{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T01:43:36Z","timestamp":1791855816998,"version":"4.3.4"},"reference-count":24,"publisher":"Elsevier BV","issue":"5","license":[{"start":{"date-parts":[[2023,9,1]],"date-time":"2023-09-01T00:00:00Z","timestamp":1693526400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2023,9,1]],"date-time":"2023-09-01T00:00:00Z","timestamp":1693526400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["vaajournal.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Veterinary Anaesthesia and Analgesia"],"published-print":{"date-parts":[[2023,9]]},"DOI":"10.1016\/j.vaa.2023.06.002","type":"journal-article","created":{"date-parts":[[2023,6,15]],"date-time":"2023-06-15T18:38:41Z","timestamp":1686854321000},"page":"408-414","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":2,"title":["Evaluation of a three-axial acceleromyography monitor in dogs compared with mechanomyography"],"prefix":"10.1016","volume":"50","author":[{"given":"Chia T.","family":"Tseng","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel M.","family":"Sakai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9799-4499","authenticated-orcid":false,"given":"Augusto M.","family":"Lorenzutti","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Manuel","family":"Martin-Flores","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.vaa.2023.06.002_bib1","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","article-title":"Statistical methods for assessing agreement between two methods of clinical measurement","volume":"1","author":"Bland","year":"1986","journal-title":"Lancet"},{"key":"10.1016\/j.vaa.2023.06.002_bib2","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1111\/anae.14872","article-title":"A\u00a0comparison of a prototype electromyograph vs. a mechanomyograph and an acceleromyograph for assessment of neuromuscular blockade","volume":"75","author":"Bowdle","year":"2020","journal-title":"Anaesth"},{"key":"10.1016\/j.vaa.2023.06.002_bib3","doi-asserted-by":"crossref","first-page":"712","DOI":"10.1016\/j.bja.2020.02.022","article-title":"Counting train-of-four twitch response: comparison of palpation to mechanomyography, acceleromyography, and electromyography","volume":"124","author":"Bowdle","year":"2020","journal-title":"Br J Anaesth"},{"key":"10.1016\/j.vaa.2023.06.002_bib4","doi-asserted-by":"crossref","first-page":"629","DOI":"10.1097\/00000542-199004000-00009","article-title":"Stimulation with submaximal current for train-of-four monitoring","volume":"72","author":"Brull","year":"1990","journal-title":"Anesthesiology"},{"key":"10.1016\/j.vaa.2023.06.002_bib5","doi-asserted-by":"crossref","first-page":"1119","DOI":"10.1097\/00000542-200405000-00013","article-title":"Can acceleromyography detect low levels of residual paralysis? A probability approach to detect a mechanomyographic train-of-four ratio of 0.9","volume":"100","author":"Capron","year":"2004","journal-title":"Anesthesiology"},{"key":"10.1016\/j.vaa.2023.06.002_bib6","doi-asserted-by":"crossref","first-page":"449","DOI":"10.1111\/j.1399-6576.2008.01866.x","article-title":"Acceleromyography and mechanomyography for establishing potency of neuromuscular blocking agents: a randomized-controlled trial","volume":"53","author":"Claudius","year":"2009","journal-title":"Acta Anaesthesiol Scand"},{"key":"10.1016\/j.vaa.2023.06.002_bib7","doi-asserted-by":"crossref","first-page":"1261","DOI":"10.1097\/ALN.0b013e3181a4f239","article-title":"Is the performance of acceleromyography improved with preload and normalization? A comparison with mechanomyography","volume":"110","author":"Claudius","year":"2009","journal-title":"Anesthesiology"},{"key":"10.1016\/j.vaa.2023.06.002_bib8","doi-asserted-by":"crossref","first-page":"310","DOI":"10.1093\/bja\/aeq162","article-title":"Arm-to-arm variation when evaluating neuromuscular block: an analysis of the precision and the bias and agreement between arms when using mechanomyography or acceleromyography","volume":"105","author":"Claudius","year":"2010","journal-title":"Br J Anaesth"},{"key":"10.1016\/j.vaa.2023.06.002_bib9","doi-asserted-by":"crossref","first-page":"1117","DOI":"10.1097\/ALN.0b013e318173f62f","article-title":"Acceleromyography for use in scientific and clinical practice: a systematic review of the evidence","volume":"108","author":"Claudius","year":"2008","journal-title":"Anesthesiology"},{"key":"10.1016\/j.vaa.2023.06.002_bib10","first-page":"283","article-title":"Comparative pharmacodynamics of pancuronium, cisatracurium, and CW002 in rabbits","volume":"53","author":"Diaz","year":"2014","journal-title":"J\u00a0Am Assoc Lab Anim Sci"},{"key":"10.1016\/j.vaa.2023.06.002_bib11","doi-asserted-by":"crossref","first-page":"274","DOI":"10.1093\/bja\/62.3.274","article-title":"Double burst stimulation (DBS): a new pattern of nerve stimulation to identify residual neuromuscular block","volume":"62","author":"Engbaek","year":"1989","journal-title":"Br J Anaesth"},{"key":"10.1016\/j.vaa.2023.06.002_bib12","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1034\/j.1399-6576.2002.460216.x","article-title":"Postoperative muscle paralysis after rocuronium: less residual block when acceleromyography is used","volume":"46","author":"G\u00e4tke","year":"2002","journal-title":"Acta Anaesthesiol Scand"},{"key":"10.1016\/j.vaa.2023.06.002_bib13","doi-asserted-by":"crossref","first-page":"316","DOI":"10.1111\/j.1399-6576.2005.00643.x","article-title":"Acceleromyography vs. electromyography: An ipsilateral comparison of the indirectly evoked neuromuscular response to train-of-four stimulation","volume":"49","author":"Kopman","year":"2005","journal-title":"Acta Anaesthesiol Scand"},{"key":"10.1016\/j.vaa.2023.06.002_bib14","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1213\/ANE.0b013e3182937fc4","article-title":"An ipsilateral comparison of acceleromyography and electromyography during recovery from nondepolarizing neuromuscular block under general anesthesia in humans","volume":"117","author":"Liang","year":"2013","journal-title":"Anesth Analg"},{"key":"10.1016\/j.vaa.2023.06.002_bib15","doi-asserted-by":"crossref","first-page":"1315","DOI":"10.1097\/JTO.0b013e3181ec173d","article-title":"Receiver operating characteristic curve in diagnostic test assessment","volume":"5","author":"Mandrekar","year":"2010","journal-title":"J\u00a0Thorac Oncol"},{"key":"10.1016\/j.vaa.2023.06.002_bib16","doi-asserted-by":"crossref","first-page":"182","DOI":"10.1016\/j.vaa.2019.01.002","article-title":"Can we see fade? A survey of anesthesia providers and our ability to detect partial neuromuscular block in dogs","volume":"46","author":"Martin-Flores","year":"2019","journal-title":"Vet Anaesth Analg"},{"key":"10.1016\/j.vaa.2023.06.002_bib17","doi-asserted-by":"crossref","first-page":"330","DOI":"10.1111\/j.1475-1313.2011.00851.x","article-title":"Statistical methods for conducting agreement (comparison of clinical tests) and precision (repeatability or reproducibility) studies in optometry and ophthalmology","volume":"31","author":"McAlinden","year":"2011","journal-title":"Ophthalmic Physiol Opt"},{"key":"10.1016\/j.vaa.2023.06.002_bib18","doi-asserted-by":"crossref","first-page":"946","DOI":"10.1097\/ALN.0b013e3182342840","article-title":"Intraoperative acceleromyography monitoring reduces symptoms of muscle weakness and improves quality of recovery in the early postoperative period","volume":"115","author":"Murphy","year":"2011","journal-title":"Anesthesiology"},{"key":"10.1016\/j.vaa.2023.06.002_bib19","doi-asserted-by":"crossref","first-page":"389","DOI":"10.1097\/ALN.0b013e318182af3b","article-title":"Intraoperative acceleromyographic monitoring reduces the risk of residual neuromuscular blockade and adverse respiratory events in the postanesthesia care unit","volume":"109","author":"Murphy","year":"2008","journal-title":"Anesthesiology"},{"key":"10.1016\/j.vaa.2023.06.002_bib20","doi-asserted-by":"crossref","first-page":"3617","DOI":"10.1111\/bph.15193","article-title":"The ARRIVE guidelines 2.0: Updated guidelines for reporting animal research","volume":"177","author":"Percie du Sert","year":"2020","journal-title":"Br J Pharmacol"},{"key":"10.1016\/j.vaa.2023.06.002_bib21","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1111\/vaa.12197","article-title":"Differences between acceleromyography and electromyography during neuromuscular function monitoring in anesthetized Beagle dogs","volume":"42","author":"Sakai","year":"2015","journal-title":"Vet Anaesth Analg"},{"key":"10.1016\/j.vaa.2023.06.002_bib22","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1016\/j.tvjl.2017.12.020","article-title":"Bias, limits of agreement, and percent errors between acceleromyography and mechanomyography in anesthetized dogs","volume":"233","author":"Sakai","year":"2018","journal-title":"Vet J"},{"key":"10.1016\/j.vaa.2023.06.002_bib23","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1097\/ALN.0000000000004379","article-title":"2023 American Society of Anesthesiologists Practice Guidelines for monitoring and antagonism of neuromuscular blockade: a report by the American Society of Anesthesiologists Task Force on Neuromuscular Blockade","volume":"138","author":"Thilen","year":"2023","journal-title":"Anesthesiology"},{"key":"10.1016\/j.vaa.2023.06.002_bib24","first-page":"403","article-title":"Double burst stimulation with submaximal current","volume":"11","author":"Ueda","year":"1994","journal-title":"Eur J Anaesthesiol"}],"container-title":["Veterinary Anaesthesia and Analgesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1467298723001022?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1467298723001022?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,26]],"date-time":"2025-10-26T02:59:53Z","timestamp":1761447593000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1467298723001022"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,9]]},"references-count":24,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2023,9]]}},"alternative-id":["S1467298723001022"],"URL":"https:\/\/doi.org\/10.1016\/j.vaa.2023.06.002","relation":{},"ISSN":["1467-2987"],"issn-type":[{"value":"1467-2987","type":"print"}],"subject":[],"published":{"date-parts":[[2023,9]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Evaluation of a three-axial acceleromyography monitor in dogs compared with mechanomyography","name":"articletitle","label":"Article Title"},{"value":"Veterinary Anaesthesia and Analgesia","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.vaa.2023.06.002","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2023 Association of Veterinary Anaesthetists and American College of Veterinary Anesthesia and Analgesia. Published by Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}