{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,21]],"date-time":"2026-09-21T07:45:00Z","timestamp":1789976700926,"version":"4.0.1"},"reference-count":65,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2018,5,1]],"date-time":"2018-05-01T00:00:00Z","timestamp":1525132800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2018,5,1]],"date-time":"2018-05-01T00:00:00Z","timestamp":1525132800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"name":"Latvian National research program SOPHIS","award":["Nr.10-4\/VPP-4\/11"],"award-info":[{"award-number":["Nr.10-4\/VPP-4\/11"]}]},{"DOI":"10.13039\/501100007060","name":"Riga Technical University","doi-asserted-by":"publisher","award":["Nr.04000-1.1\/17"],"award-info":[{"award-number":["Nr.04000-1.1\/17"]}],"id":[{"id":"10.13039\/501100007060","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Water Research"],"published-print":{"date-parts":[[2018,5]]},"DOI":"10.1016\/j.watres.2018.02.006","type":"journal-article","created":{"date-parts":[[2018,2,5]],"date-time":"2018-02-05T23:27:15Z","timestamp":1517873235000},"page":"11-21","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":96,"special_numbering":"C","title":["Identifying the underlying causes of biological instability in a full-scale drinking water supply system"],"prefix":"10.1016","volume":"135","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4689-2545","authenticated-orcid":false,"given":"Alina","family":"Nescerecka","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Talis","family":"Juhna","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Frederik","family":"Hammes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.watres.2018.02.006_bib1","series-title":"Effects of Water Age on Distribution System Water Quality","author":"AWWA","year":"2002"},{"key":"10.1016\/j.watres.2018.02.006_bib2","doi-asserted-by":"crossref","first-page":"4010","DOI":"10.1016\/j.watres.2008.07.017","article-title":"Rapid, cultivation-independent assessment of microbial viability in drinking water","volume":"42","author":"Berney","year":"2008","journal-title":"Water Res."},{"key":"10.1016\/j.watres.2018.02.006_bib3","doi-asserted-by":"crossref","DOI":"10.1038\/srep38462","article-title":"Online flow cytometry reveals microbial dynamics influenced by concurrent natural and operational events in groundwater used for drinking water treatment","volume":"6","author":"Besmer","year":"2016","journal-title":"Sci. Rep."},{"key":"10.1016\/j.watres.2018.02.006_bib4","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1016\/j.watres.2016.10.041","article-title":"Short-term microbial dynamics in a drinking water plant treating groundwater with occasional high microbial loads","volume":"107","author":"Besmer","year":"2016","journal-title":"Water Res."},{"key":"10.1016\/j.watres.2018.02.006_bib5","doi-asserted-by":"crossref","DOI":"10.3389\/fmicb.2014.00265","article-title":"The feasibility of automated online flow cytometry for in-situ monitoring of microbial dynamics in aquatic ecosystems","volume":"5","author":"Besmer","year":"2014","journal-title":"Front. Microbiol."},{"key":"10.1016\/j.watres.2018.02.006_bib6","first-page":"355","article-title":"Involvement of humic substances in regrowth","volume":"92","author":"Camper","year":"2004","journal-title":"Int. J. Food Microbiol. HPC Bact. Drink. Water Pub. Health Implications"},{"key":"10.1016\/j.watres.2018.02.006_bib7","doi-asserted-by":"crossref","first-page":"318","DOI":"10.1016\/j.desal.2005.12.070","article-title":"Effectiveness of AOC removal by advanced water treatment systems: a case study","volume":"202","author":"Chien","year":"2007","journal-title":"Desalination"},{"key":"10.1016\/j.watres.2018.02.006_bib8","doi-asserted-by":"crossref","first-page":"4155","DOI":"10.1128\/AEM.00109-16","article-title":"Dynamics of biofilm regrowth in drinking water distribution systems","volume":"82","author":"Douterelo","year":"2016","journal-title":"Appl. Environ. Microbiol."},{"key":"10.1016\/j.watres.2018.02.006_bib9","doi-asserted-by":"crossref","first-page":"180","DOI":"10.1016\/j.watres.2015.02.015","article-title":"Dynamics of bacterial communities before and after distribution in a full-scale drinking water network","volume":"74","author":"El-Chakhtoura","year":"2015","journal-title":"Water Res."},{"key":"10.1016\/j.watres.2018.02.006_bib10","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1002\/j.1551-8833.2006.tb07824.x","article-title":"Effects of media, backwash, and temperature on full-scale biological filtration","volume":"98","author":"Emelko","year":"2006","journal-title":"J.\u00a0(Am. Water Works Assoc.)"},{"key":"10.1016\/j.watres.2018.02.006_bib11","doi-asserted-by":"crossref","first-page":"623","DOI":"10.1038\/nrmicro2415","article-title":"The biofilm matrix","volume":"8","author":"Flemming","year":"2010","journal-title":"Nat. Rev. Microbiol."},{"key":"10.1016\/j.watres.2018.02.006_bib12","doi-asserted-by":"crossref","first-page":"3817","DOI":"10.1016\/S0043-1354(01)00104-X","article-title":"Comparative measurements of microbial activity in drinking water biofilters","volume":"35","author":"Fonseca","year":"2001","journal-title":"Water Res."},{"key":"10.1016\/j.watres.2018.02.006_bib13","doi-asserted-by":"crossref","first-page":"1075","DOI":"10.1016\/j.watres.2008.11.030","article-title":"Modeling of heterotrophic bacteria counts in a water distribution system","volume":"43","author":"Francisque","year":"2009","journal-title":"Water Res."},{"key":"10.1016\/j.watres.2018.02.006_bib14","doi-asserted-by":"crossref","first-page":"224","DOI":"10.1016\/j.watres.2014.07.029","article-title":"Assessing microbiological water quality in drinking water distribution systems with disinfectant residual using flow cytometry","volume":"65","author":"Gillespie","year":"2014","journal-title":"Water Res."},{"issue":"31","key":"10.1016\/j.watres.2018.02.006_bib15","article-title":"Assessing biological stability of drinking water without disinfectant residuals in a full-scale water supply system","volume":"59","author":"Hammes","year":"2010","journal-title":"J.\u00a0Water Supply Res. Technol. - Aqua"},{"key":"10.1016\/j.watres.2018.02.006_bib16","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1016\/j.watres.2007.07.009","article-title":"Flow-cytometric total bacterial cell counts as a descriptive microbiological parameter for drinking water treatment processes","volume":"42","author":"Hammes","year":"2008","journal-title":"Water Res."},{"key":"10.1016\/j.watres.2018.02.006_bib17","doi-asserted-by":"crossref","first-page":"772","DOI":"10.1128\/br.30.4.772-794.1966","article-title":"Inorganic polyphosphates in biology: structure, metabolism, and function","volume":"30","author":"Harold","year":"1966","journal-title":"Bacteriol. Rev."},{"key":"10.1016\/j.watres.2018.02.006_bib18","doi-asserted-by":"crossref","first-page":"585","DOI":"10.1016\/S0167-7012(03)00201-X","article-title":"Enumeration of water-borne bacteria using viability assays and flow cytometry: a comparison to culture-based techniques","volume":"55","author":"Hoefel","year":"2003","journal-title":"J.\u00a0Microbiol. Meth."},{"key":"10.1016\/j.watres.2018.02.006_bib19","doi-asserted-by":"crossref","first-page":"607","DOI":"10.1002\/bit.10503","article-title":"Simulation of growth and detachment in biofilm systems under defined hydrodynamic conditions","volume":"81","author":"Horn","year":"2003","journal-title":"Biotechnol. Bioeng."},{"key":"10.1016\/j.watres.2018.02.006_bib20","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1016\/j.watres.2014.08.006","article-title":"Effect of drinking water treatment process parameters on biological removal of manganese from surface water","volume":"66","author":"Hoyland","year":"2014","journal-title":"Water Res."},{"key":"10.1016\/j.watres.2018.02.006_bib21","series-title":"Microbes in Pipes: the Microbiology of the Water Distribution System","author":"Ingerson-Mahar","year":"2012"},{"key":"10.1016\/j.watres.2018.02.006_bib22","doi-asserted-by":"crossref","first-page":"575","DOI":"10.1016\/S0043-1354(99)00179-7","article-title":"In situ probing reveals Aquabacterium commune as a widespread and highly abundant bacterial species in drinking water biofilms","volume":"34","author":"Kalmbach","year":"2000","journal-title":"Water Res."},{"key":"10.1016\/j.watres.2018.02.006_bib23","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0098542","article-title":"Temporal variations in the abundance and composition of biofilm communities colonizing drinking water distribution pipes","volume":"9","author":"Kelly","year":"2014","journal-title":"PLoS One"},{"key":"10.1016\/j.watres.2018.02.006_bib24","doi-asserted-by":"crossref","first-page":"542","DOI":"10.1021\/acs.est.5b03973","article-title":"Intermittent water supply: prevalence, practice, and microbial water quality","volume":"50","author":"Kumpel","year":"2016","journal-title":"Environ. Sci. Technol."},{"key":"10.1016\/j.watres.2018.02.006_bib25","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1016\/j.watres.2014.05.035","article-title":"Abundance and composition of indigenous bacterial communities in a multi-step biofiltration-based drinking water treatment plant","volume":"62","author":"Lautenschlager","year":"2014","journal-title":"Water Res."},{"key":"10.1016\/j.watres.2018.02.006_bib26","doi-asserted-by":"crossref","first-page":"3015","DOI":"10.1016\/j.watres.2013.03.002","article-title":"A\u00a0microbiology-based multi-parametric approach towards assessing biological stability in drinking water distribution networks","volume":"47","author":"Lautenschlager","year":"2013","journal-title":"Water Res."},{"key":"10.1016\/j.watres.2018.02.006_bib27","doi-asserted-by":"crossref","first-page":"857","DOI":"10.1128\/aem.57.3.857-862.1991","article-title":"Bacterial nutrients in drinking water","volume":"57","author":"LeChevallier","year":"1991","journal-title":"Appl. Environ. Microbiol."},{"key":"10.1016\/j.watres.2018.02.006_bib28","doi-asserted-by":"crossref","first-page":"2201","DOI":"10.1128\/aem.62.7.2201-2211.1996","article-title":"Full-scale studies of factors related to coliform regrowth in drinking water","volume":"62","author":"LeChevallier","year":"1996","journal-title":"Appl. Environ. Microbiol."},{"key":"10.1016\/j.watres.2018.02.006_bib29","doi-asserted-by":"crossref","first-page":"2151","DOI":"10.1016\/j.watres.2006.04.010","article-title":"The effects of changing water flow velocity on the formation of biofilms and water quality in pilot distribution system consisting of copper or polyethylene pipes","volume":"40","author":"Lehtola","year":"2006","journal-title":"Water Res."},{"key":"10.1016\/j.watres.2018.02.006_bib30","doi-asserted-by":"crossref","first-page":"2032","DOI":"10.1128\/AEM.65.5.2032-2034.1999","article-title":"A\u00a0new sensitive bioassay for determination of microbially available phosphorus in water","volume":"65","author":"Lehtola","year":"1999","journal-title":"Appl. Environ. Microbiol."},{"key":"10.1016\/j.watres.2018.02.006_bib31","article-title":"Flow cytometry total cell counts: a field study assessing microbiological water quality and growth in unchlorinated drinking water distribution systems","volume":"2013","author":"Liu","year":"2013","journal-title":"BioMed Res. Int."},{"key":"10.1016\/j.watres.2018.02.006_bib32","doi-asserted-by":"crossref","first-page":"923","DOI":"10.1002\/ece3.1955","article-title":"Bacterial characterization of Beijing drinking water by flow cytometry and MiSeq sequencing of the 16S rRNA gene","volume":"6","author":"Liu","year":"2016","journal-title":"Ecol. Evol."},{"key":"10.1016\/j.watres.2018.02.006_bib33","article-title":"Effects of assimilable organic carbon and free chlorine on bacterial growth in drinking water","volume":"10","author":"Liu","year":"2015","journal-title":"PLoS One"},{"key":"10.1016\/j.watres.2018.02.006_bib34","doi-asserted-by":"crossref","first-page":"1858","DOI":"10.1016\/0043-1354(96)00052-8","article-title":"Thiosulfate interference in the biodegradable dissolved organic carbon assay","volume":"30","author":"Maclean","year":"1996","journal-title":"Water Res."},{"key":"10.1016\/j.watres.2018.02.006_bib35","doi-asserted-by":"crossref","first-page":"3242","DOI":"10.1128\/aem.63.8.3242-3245.1997","article-title":"Phosphorus and bacterial growth in drinking water","volume":"63","author":"Miettinen","year":"1997","journal-title":"Appl. Environ. Microbiol."},{"key":"10.1016\/j.watres.2018.02.006_bib36","doi-asserted-by":"crossref","first-page":"654","DOI":"10.1038\/381654b0","article-title":"Contamination of drinking water","volume":"381","author":"Miettinen","year":"1996","journal-title":"Nature"},{"key":"10.1016\/j.watres.2018.02.006_bib37","doi-asserted-by":"crossref","first-page":"2377","DOI":"10.1021\/es9900757","article-title":"Impact of temperature on drinking water biofilter performance and microbial community structure","volume":"33","author":"Moll","year":"1999","journal-title":"Environ. Sci. Technol."},{"key":"10.1016\/j.watres.2018.02.006_bib38","doi-asserted-by":"crossref","first-page":"2883","DOI":"10.1016\/j.watres.2005.05.024","article-title":"Implications of nutrient release from iron metal for microbial regrowth in water distribution systems","volume":"39","author":"Morton","year":"2005","journal-title":"Water Res."},{"key":"10.1016\/j.watres.2018.02.006_bib39","doi-asserted-by":"crossref","first-page":"490","DOI":"10.1016\/j.watres.2016.05.087","article-title":"Behavior and stability of adenosine triphosphate (ATP) during chlorine disinfection","volume":"101","author":"Nescerecka","year":"2016","journal-title":"Water Res."},{"key":"10.1016\/j.watres.2018.02.006_bib40","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0096354","article-title":"Biological instability in a chlorinated drinking water distribution network","volume":"9","author":"Nescerecka","year":"2014","journal-title":"PLoS One"},{"key":"10.1016\/j.watres.2018.02.006_bib41","doi-asserted-by":"crossref","first-page":"675","DOI":"10.1016\/S0043-1354(00)00303-1","article-title":"Bacterial dynamics in the drinking water distribution system of Brussels","volume":"35","author":"Niquette","year":"2001","journal-title":"Water Res."},{"key":"10.1016\/j.watres.2018.02.006_bib42","doi-asserted-by":"crossref","DOI":"10.1128\/mBio.01135-14","article-title":"Spatial-temporal survey and occupancy-abundance modeling to predict bacterial community dynamics in the drinking water microbiome","volume":"5","author":"Pinto","year":"2014","journal-title":"mBio"},{"key":"10.1016\/j.watres.2018.02.006_bib43","doi-asserted-by":"crossref","first-page":"8851","DOI":"10.1021\/es302042t","article-title":"Bacterial community structure in the drinking water microbiome Is governed by filtration processes","volume":"46","author":"Pinto","year":"2012","journal-title":"Environ. Sci. Technol."},{"key":"10.1016\/j.watres.2018.02.006_bib44","doi-asserted-by":"crossref","first-page":"2259","DOI":"10.1016\/j.watres.2005.04.015","article-title":"Investigation of assimilable organic carbon (AOC) in flemish drinking water","volume":"39","author":"Polanska","year":"2005","journal-title":"Water Res."},{"issue":"4","key":"10.1016\/j.watres.2018.02.006_bib45","doi-asserted-by":"crossref","first-page":"865","DOI":"10.2166\/ws.2016.001","article-title":"A\u00a0systematic approach for the assessment of bacterial growth-controlling factors linked to biological stability of drinking water in distribution systems","volume":"16","author":"Prest","year":"2016","journal-title":"Water Sci. Technol. Water Supply"},{"key":"10.1016\/j.watres.2018.02.006_bib46","doi-asserted-by":"crossref","first-page":"7131","DOI":"10.1016\/j.watres.2013.07.051","article-title":"Monitoring microbiological changes in drinking water systems using a fast and reproducible flow cytometric method","volume":"47","author":"Prest","year":"2013","journal-title":"Water Res."},{"key":"10.1016\/j.watres.2018.02.006_bib47","doi-asserted-by":"crossref","DOI":"10.3389\/fmicb.2016.00045","article-title":"Biological stability of drinking water: controlling factors, methods, and challenges","volume":"7","author":"Prest","year":"2016","journal-title":"Front. Microbiol."},{"key":"10.1016\/j.watres.2018.02.006_bib48","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0164445","article-title":"Long-term bacterial dynamics in a full-scale drinking water distribution system","volume":"11","author":"Prest","year":"2016","journal-title":"PLoS One"},{"key":"10.1016\/j.watres.2018.02.006_bib49","doi-asserted-by":"crossref","first-page":"1490","DOI":"10.1016\/j.watres.2010.11.016","article-title":"Kinetics of membrane damage to high (HNA) and low (LNA) nucleic acid bacterial clusters in drinking water by ozone, chlorine, chlorine dioxide, monochloramine, ferrate(VI), and permanganate","volume":"45","author":"Ramseier","year":"2011","journal-title":"Water Res."},{"key":"10.1016\/j.watres.2018.02.006_bib50","doi-asserted-by":"crossref","first-page":"106","DOI":"10.1002\/j.1551-8833.1984.tb05427.x","article-title":"Achieving biologically stable drinking water","volume":"76","author":"Rittmann","year":"1984","journal-title":"J.\u00a0Am. Water Works Assoc."},{"key":"10.1016\/j.watres.2018.02.006_bib51","doi-asserted-by":"crossref","first-page":"211","DOI":"10.2166\/wst.2007.261","article-title":"Evaluating the potential of biofilm control in water supply systems by removal of phosphorus from drinking water","volume":"55","author":"Rubulis","year":"2007","journal-title":"Water Sci. Technol."},{"key":"10.1016\/j.watres.2018.02.006_bib52","doi-asserted-by":"crossref","first-page":"37","DOI":"10.2166\/wst.1997.0295","article-title":"Role of inorganic phosphorus in controlling regrowth in water distribution system","volume":"35","author":"Sathasivan","year":"1997","journal-title":"Water Sci. Technol."},{"key":"10.1016\/j.watres.2018.02.006_bib53","doi-asserted-by":"crossref","first-page":"2732","DOI":"10.1128\/aem.55.10.2732-2734.1989","article-title":"Simple method for determination of biodegradable dissolved organic carbon in water","volume":"55","author":"Servais","year":"1989","journal-title":"Appl. Environ. Microbiol."},{"key":"10.1016\/j.watres.2018.02.006_bib54","first-page":"163","article-title":"A\u00a0pilot study of biological GAC filtration in drinking-water treatment. Journal of water supply: research and technology","volume":"41","author":"Servais","year":"1992","journal-title":"Aqua"},{"key":"10.1016\/j.watres.2018.02.006_bib55","doi-asserted-by":"crossref","first-page":"267","DOI":"10.1080\/08927010500398633","article-title":"Impact of flow velocity on the dynamic behaviour of biofilm bacteria","volume":"21","author":"Tsai","year":"2005","journal-title":"Biofouling"},{"key":"10.1016\/j.watres.2018.02.006_bib56","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1023\/A:1005288720291","article-title":"Biological Stability: a multidimensional quality aspect of treated water","volume":"123","author":"van der Kooij","year":"2000","journal-title":"Water, Air, Soil Pollut."},{"key":"10.1016\/j.watres.2018.02.006_bib57","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1002\/j.1551-8833.1992.tb07305.x","article-title":"Assimilable organic carbon as an indicator of bacterial regrowth","volume":"84","author":"van der Kooij","year":"1992","journal-title":"J.\u00a0Am. Water Works Assoc."},{"key":"10.1016\/j.watres.2018.02.006_bib58","doi-asserted-by":"crossref","first-page":"540","DOI":"10.1002\/j.1551-8833.1982.tb05000.x","article-title":"Determining the concentration of easily assimilable organic carbon in drinking water","volume":"74","author":"van der Kooij","year":"1982","journal-title":"J.\u00a0(Am. Water Works Assoc.)"},{"key":"10.1016\/j.watres.2018.02.006_bib59","doi-asserted-by":"crossref","first-page":"4860","DOI":"10.1016\/j.watres.2010.07.016","article-title":"Effect of water composition, distance and season on the adenosine triphosphate concentration in unchlorinated drinking water in The Netherlands","volume":"44","author":"van der Wielen","year":"2010","journal-title":"Water Res."},{"key":"10.1016\/j.watres.2018.02.006_bib60","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1016\/j.watres.2017.01.065","article-title":"Flow cytometric bacterial cell counts challenge conventional heterotrophic plate counts for routine microbiological drinking water monitoring","volume":"113","author":"Van Nevel","year":"2017","journal-title":"Water Res."},{"key":"10.1016\/j.watres.2018.02.006_bib61","doi-asserted-by":"crossref","first-page":"4665","DOI":"10.1016\/j.watres.2012.06.010","article-title":"Flow cytometry and adenosine tri-phosphate analysis: alternative possibilities to evaluate major bacteriological changes in drinking water treatment and distribution systems","volume":"46","author":"Vital","year":"2012","journal-title":"Water Res."},{"key":"10.1016\/j.watres.2018.02.006_bib62","doi-asserted-by":"crossref","first-page":"1967","DOI":"10.1016\/S0043-1354(99)00342-5","article-title":"Practical evaluation of iron corrosion control in a drinking water distribution system","volume":"34","author":"Volk","year":"2000","journal-title":"Water Res."},{"key":"10.1016\/j.watres.2018.02.006_bib63","doi-asserted-by":"crossref","first-page":"4957","DOI":"10.1128\/AEM.65.11.4957-4966.1999","article-title":"Impacts of the reduction of nutrient levels on bacterial water quality in distribution systems","volume":"65","author":"Volk","year":"1999","journal-title":"Appl. Environ. Microbiol."},{"key":"10.1016\/j.watres.2018.02.006_bib64","doi-asserted-by":"crossref","first-page":"1469","DOI":"10.1016\/S0043-1354(02)00458-X","article-title":"Ozonation of drinking water: Part II. Disinfection and by-product formation in presence of bromide, iodide or chlorine","volume":"37","author":"von Gunten","year":"2003","journal-title":"Water Res."},{"key":"10.1016\/j.watres.2018.02.006_bib65","series-title":"WHO | Guidelines for Drinking-water Quality - Volume 1: Recommendations. WHO","author":"WHO","year":"2008"}],"container-title":["Water Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0043135418301052?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0043135418301052?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,23]],"date-time":"2025-09-23T01:46:08Z","timestamp":1758591968000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0043135418301052"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,5]]},"references-count":65,"alternative-id":["S0043135418301052"],"URL":"https:\/\/doi.org\/10.1016\/j.watres.2018.02.006","relation":{},"ISSN":["0043-1354"],"issn-type":[{"value":"0043-1354","type":"print"}],"subject":[],"published":{"date-parts":[[2018,5]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Identifying the underlying causes of biological instability in a full-scale drinking water supply system","name":"articletitle","label":"Article Title"},{"value":"Water Research","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.watres.2018.02.006","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2018 Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}