432","DOI":"10.1016\/j.jsxm.2016.06.013","article-title":"Is risk of artificial urethral sphincter cuff erosion higher in patients with penile prosthesis?","volume":"13","author":"Sundaram","year":"2016","journal-title":"J Sex Med"},{"key":"10.1016\/j.urology.2019.09.026_bib0009","doi-asserted-by":"crossref","first-page":"934","DOI":"10.1016\/j.urology.2014.05.043","article-title":"Risk factors for erosion of artificial urinary sphincters: a multicenter prospective study","volume":"84","author":"Brant","year":"2014","journal-title":"Urology"},{"key":"10.1016\/j.urology.2019.09.026_bib0010","doi-asserted-by":"crossref","first-page":"593","DOI":"10.1016\/j.juro.2014.07.115","article-title":"3.5 cm artificial urinary sphincter cuff erosion occurs predominantly in irradiated patients","volume":"193","author":"Simhan","year":"2015","journal-title":"J Urol"},{"key":"10.1016\/j.urology.2019.09.026_bib0011","doi-asserted-by":"crossref","first-page":"1756","DOI":"10.1016\/j.juro.2014.06.088","article-title":"Artificial urinary sphincter placement in compromised urethras and survival: a comparison of virgin, radiated and reoperative cases","volume":"192","author":"McGeady","year":"2014","journal-title":"J Urol"},{"key":"10.1016\/j.urology.2019.09.026_bib0012","doi-asserted-by":"crossref","first-page":"922","DOI":"10.1016\/j.urology.2011.11.051","article-title":"Long-term outcomes after primary failures of artificial urinary sphincter implantation","volume":"79","author":"Wang","year":"2012","journal-title":"Urology"},{"key":"10.1016\/j.urology.2019.09.026_bib0013","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1002\/nau.23825","article-title":"Mechanical failure rates of artificial urinary sphincter components: is the 3.5-cm urethral cuff at higher risk?","volume":"38","author":"Loh-Doyle","year":"2019","journal-title":"Neurourol Urodyn"}],"container-title":["Urology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0090429519308556?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0090429519308556?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,25]],"date-time":"2025-09-25T02:04:25Z","timestamp":1758765865000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0090429519308556"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,1]]},"references-count":13,"alternative-id":["S0090429519308556"],"URL":"https:\/\/doi.org\/10.1016\/j.urology.2019.09.026","relation":{},"ISSN":["0090-4295"],"issn-type":[{"type":"print","value":"0090-4295"}],"subject":[],"published":{"date-parts":[[2020,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Predictors of Device-related Complications After Exchange of the Pressure-regulating Balloon in Men With an Artificial Urinary Sphincter","name":"articletitle","label":"Article Title"},{"value":"Urology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.urology.2019.09.026","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2019 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}