{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,3]],"date-time":"2026-11-03T21:28:10Z","timestamp":1793741290389,"version":"4.6.1"},"reference-count":19,"publisher":"Elsevier BV","issue":"6","license":[{"start":{"date-parts":[[2026,11,1]],"date-time":"2026-11-01T00:00:00Z","timestamp":1793491200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,11,1]],"date-time":"2026-11-01T00:00:00Z","timestamp":1793491200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,8,8]],"date-time":"2026-08-08T00:00:00Z","timestamp":1786147200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Veterinary Anaesthesia and Analgesia"],"published-print":{"date-parts":[[2026,11]]},"DOI":"10.1016\/j.vaa.2026.101297","type":"journal-article","created":{"date-parts":[[2026,8,12]],"date-time":"2026-08-12T15:37:40Z","timestamp":1786549060000},"page":"101297","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Evaluation of an anaesthetic conserving device in semi-closed rebreathing systems using an artificial lung with isoflurane and sevoflurane: an in vitro pilot study"],"prefix":"10.1016","volume":"53","author":[{"ORCID":"https:\/\/orcid.org\/0009-0004-1448-0022","authenticated-orcid":false,"given":"Jana","family":"Flyps","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6381-590X","authenticated-orcid":false,"given":"Maarten","family":"Haspeslagh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefaan","family":"Bouchez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7105-6517","authenticated-orcid":false,"given":"Stijn","family":"Schauvliege","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.vaa.2026.101297_bib1","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1007\/s10877-020-00634-4","article-title":"In vitro performance evaluation of AnaConDaTM-100 and AnaConDaTM-50 compared to a circle breathing system for control and consumption of volatile anaesthetics","volume":"36","author":"Bellgardt","year":"2022","journal-title":"J. Clin. Monit. Comput."},{"key":"10.1016\/j.vaa.2026.101297_bib2","doi-asserted-by":"crossref","first-page":"371","DOI":"10.1213\/ANE.0000000000003452","article-title":"Halving the volume of AnaConDa: evaluation of a new small-volume anesthetic reflector in a test lung model","volume":"129","author":"Bomberg","year":"2019","journal-title":"Anesth. Analg."},{"key":"10.1016\/j.vaa.2026.101297_bib3","doi-asserted-by":"crossref","first-page":"506","DOI":"10.1034\/j.1399-6576.2002.460506.x","article-title":"The sevoflurane saving capacity of a new anaesthetic agent conserving device compared with a low flow circle system","volume":"46","author":"Enlund","year":"2002","journal-title":"Acta Anaesthesiol. Scand."},{"key":"10.1016\/j.vaa.2026.101297_bib4","doi-asserted-by":"crossref","first-page":"429","DOI":"10.1046\/j.1365-2044.2001.01900.x","article-title":"A new device to reduce the consumption of a halogenated anaesthetic agent","volume":"56","author":"Enlund","year":"2001","journal-title":"Anaesthesia"},{"key":"10.1016\/j.vaa.2026.101297_bib5","doi-asserted-by":"crossref","first-page":"595","DOI":"10.1007\/s10877-017-0097-9","article-title":"A technical review of the history, development and performance of the anaesthetic conserving device \"AnaConDa\" for delivering volatile anaesthetic in intensive and post-operative critical care","volume":"32","author":"Farrell","year":"2018","journal-title":"J. Clin. Monit. Comput."},{"key":"10.1016\/j.vaa.2026.101297_bib6","doi-asserted-by":"crossref","first-page":"172","DOI":"10.1111\/eve.13752","article-title":"Sustainable development in equine anaesthesia","volume":"35","author":"Haseler","year":"2022","journal-title":"Equine Vet. Educ."},{"key":"10.1016\/j.vaa.2026.101297_bib7","doi-asserted-by":"crossref","first-page":"593","DOI":"10.1007\/s10877-018-0172-x","article-title":"Sedation with inhaled agents in the ICU: what are we waiting for?","volume":"32","author":"Hendrickx","year":"2018","journal-title":"J. Clin. Monit. Comput."},{"key":"10.1016\/j.vaa.2026.101297_bib8","doi-asserted-by":"crossref","first-page":"409","DOI":"10.1016\/j.vaa.2018.12.008","article-title":"Environmental sustainability in veterinary anaesthesia","volume":"46","author":"Jones","year":"2019","journal-title":"Vet. Anaesth. Analg."},{"key":"10.1016\/j.vaa.2026.101297_bib9","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1080\/17434440.2021.1865151","article-title":"Reflection efficiencies of AnaConDa-S and AnaConDa-100 for isoflurane under dry laboratory and simulated clinical conditions: a bench study using a test lung","volume":"18","author":"Kermad","year":"2021","journal-title":"Expert Rev. Med. Devices"},{"key":"10.1016\/j.vaa.2026.101297_bib10","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1007\/s10877-008-9158-4","article-title":"Technical performance and reflection capacity of the anaesthetic conserving device\u2014a bench study with isoflurane and sevoflurane","volume":"23","author":"Meiser","year":"2009","journal-title":"J. Clin. Monit. Comput."},{"key":"10.1016\/j.vaa.2026.101297_bib11","doi-asserted-by":"crossref","first-page":"523","DOI":"10.1016\/j.bpa.2005.02.006","article-title":"Inhalational anaesthetics in the ICU: theory and practice of inhalational sedation in the ICU, economics, risk-benefit","volume":"19","author":"Meiser","year":"2005","journal-title":"Best Pract. Res. Clin. Anaesthesiol."},{"key":"10.1016\/j.vaa.2026.101297_bib12","doi-asserted-by":"crossref","first-page":"919","DOI":"10.1007\/s10877-022-00967-2","article-title":"Increasing the reflection efficiency of the Sedaconda ACD-S by heating and cooling the anaesthetic reflector: a bench study using a test lung","volume":"37","author":"Meiser","year":"2023","journal-title":"J. Clin. Monit. Comput."},{"key":"10.1016\/j.vaa.2026.101297_bib13","doi-asserted-by":"crossref","first-page":"585","DOI":"10.1097\/01.CCM.0000156294.92415.E2","article-title":"Ambient isoflurane pollution and isoflurane consumption during intensive care unit sedation with the Anesthetic Conserving Device","volume":"33","author":"Sackey","year":"2005","journal-title":"Crit. Care Med."},{"key":"10.1016\/j.vaa.2026.101297_bib14","doi-asserted-by":"crossref","first-page":"101","DOI":"10.4103\/mgr.MEDGASRES-D-23-00059","article-title":"Anesthesia and its environmental impact: approaches to minimize exposure to anesthetic gases and reduce waste","volume":"15","author":"Samad","year":"2024","journal-title":"Med. Gas Res."},{"key":"10.1016\/j.vaa.2026.101297_bib15","doi-asserted-by":"crossref","first-page":"230","DOI":"10.1111\/j.1467-2995.2009.00453.x","article-title":"Influence of two different ventilation modes on the function of an anaesthetic conserving device in sevoflurane anaesthetized piglets","volume":"36","author":"Schauvliege","year":"2009","journal-title":"Vet. Anaesth. Analg"},{"key":"10.1016\/j.vaa.2026.101297_bib16","doi-asserted-by":"crossref","first-page":"1081","DOI":"10.1213\/ANE.0b013e31824d6150","article-title":"Medical intelligence article: assessing the impact on global climate from general anesthetic gases","volume":"114","author":"Sulbaek Andersen","year":"2012","journal-title":"Anesth. Analg."},{"key":"10.1016\/j.vaa.2026.101297_bib17","doi-asserted-by":"crossref","first-page":"1056","DOI":"10.1213\/01.ANE.0000050558.89090.95","article-title":"The anesthetic conserving device compared with conventional circle system used under different flow conditions for inhaled anesthesia","volume":"96","author":"Tempia","year":"2003","journal-title":"Anesth. Analg."},{"key":"10.1016\/j.vaa.2026.101297_bib18","doi-asserted-by":"crossref","first-page":"826","DOI":"10.1213\/ANE.0000000000005504","article-title":"Environmental and occupational considerations of anesthesia: a narrative review and update","volume":"133","author":"Varughese","year":"2021","journal-title":"Anesth. Analg."},{"key":"10.1016\/j.vaa.2026.101297_bib19","first-page":"160","article-title":"Total intravenous anesthesia in dogs. Vlaams Diergeneeskd","volume":"78","author":"Waelbers","year":"2009","journal-title":"Tijdschr."}],"container-title":["Veterinary Anaesthesia and Analgesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S146729872600111X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S146729872600111X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,11,3]],"date-time":"2026-11-03T20:33:57Z","timestamp":1793738037000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S146729872600111X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,11]]},"references-count":19,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2026,11]]}},"alternative-id":["S146729872600111X"],"URL":"https:\/\/doi.org\/10.1016\/j.vaa.2026.101297","relation":{},"ISSN":["1467-2987"],"issn-type":[{"value":"1467-2987","type":"print"}],"subject":[],"published":{"date-parts":[[2026,11]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Evaluation of an anaesthetic conserving device in semi-closed rebreathing systems using an artificial lung with isoflurane and sevoflurane: an in vitro pilot study","name":"articletitle","label":"Article Title"},{"value":"Veterinary Anaesthesia and Analgesia","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.vaa.2026.101297","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 The Author(s). Published by Elsevier Ltd on behalf of Association of Veterinary Anaesthetists and American College of Veterinary Anesthesia and Analgesia.","name":"copyright","label":"Copyright"}],"article-number":"101297"}}