{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,20]],"date-time":"2026-10-20T07:58:00Z","timestamp":1792483080744,"version":"4.5.0"},"reference-count":24,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,3,1]],"date-time":"2026-03-01T00:00:00Z","timestamp":1772323200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,3,1]],"date-time":"2026-03-01T00:00:00Z","timestamp":1772323200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,3,1]],"date-time":"2026-03-01T00:00:00Z","timestamp":1772323200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-017"},{"start":{"date-parts":[[2026,3,1]],"date-time":"2026-03-01T00:00:00Z","timestamp":1772323200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"},{"start":{"date-parts":[[2026,3,1]],"date-time":"2026-03-01T00:00:00Z","timestamp":1772323200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-012"},{"start":{"date-parts":[[2026,3,1]],"date-time":"2026-03-01T00:00:00Z","timestamp":1772323200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2026,3,1]],"date-time":"2026-03-01T00:00:00Z","timestamp":1772323200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-004"}],"funder":[{"DOI":"10.13039\/100000001","name":"National Science Foundation","doi-asserted-by":"publisher","award":["ECCS-2025064"],"award-info":[{"award-number":["ECCS-2025064"]}],"id":[{"id":"10.13039\/100000001","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","goldjournal.net","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Urology"],"published-print":{"date-parts":[[2026,3]]},"DOI":"10.1016\/j.urology.2025.12.031","type":"journal-article","created":{"date-parts":[[2025,12,19]],"date-time":"2025-12-19T17:04:15Z","timestamp":1766163855000},"page":"128-133","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":2,"special_numbering":"C","title":["Time Dependent Material Fatigue of the Artificial Urinary Sphincter Pressure-regulating Balloon: A Mechanical and Microscopic Analysis"],"prefix":"10.1016","volume":"209","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2091-7425","authenticated-orcid":false,"given":"Matthew J.","family":"Salvino","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas E.","family":"Schroeder","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Logan W.","family":"Grimaud","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrew C.","family":"Peterson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.urology.2025.12.031_bib1","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1016\/j.eururo.2011.07.049","article-title":"Urinary incontinence and its relationship to mental health and health-related quality of life in men and women in Sweden, the United Kingdom, and the United States","volume":"61","author":"Coyne","year":"2012","journal-title":"Eur Urol"},{"key":"10.1016\/j.urology.2025.12.031_bib2","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1097\/JU.0000000000000314","article-title":"Incontinence after prostate treatment: AUA\/SUFU guideline","volume":"202","author":"Sandhu","year":"2019","journal-title":"J Urol"},{"key":"10.1016\/j.urology.2025.12.031_bib3","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1016\/j.sxmr.2015.11.004","article-title":"Contemporary review of artificial urinary sphincters for male stress urinary incontinence","volume":"4","author":"Yafi","year":"2016","journal-title":"Sex Med Rev"},{"key":"10.1016\/j.urology.2025.12.031_bib4","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1016\/j.urology.2017.09.025","article-title":"Management of postradical prostatectomy urinary incontinence: a review","volume":"113","author":"Radadia","year":"2018","journal-title":"Urology"},{"key":"10.1016\/j.urology.2025.12.031_bib5","doi-asserted-by":"crossref","first-page":"985","DOI":"10.1016\/j.eururo.2011.03.020","article-title":"Contemporary management of postprostatectomy incontinence","volume":"59","author":"Bauer","year":"2011","journal-title":"Eur Urol"},{"key":"10.1016\/j.urology.2025.12.031_bib6","doi-asserted-by":"crossref","first-page":"838","DOI":"10.1016\/j.juro.2016.03.076","article-title":"Long-term quality of life and functional outcomes among primary and secondary artificial urinary sphincter implantations in men with stress urinary incontinence","volume":"196","author":"Viers","year":"2016","journal-title":"J Urol"},{"key":"10.1016\/j.urology.2025.12.031_bib7","doi-asserted-by":"crossref","first-page":"602","DOI":"10.1016\/j.urology.2015.05.029","article-title":"Long-term outcomes following artificial urinary sphincter placement: an analysis of 1082 cases at Mayo Clinic","volume":"86","author":"Linder","year":"2015","journal-title":"Urology"},{"key":"10.1016\/j.urology.2025.12.031_bib8","doi-asserted-by":"crossref","first-page":"669","DOI":"10.1111\/bju.13324","article-title":"Urethral atrophy after implantation of an artificial urinary sphincter: fact or fiction?","volume":"117","author":"Bugeja","year":"2016","journal-title":"BJU Int"},{"key":"10.1016\/j.urology.2025.12.031_bib9","doi-asserted-by":"crossref","first-page":"887","DOI":"10.1016\/j.euf.2018.02.014","article-title":"Causes of artificial urinary sphincter failure and strategies for surgical revision: implications of device component survival","volume":"5","author":"Srivastava","year":"2019","journal-title":"Eur Urol Focus"},{"key":"10.1016\/j.urology.2025.12.031_bib10","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1007\/s11934-017-0666-y","article-title":"A systematic approach to the evaluation and management of the failed artificial urinary sphincter","volume":"18","author":"Dobberfuhl","year":"2017","journal-title":"Curr Urol Rep"},{"key":"10.1016\/j.urology.2025.12.031_bib11","doi-asserted-by":"crossref","first-page":"244","DOI":"10.1016\/j.urology.2023.10.008","article-title":"Characterizing and quantifying material fatigue of the artificial urinary sphincter pressure regulating balloon","volume":"183","author":"Krughoff","year":"2024","journal-title":"Urology"},{"key":"10.1016\/j.urology.2025.12.031_bib12","series-title":"Statics and Mechanics of Materials","author":"Hibbeler","year":"2016"},{"key":"10.1016\/j.urology.2025.12.031_bib13","doi-asserted-by":"crossref","first-page":"1131","DOI":"10.1590\/s1677-5538.ibju.2020.1122","article-title":"The male sling for stress urinary incontinence: tips and tricks for success","volume":"47","author":"Inouye","year":"2021","journal-title":"Int Braz J Urol"},{"key":"10.1016\/j.urology.2025.12.031_bib14","doi-asserted-by":"crossref","first-page":"1242","DOI":"10.1097\/01.ju.0000152315.91444.d0","article-title":"Outcomes following revisions and secondary implantation of the artificial urinary sphincter","volume":"173","author":"Raj","year":"2005","journal-title":"J Urol"},{"key":"10.1016\/j.urology.2025.12.031_bib15","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1002\/nau.23825","article-title":"Mechanical failure rates of artificial urinary sphincter components: Is the 3.5-cm urethral cuff at higher risk?","volume":"38","author":"Loh-Doyle","year":"2019","journal-title":"Neurourol Urodyn"},{"key":"10.1016\/j.urology.2025.12.031_bib16","doi-asserted-by":"crossref","first-page":"146","DOI":"10.1111\/iju.13485","article-title":"Can time to failure predict the faulty component in artificial urinary sphincter device malfunctions?","volume":"25","author":"Yang","year":"2018","journal-title":"Int J Urol"},{"key":"10.1016\/j.urology.2025.12.031_bib17","doi-asserted-by":"crossref","first-page":"1523","DOI":"10.1016\/j.juro.2015.10.084","article-title":"Artificial urinary sphincter mechanical failures-is it better to replace the entire device or just the malfunctioning component?","volume":"195","author":"Linder","year":"2016","journal-title":"J Urol"},{"key":"10.1016\/j.urology.2025.12.031_bib18","doi-asserted-by":"crossref","first-page":"922","DOI":"10.1016\/j.urology.2011.11.051","article-title":"Long-term outcomes after primary failures of artificial urinary sphincter implantation","volume":"79","author":"Wang","year":"2012","journal-title":"Urology"},{"key":"10.1016\/j.urology.2025.12.031_bib19","doi-asserted-by":"crossref","first-page":"176","DOI":"10.1016\/j.urology.2015.04.023","article-title":"Revision techniques after artificial urinary sphincter failure in men: results from a multicenter study","volume":"86","author":"Eswara","year":"2015","journal-title":"Urology"},{"key":"10.1016\/j.urology.2025.12.031_bib20","doi-asserted-by":"crossref","first-page":"252","DOI":"10.1016\/j.urology.2018.07.052","article-title":"Efficacy of pressure regulating balloon exchange in men with post artificial urinary sphincter persistent or recurrent stress urinary incontinence","volume":"123","author":"Moses","year":"2019","journal-title":"Urology"},{"key":"10.1016\/j.urology.2025.12.031_bib21","doi-asserted-by":"crossref","first-page":"188","DOI":"10.1016\/j.urology.2020.01.036","article-title":"Pressure regulating balloon herniation: a correctable cause of artificial urinary sphincter malfunction","volume":"139","author":"Khouri","year":"2020","journal-title":"Urology"},{"key":"10.1016\/j.urology.2025.12.031_bib22","series-title":"Fundamentals of Materials Science and Engineering","author":"Callister","year":"2001"},{"key":"10.1016\/j.urology.2025.12.031_bib23","doi-asserted-by":"crossref","first-page":"1043","DOI":"10.1016\/j.juro.2015.05.075","article-title":"The Ohmmeter identifies the site of fluid leakage during artificial urinary sphincter revision surgery","volume":"194","author":"Selph","year":"2015","journal-title":"J Urol"},{"key":"10.1016\/j.urology.2025.12.031_bib24","doi-asserted-by":"crossref","first-page":"742","DOI":"10.1097\/JU.0000000000003138","article-title":"Artificial urinary sphincter cuff downsizing improves continence and patient satisfaction in cases of sub-cuff atrophy","volume":"209","author":"Krughoff","year":"2023","journal-title":"J Urol"}],"container-title":["Urology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0090429525014013?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0090429525014013?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,3,16]],"date-time":"2026-03-16T06:17:25Z","timestamp":1773641845000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0090429525014013"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3]]},"references-count":24,"alternative-id":["S0090429525014013"],"URL":"https:\/\/doi.org\/10.1016\/j.urology.2025.12.031","relation":{},"ISSN":["0090-4295"],"issn-type":[{"value":"0090-4295","type":"print"}],"subject":[],"published":{"date-parts":[[2026,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Time Dependent Material Fatigue of the Artificial Urinary Sphincter Pressure-regulating Balloon: A Mechanical and Microscopic Analysis","name":"articletitle","label":"Article Title"},{"value":"Urology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.urology.2025.12.031","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 Elsevier Inc. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}]}}