{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,21]],"date-time":"2025-10-21T03:24:11Z","timestamp":1761017051149,"version":"build-2065373602"},"reference-count":50,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2014,3,1]],"date-time":"2014-03-01T00:00:00Z","timestamp":1393632000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2014,3,1]],"date-time":"2014-03-01T00:00:00Z","timestamp":1393632000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Pharmacological and Toxicological Methods"],"published-print":{"date-parts":[[2014,3]]},"DOI":"10.1016\/j.vascn.2013.11.001","type":"journal-article","created":{"date-parts":[[2013,11,20]],"date-time":"2013-11-20T23:49:28Z","timestamp":1384991368000},"page":"167-176","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":7,"title":["Effects of telemetric epicardial leads and ventricular catheters on arrhythmia incidence in cynomolgus monkeys"],"prefix":"10.1016","volume":"69","author":[{"given":"David L.","family":"Holdsworth","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kyle P.","family":"O'Donohue","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joshua D.","family":"Yoder","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Janelle E.","family":"Gesaman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jill A.","family":"Dalton","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David V.","family":"Gauvin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Larry P.","family":"Tilley","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"suffix":"Jr.","given":"Francis W.K.","family":"Smith","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Theodore J.","family":"Baird","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.vascn.2013.11.001_bb0005","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1016\/j.vascn.2009.03.006","article-title":"QA interval as an indirect measure of cardiac contractility in the conscious telemeterised rat: Model optimisation and evaluation","volume":"60","author":"Adeyemi","year":"2009","journal-title":"Journal of Pharmacological and Toxicological Methods"},{"key":"10.1016\/j.vascn.2013.11.001_bb0010","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1016\/j.smim.2007.11.004","article-title":"Foreign body reaction to biomaterials","volume":"20","author":"Anderson","year":"2008","journal-title":"Seminars in Immunology"},{"key":"10.1016\/j.vascn.2013.11.001_bb8005","doi-asserted-by":"crossref","first-page":"487","DOI":"10.1254\/jphs.QT-A4","article-title":"QT PRODACT: In vivo QT assay with a conscious monkey for assessment of the potential for drug-induced QT interval prolongation","volume":"99","author":"Ando","year":"2005","journal-title":"Journal of Pharmalogical Sciences"},{"key":"10.1016\/j.vascn.2013.11.001_bb0015","doi-asserted-by":"crossref","first-page":"148","DOI":"10.1016\/j.vascn.2013.02.006","article-title":"Influence of surgically implantable telemetry solutions on in-life and post-mortem toxicology endpoints","volume":"67","author":"Baird","year":"2013","journal-title":"Journal of Pharmacological and Toxicological Methods"},{"key":"10.1016\/j.vascn.2013.11.001_bb0020","series-title":"A comprehensive guide to toxicology in drug development","article-title":"Contemporary practices in core safety pharmacology assessments","author":"Baird","year":"2013"},{"key":"10.1016\/j.vascn.2013.11.001_bb1120","series-title":"Handbook of Toxicology, Third Edition","article-title":"\u201cSafety Pharmacology\u201d","author":"Baird","year":"2013"},{"key":"10.1016\/j.vascn.2013.11.001_bb0025","first-page":"e36","article-title":"Comparison of telemetry-derived epicardial and intravascular electrocardiogram signal characteristics in cynomolgus monkeys","volume":"68","author":"Baird","year":"2013","journal-title":"Journal of Pharmacological and Toxicological Methods"},{"key":"10.1016\/j.vascn.2013.11.001_bb0035","doi-asserted-by":"crossref","first-page":"444","DOI":"10.1093\/cvr\/20.6.444","article-title":"Evaluation of the QA interval as an index of cardiac contractility in anesthetized dogs: Responses to changes in cardiac loading and heart rate","volume":"20","author":"Cambridge","year":"1986","journal-title":"Cardiovascular Research"},{"key":"10.1016\/j.vascn.2013.11.001_bb0030","doi-asserted-by":"crossref","first-page":"220","DOI":"10.1016\/S0022-3565(24)36775-8","article-title":"Electrophysiological characterization of the prokinetic agents cisapride and mosapride in vivo and in vitro: Implications for proarrhythmic potential?","volume":"282","author":"Carlsson","year":"1997","journal-title":"Journal of Pharmacology and Experimental Therapeutics"},{"key":"10.1016\/j.vascn.2013.11.001_bb9005","doi-asserted-by":"crossref","first-page":"855","DOI":"10.1517\/14740338.2010.510131","article-title":"Cardiovascular system assessment best practices: A Safety Pharmacology Society meeting","volume":"9","author":"Cavero","year":"2010","journal-title":"Expert Opinion on Drug Safety"},{"key":"10.1016\/j.vascn.2013.11.001_bb0040","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1016\/j.vascn.2012.05.002","article-title":"Comprehensive analysis of cardiac arrhythmias in telemetered cynomolgus monkeys over a 6month period","volume":"66","author":"Chui","year":"2012","journal-title":"Journal of Pharmacological and Toxicological Methods"},{"key":"10.1016\/j.vascn.2013.11.001_bb0045","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1016\/j.vascn.2011.04.001","article-title":"J. ECG arrhythmias in non-implanted vs. telemetry-implanted dogs: Need for screening before and sufficient recovery time after implantation","volume":"64","author":"Cools","year":"2011","journal-title":"Journal of Pharmacological and Toxicological Methods"},{"key":"10.1016\/j.vascn.2013.11.001_bb0050","doi-asserted-by":"crossref","first-page":"645","DOI":"10.1016\/S0022-5223(19)40606-5","article-title":"Long-term evaluation in large dogs and sheep of a series of new fixed-rate and ventricular synchronous pacemakers","volume":"66","author":"Cummings","year":"1973","journal-title":"Journal of Thoracic and Cardiovascular Surgery"},{"key":"10.1016\/j.vascn.2013.11.001_bb0055","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1016\/j.pharmthera.2013.04.008","article-title":"The Lamberth Conventions (II): Guidelines for the study of animal and human ventricular and supraventricular arrhythmias","volume":"139","author":"Curtis","year":"2013","journal-title":"Pharmacology and Therapeutics"},{"key":"10.1016\/j.vascn.2013.11.001_bb0060","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1016\/S0002-8703(77)80174-9","article-title":"Cardiac pathology of transvenous pacemakers in dogs","volume":"93","author":"Fishbein","year":"1977","journal-title":"American Heart Journal"},{"key":"10.1016\/j.vascn.2013.11.001_bb0065","doi-asserted-by":"crossref","first-page":"439","DOI":"10.1016\/0002-8703(62)90026-1","article-title":"Arrhythmias induced during intracardiac catheterization","volume":"64","author":"Fraser","year":"1962","journal-title":"American Heart Journal"},{"key":"10.1016\/j.vascn.2013.11.001_bb0070","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1016\/j.vascn.2008.12.001","article-title":"Spontaneous cardiac arrhythmias recorded in three experimentally- and drug-na\u00efve laboratory species (canine, primate, swine) during standard pre-study screening","volume":"59","author":"Gauvin","year":"2009","journal-title":"Journal of Pharmacological and Toxicological Methods"},{"key":"10.1016\/j.vascn.2013.11.001_bb0075","doi-asserted-by":"crossref","first-page":"276","DOI":"10.1016\/j.pharmthera.2006.08.006","article-title":"Animal models of ventricular arrhythmias","volume":"113","author":"Hamlin","year":"2007","journal-title":"Pharmacology and Therapeutics"},{"key":"10.1016\/j.vascn.2013.11.001_bb0080","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1016\/j.vascn.2010.05.010","article-title":"An approach to the assessment of drug-induced changes in non-electrophysiological properties of cardiovascular function","volume":"62","author":"Hamlin","year":"2010","journal-title":"Journal of Pharmacological and Toxicological Methods"},{"key":"10.1016\/j.vascn.2013.11.001_bb0085","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1016\/j.vascn.2012.01.001","article-title":"dP\/dtmax \u2014 A measure of baroinometry","volume":"66","author":"Hamlin","year":"2012","journal-title":"Journal of Pharmacological and Toxicological Methods"},{"key":"10.1016\/j.vascn.2013.11.001_bb9015","doi-asserted-by":"crossref","first-page":"741","DOI":"10.1016\/S0008-6363(00)00310-2","article-title":"Methods of collecting and evaluating non-clinical cardiac electrophysiology data in the pharmaceutical industry: results of an international survey","volume":"49","author":"Hammond","year":"2001","journal-title":"Cardiovascular Research"},{"key":"10.1016\/j.vascn.2013.11.001_bb9020","doi-asserted-by":"crossref","first-page":"1457","DOI":"10.1038\/bjp.2008.275","article-title":"The cardiovascular and pharmacokinetic profile of dofetilide in conscious telemetered beagle dogs and cynomolgus monkeys","volume":"154","author":"Haushalter","year":"2008","journal-title":"British Journal of Pharmacology"},{"key":"10.1016\/j.vascn.2013.11.001_bb0090","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1016\/j.vascn.2010.05.017","article-title":"Left thoracotomy surgical approach for chronic instrumentation in dogs and monkeys providing high-quality electrocardiogram signals","volume":"62","author":"Henriques","year":"2010","journal-title":"Journal of Pharmacological and Toxicological Methods"},{"key":"10.1016\/j.vascn.2013.11.001_bb0100","doi-asserted-by":"crossref","first-page":"e32","DOI":"10.1016\/j.vascn.2013.01.120","article-title":"Incidence of ventricular arrhythmia in cynomolgus monkeys instrumented with intra-ventricular pressure transducers: A one year review post-implantation","volume":"68","author":"Holdsworth","year":"2013","journal-title":"Journal of Pharmacological and Toxicological Methods"},{"key":"10.1016\/j.vascn.2013.11.001_bb0105","doi-asserted-by":"crossref","first-page":"e44","DOI":"10.1016\/j.vascn.2011.03.155","article-title":"Incidence of arrhythmia in cynomolgus monkeys instrumented for telemetry with epicardial (EPI) ECG lead orientation","volume":"64","author":"Holdsworth","year":"2011","journal-title":"Journal of Pharmacological and Toxicological Methods"},{"key":"10.1016\/j.vascn.2013.11.001_bb0095","doi-asserted-by":"crossref","first-page":"e46","DOI":"10.1016\/j.vascn.2010.11.157","article-title":"Prevalence and challenges of ventricular arrhythmia associated with intra-ventricular telemetry instrumentation","volume":"62","author":"Holdsworth","year":"2010","journal-title":"Journal of Pharmacological and Toxicological Methods"},{"key":"10.1016\/j.vascn.2013.11.001_bb0110","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1016\/j.vascn.2012.07.002","article-title":"Drug-induced effects on cardiovascular function in pentobarbital anesthetized guinea-pigs: Invasive LVP measurements versus the QA interval","volume":"66","author":"Johnson","year":"2012","journal-title":"Journal of Pharmacological and Toxicological Methods"},{"key":"10.1016\/j.vascn.2013.11.001_bb0115","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1016\/j.vascn.2012.04.008","article-title":"Quickly finding a needle in a haystack: A new automated cardiac arrhythmia detection software for preclinical studies","volume":"66","author":"Koeppel","year":"2012","journal-title":"Journal of Pharmacological and Toxicological Methods"},{"key":"10.1016\/j.vascn.2013.11.001_bb0120","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1016\/j.vascn.2011.08.006","article-title":"Best practice in the conduct of key nonclinical cardiovascular safety assessments in drug development: Current recommendations from the Safety Pharmacology Society","volume":"65","author":"Leishman","year":"2011","journal-title":"Journal of Pharmacological and Toxicological Methods"},{"key":"10.1016\/j.vascn.2013.11.001_bb9030","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1016\/j.vascn.2008.07.001","article-title":"Benchmarking safety pharmacology regulatory packages and best practice","volume":"58","author":"Lindgren","year":"2008","journal-title":"Journal of Pharmacological and Toxicological Methods"},{"key":"10.1016\/j.vascn.2013.11.001_bb0125","doi-asserted-by":"crossref","first-page":"327","DOI":"10.2460\/ajvr.1993.54.02.327","article-title":"Characterization of cardiac alterations in nonsedated cynomolgus monkeys","volume":"54","author":"Macallum","year":"1993","journal-title":"American Journal of Veterinary Research"},{"key":"10.1016\/j.vascn.2013.11.001_bb0130","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1016\/j.vascn.2007.03.004","article-title":"The value added by measuring myocardial contractility \u2018in vivo\u2019 in safety pharmacological profiling of drug candidates","volume":"56","author":"Markert","year":"2007","journal-title":"Journal of Pharmacological and Toxicological Methods"},{"key":"10.1016\/j.vascn.2013.11.001_bb0135","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1016\/j.vascn.2008.12.004","article-title":"Validation of the normal, freely moving Gottingen minipig for pharmacological safety testing","volume":"60","author":"Markert","year":"2009","journal-title":"Journal of Pharmacological and Toxicological Methods"},{"key":"10.1016\/j.vascn.2013.11.001_bb0140","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1016\/j.vascn.2010.05.018","article-title":"Evaluation of blood pressure measurement using a miniature blood pressure transmitter with jacketed external telemetry in cynomolgus monkeys","volume":"62","author":"McMahon","year":"2010","journal-title":"Journal of Pharmacological and Toxicological Methods"},{"key":"10.1016\/j.vascn.2013.11.001_bb0145","doi-asserted-by":"crossref","DOI":"10.1016\/j.vascn.2013.04.006","article-title":"Intravenous solid tip ECG lead placement in telemetry implanted dogs: Part 2: High quality telemetry signals yield high sensitivity to drug-induced changes","author":"Mitchell","year":"2013","journal-title":"Journal of Pharmacological and Toxicological Methods"},{"key":"10.1016\/j.vascn.2013.11.001_bb9000","first-page":"184","article-title":"A modified left thoracotomy approach for enhancing ECG P-wave detection in the cynomolgus monkey","volume":"66","author":"Moddrelle","year":"2012","journal-title":"Journal of Pharmacological and Toxicological Methods"},{"key":"10.1016\/j.vascn.2013.11.001_bb0150","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1016\/j.vascn.2012.05.008","article-title":"Optimising conditions for studying the acute effects of drugs on indices of cardiac contractility and on haemodynamics in anaesthetized guinea pigs","volume":"66","author":"Mooney","year":"2012","journal-title":"Journal of Pharmacological and Toxicological Methods"},{"key":"10.1016\/j.vascn.2013.11.001_bb0155","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1016\/j.vascn.2009.05.008","article-title":"Assessment of the pharmacological effects of inotropic drugs on left ventricular pressure and contractility: An evaluation of the QA interval as an indirect indicator of cardiac inotropism","volume":"60","author":"Norton","year":"2009","journal-title":"Journal of Pharmacological and Toxicological Methods"},{"key":"10.1016\/j.vascn.2013.11.001_bb0160","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1016\/j.vascn.2012.08.107","article-title":"A stepwise approach to quantitative arrhythmia assessment: A multi-species and multi-drug validation","volume":"66","author":"O'Donohue","year":"2012","journal-title":"Journal of Pharmacological and Toxicological Methods"},{"key":"10.1016\/j.vascn.2013.11.001_bb0165","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1016\/j.vascn.2012.05.004","article-title":"Methodological innovations expand the safety pharmacology horizon","volume":"66","author":"Pugsley","year":"2012","journal-title":"Journal of Pharmacological and Toxicological Methods"},{"key":"10.1016\/j.vascn.2013.11.001_bb0170","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1016\/j.vascn.2008.10.002","article-title":"Long-term assessment of blood pressure transducer drift in rhesus monkeys chronically instrumented with telemetry implants","volume":"59","author":"Regan","year":"2009","journal-title":"Journal of Pharmacological and Toxicological Methods"},{"key":"10.1016\/j.vascn.2013.11.001_bb0180","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1016\/j.vascn.2012.05.009","article-title":"Left ventricular pressure, contractility and dP\/dtmax in nonclinical drug safety assessment studies","volume":"66","author":"Sarazan","year":"2012","journal-title":"Journal of Pharmacological and Toxicological Methods"},{"key":"10.1016\/j.vascn.2013.11.001_bb0175","doi-asserted-by":"crossref","first-page":"272","DOI":"10.1177\/1091581811398963","article-title":"Cardiovascular function in nonclinical drug safety assessment: Current issues and opportunities","volume":"30","author":"Sarazan","year":"2011","journal-title":"International Journal of Toxicology"},{"key":"10.1016\/j.vascn.2013.11.001_bb9050","doi-asserted-by":"crossref","first-page":"1528","DOI":"10.1038\/bjp.2008.240","article-title":"Sensitive and reliable proarrhythmia in vivo animal models for predicting drug-induced torsades de pointes in patients with remodeled hearts","volume":"154","author":"Sugiyama","year":"2008","journal-title":"British Journal of Pharmacology"},{"key":"10.1016\/j.vascn.2013.11.001_bb0195","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1016\/S0014-2999(01)00740-3","article-title":"Cardiovascular action of a cardioselective Ca2+ channel blocker, AH-1058 in conscious dogs assessed by telemetry","volume":"413","author":"Takahara","year":"2001","journal-title":"European Journal of Pharmacology"},{"year":"1992","series-title":"Essentials of canine and feline electrocardiography: Interpretation and treatment","author":"Tilley","key":"10.1016\/j.vascn.2013.11.001_bb0185"},{"year":"2001","series-title":"Manual of canine and feline cardiology","author":"Tilley","key":"10.1016\/j.vascn.2013.11.001_bb0190"},{"key":"10.1016\/j.vascn.2013.11.001_bb0200","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1016\/S1056-8719(00)00126-X","article-title":"Direct and indirect methods used to study arterial blood pressure","volume":"44","author":"Van Vliet","year":"2000","journal-title":"Journal of Pharmacological and Toxicological Methods"},{"issue":"3","key":"10.1016\/j.vascn.2013.11.001_bb0205","doi-asserted-by":"crossref","first-page":"864","DOI":"10.1161\/01.CIR.91.3.864","article-title":"Reproducible induction of early afterdepolarizations and torsade de pointes arrhythmias by d-sotalol and pacing in dogs with chronic atrioventricular block","volume":"91","author":"Vos","year":"1995","journal-title":"Circulation"},{"key":"10.1016\/j.vascn.2013.11.001_bb0210","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1016\/j.vascn.2009.05.009","article-title":"Evaluation of electrocardiograms recorded in cynomolgus monkeys with short- and long-term intracardiac lead implantations","volume":"60","author":"Yao","year":"2009","journal-title":"Journal of Pharmacological and Toxicological Methods"}],"container-title":["Journal of Pharmacological and Toxicological Methods"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1056871913003201?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1056871913003201?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,20]],"date-time":"2025-10-20T23:58:13Z","timestamp":1761004693000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1056871913003201"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,3]]},"references-count":50,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2014,3]]}},"alternative-id":["S1056871913003201"],"URL":"https:\/\/doi.org\/10.1016\/j.vascn.2013.11.001","relation":{},"ISSN":["1056-8719"],"issn-type":[{"type":"print","value":"1056-8719"}],"subject":[],"published":{"date-parts":[[2014,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Effects of telemetric epicardial leads and ventricular catheters on arrhythmia incidence in cynomolgus monkeys","name":"articletitle","label":"Article Title"},{"value":"Journal of Pharmacological and Toxicological Methods","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.vascn.2013.11.001","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2013 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}