{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,28]],"date-time":"2026-10-28T17:36:05Z","timestamp":1793208965218,"version":"4.5.0"},"reference-count":16,"publisher":"Elsevier BV","issue":"6","license":[{"start":{"date-parts":[[2026,11,1]],"date-time":"2026-11-01T00:00:00Z","timestamp":1793491200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,11,1]],"date-time":"2026-11-01T00:00:00Z","timestamp":1793491200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,9,12]],"date-time":"2026-09-12T00:00:00Z","timestamp":1789171200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Veterinary Anaesthesia and Analgesia"],"published-print":{"date-parts":[[2026,11]]},"DOI":"10.1016\/j.vaa.2026.101370","type":"journal-article","created":{"date-parts":[[2026,9,22]],"date-time":"2026-09-22T16:51:51Z","timestamp":1790095911000},"page":"101370","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Combining an anaesthetic conserving device with a circle breathing system to minimise isoflurane waste: an in vitro study"],"prefix":"10.1016","volume":"53","author":[{"ORCID":"https:\/\/orcid.org\/0009-0004-1448-0022","authenticated-orcid":false,"given":"Jana","family":"Flyps","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6381-590X","authenticated-orcid":false,"given":"Maarten","family":"Haspeslagh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefaan","family":"Bouchez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jan F.A.","family":"Hendrickx","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6569-7003","authenticated-orcid":false,"given":"Andreas","family":"Meiser","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7105-6517","authenticated-orcid":false,"given":"Stijn","family":"Schauvliege","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.vaa.2026.101370_bib1","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1007\/s10877-020-00634-4","article-title":"In vitro performance evaluation of AnaConDaTM-100 and AnaConDaTM-50 compared to a circle breathing system for control and consumption of volatile anaesthetics","volume":"36","author":"Bellgardt","year":"2022","journal-title":"J. Clin. Monit. Comput."},{"key":"10.1016\/j.vaa.2026.101370_bib2","doi-asserted-by":"crossref","first-page":"371","DOI":"10.1213\/ANE.0000000000003452","article-title":"Halving the volume of AnaConDa: evaluation of a new small-volume anesthetic reflector in a test lung model","volume":"129","author":"Bomberg","year":"2019","journal-title":"Anesth. Analg."},{"key":"10.1016\/j.vaa.2026.101370_bib3","doi-asserted-by":"crossref","first-page":"506","DOI":"10.1034\/j.1399-6576.2002.460506.x","article-title":"The sevoflurane saving capacity of a new anaesthetic agent conserving device compared with a low flow circle system","volume":"46","author":"Enlund","year":"2002","journal-title":"Acta Anaesthesiol. Scand."},{"key":"10.1016\/j.vaa.2026.101370_bib4","doi-asserted-by":"crossref","first-page":"429","DOI":"10.1046\/j.1365-2044.2001.01900.x","article-title":"A new device to reduce the consumption of a halogenated anaesthetic agent","volume":"56","author":"Enlund","year":"2001","journal-title":"Anaesthesia"},{"key":"10.1016\/j.vaa.2026.101370_bib5","doi-asserted-by":"crossref","first-page":"595","DOI":"10.1007\/s10877-017-0097-9","article-title":"A technical review of the history, development and performance of the anaesthetic conserving device \u201cAnaConDa\u201d for delivering volatile anaesthetic in intensive and post-operative critical care","volume":"32","author":"Farrell","year":"2018","journal-title":"J. Clin. Monit. Comput."},{"key":"10.1016\/j.vaa.2026.101370_bib6","doi-asserted-by":"crossref","first-page":"593","DOI":"10.1007\/s10877-018-0172-x","article-title":"Sedation with inhaled agents in the ICU: what are we waiting for?","volume":"32","author":"Hendrickx","year":"2018","journal-title":"J. Clin. Monit. Comput."},{"key":"10.1016\/j.vaa.2026.101370_bib18","article-title":"Evaluation of an anaesthetic conserving device in semi-closed rebreathing systems using an artificial lung with isoflurane and sevoflurane: an in vitro pilot study","author":"Flyps","year":"2026","journal-title":"Vet. Anaesth. Analg."},{"key":"10.1016\/j.vaa.2026.101370_bib8","doi-asserted-by":"crossref","first-page":"1042","DOI":"10.1213\/ANE.0000000000005074","article-title":"Reflection versus rebreathing for administration of sevoflurane during minor gynecological surgery","volume":"132","author":"Kermad","year":"2021","journal-title":"Anesth. Analg."},{"key":"10.1016\/j.vaa.2026.101370_bib9","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1080\/17434440.2021.1865151","article-title":"Reflection efficiencies of AnaConDa-S and AnaConDa-100 for isoflurane under dry laboratory and simulated clinical conditions: a bench study using a test lung","volume":"18","author":"Kermad","year":"2021","journal-title":"Expert Rev. Med. Devices"},{"key":"10.1016\/j.vaa.2026.101370_bib17","doi-asserted-by":"crossref","first-page":"1152","DOI":"10.1213\/00000539-199406000-00022","article-title":"Specific Gravities of Desflurane, Enflurane, Halothane, Isoflurane, and Sevoflurane","volume":"78","author":"Laster","year":"1994","journal-title":"Anesth Analg"},{"key":"10.1016\/j.vaa.2026.101370_bib10","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1007\/s10877-008-9158-4","article-title":"Technical performance and reflection capacity of the anaesthetic conserving device - A bench study with isoflurane and sevoflurane","volume":"23","author":"Meiser","year":"2009","journal-title":"J. Clin. Monit. Comput."},{"key":"10.1016\/j.vaa.2026.101370_bib11","doi-asserted-by":"crossref","first-page":"523","DOI":"10.1016\/j.bpa.2005.02.006","article-title":"Inhalational anaesthetics in the ICU: theory and practice of inhalational sedation in the ICU, economics, risk-benefit","volume":"19","author":"Meiser","year":"2005","journal-title":"Best Pract. Res. Clin. Anaesthesiol."},{"key":"10.1016\/j.vaa.2026.101370_bib12","doi-asserted-by":"crossref","first-page":"2241","DOI":"10.1097\/01.CCM.0000145951.76082.77","article-title":"Prolonged isoflurane sedation of intensive care unit patients with the Anesthetic Conserving Device","volume":"32","author":"Sackey","year":"2004","journal-title":"Crit. Care Med."},{"key":"10.1016\/j.vaa.2026.101370_bib13","doi-asserted-by":"crossref","first-page":"585","DOI":"10.1097\/01.CCM.0000156294.92415.E2","article-title":"Ambient isoflurane pollution and isoflurane consumption during intensive care unit sedation with the Anesthetic Conserving Device","volume":"33","author":"Sackey","year":"2005","journal-title":"Crit. Care Med."},{"key":"10.1016\/j.vaa.2026.101370_bib14","doi-asserted-by":"crossref","first-page":"230","DOI":"10.1111\/j.1467-2995.2009.00453.x","article-title":"Influence of two different ventilation modes on the function of an anaesthetic conserving device in sevoflurane anaesthetized piglets","volume":"36","author":"Schauvliege","year":"2009","journal-title":"Vet. Anaesth. Analg"},{"key":"10.1016\/j.vaa.2026.101370_bib15","doi-asserted-by":"crossref","first-page":"1056","DOI":"10.1213\/01.ANE.0000050558.89090.95","article-title":"The anesthetic conserving device compared with conventional circle system used under different flow conditions for inhaled anesthesia","volume":"96","author":"Tempia","year":"2003","journal-title":"Anesth. Analg."}],"container-title":["Veterinary Anaesthesia and Analgesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1467298726001844?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1467298726001844?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,10,28]],"date-time":"2026-10-28T17:21:34Z","timestamp":1793208094000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1467298726001844"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,11]]},"references-count":16,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2026,11]]}},"alternative-id":["S1467298726001844"],"URL":"https:\/\/doi.org\/10.1016\/j.vaa.2026.101370","relation":{},"ISSN":["1467-2987"],"issn-type":[{"value":"1467-2987","type":"print"}],"subject":[],"published":{"date-parts":[[2026,11]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Combining an anaesthetic conserving device with a circle breathing system to minimise isoflurane waste: an in vitro study","name":"articletitle","label":"Article Title"},{"value":"Veterinary Anaesthesia and Analgesia","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.vaa.2026.101370","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 The Author(s). Published by Elsevier Ltd on behalf of Association of Veterinary Anaesthetists and American College of Veterinary Anesthesia and Analgesia.","name":"copyright","label":"Copyright"}],"article-number":"101370"}}