{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T05:54:48Z","timestamp":1787810088340,"version":"build-2784847793"},"reference-count":33,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2019,2,1]],"date-time":"2019-02-01T00:00:00Z","timestamp":1548979200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2019,2,1]],"date-time":"2019-02-01T00:00:00Z","timestamp":1548979200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Water Research"],"published-print":{"date-parts":[[2019,2]]},"DOI":"10.1016\/j.watres.2018.11.032","type":"journal-article","created":{"date-parts":[[2018,11,16]],"date-time":"2018-11-16T02:36:36Z","timestamp":1542335796000},"page":"460-466","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":45,"special_numbering":"C","title":["Role of hot water temperature and water system use on Legionella control in a tertiary hospital: An 8-year longitudinal study"],"prefix":"10.1016","volume":"149","author":[{"given":"Laura","family":"Gavald\u00e0","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marian","family":"Garcia-Nu\u00f1ez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sara","family":"Quero","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carmen","family":"Gutierrez-Milla","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Miquel","family":"Sabri\u00e0","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.watres.2018.11.032_bib1","series-title":"Norma Espa\u00f1ola UNE 100030:2017. Prevenci\u00f3n y control de la proliferaci\u00f3n y diseminaci\u00f3n de Legionella en instalaciones","author":"Asociaci\u00f3n Espa\u00f1ola de Normalizaci\u00f3n","year":"2017"},{"key":"10.1016\/j.watres.2018.11.032_bib2","doi-asserted-by":"crossref","first-page":"244","DOI":"10.1016\/j.watres.2015.01.006","article-title":"Temperature diagnostic to identify high risk areas and optimize Legionella pneumophila surveillance in hot water distribution systems","volume":"71","author":"B\u00e9dard","year":"2015","journal-title":"Water Res."},{"issue":"1","key":"10.1016\/j.watres.2018.11.032_bib3","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1016\/j.jhin.2004.10.016","article-title":"Water disinfection with ozone, copper and silver ions, and temperature increase to control Legionella: seven years of experience in a university teaching hospital","volume":"60","author":"Blanc","year":"2005","journal-title":"J.\u00a0Hosp. Infect."},{"issue":"9","key":"10.1016\/j.watres.2018.11.032_bib4","doi-asserted-by":"crossref","first-page":"602","DOI":"10.1086\/501812","article-title":"Long-term control of Legionella species in potable water after a nosocomial legionellosis outbreak in an intensive care unit","volume":"21","author":"Borau","year":"2000","journal-title":"Infect. Control Hosp. Epidemiol."},{"issue":"3","key":"10.1016\/j.watres.2018.11.032_bib5","doi-asserted-by":"crossref","first-page":"457","DOI":"10.3201\/eid1003.020707","article-title":"Legionella infection risk from domestic hot water","volume":"10","author":"Borella","year":"2004","journal-title":"Emerg. Infect. Dis."},{"issue":"10","key":"10.1016\/j.watres.2018.11.032_bib6","doi-asserted-by":"crossref","first-page":"617","DOI":"10.1089\/ees.2012.0514","article-title":"Role of hot water system design on factors influential to pathogen regrowth: temperature, chlorine residual, hydrogen evolution, and sediment","volume":"30","author":"Brazeau","year":"2013","journal-title":"Environ. Eng. Sci."},{"issue":"2","key":"10.1016\/j.watres.2018.11.032_bib7","doi-asserted-by":"crossref","first-page":"217","DOI":"10.1111\/j.1472-765X.2011.03094.x","article-title":"Differential growth of Legionella pneumophila strains within a range of amoebae at various temperatures associated with in-premise plumbing","volume":"53","author":"Buse","year":"2011","journal-title":"Lett. Appl. Microbiol."},{"issue":"8","key":"10.1016\/j.watres.2018.11.032_bib8","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0134726","article-title":"Effect of common drinking water disinfectants, chlorine and heat, on free Legionella and amoebae-associated Legionella","volume":"10","author":"Cervero-Arag\u00f3","year":"2015","journal-title":"PloS One"},{"issue":"5","key":"10.1016\/j.watres.2018.11.032_bib9","doi-asserted-by":"crossref","first-page":"984","DOI":"10.1128\/aem.48.5.984-987.1984","article-title":"Role of stagnation and obstruction of water flow in isolation of Legionella pneumophila from hospital plumbing","volume":"48","author":"Ciesielski","year":"1984","journal-title":"Appl. Environ. Microbiol."},{"key":"10.1016\/j.watres.2018.11.032_bib10","unstructured":"Circulaire interministerielle N\u00ba DGS\/DSC\/DGUHC\/DGE\/DPPR\/126 du 3 avril 2007 relative \u00e0 la mise en \u0153uvre de l'arr\u00eat\u00e9 du 30 novembre 2005 modifiant l'arr\u00eat\u00e9 du 23 juin 1978 relatif aux installations fixes destin\u00e9es au chauffage et \u00e0 l'alimentation en eau chaude sanitaire des b\u00e2timents d'habitation, des locaux de travail ou des locaux recevant du public."},{"issue":"2","key":"10.1016\/j.watres.2018.11.032_bib11","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1086\/674863","article-title":"The impact of aerators on water contamination by emerging gram-negative opportunists in at-risk hospital departments","volume":"35","author":"Cristina","year":"2014","journal-title":"Infect. Control Hosp. Epidemiol."},{"issue":"3","key":"10.1016\/j.watres.2018.11.032_bib12","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1053\/jhin.2002.1185","article-title":"Control of nosocomial Legionnaires' disease by keeping the circulating hot water temperature above 55 C: experience from a 10-year surveillance programme in a district general hospital","volume":"50","author":"Darelid","year":"2002","journal-title":"J.\u00a0Hosp. Infect."},{"issue":"2","key":"10.1016\/j.watres.2018.11.032_bib13","doi-asserted-by":"crossref","first-page":"349","DOI":"10.1111\/j.1365-2672.1984.tb01359.x","article-title":"A\u00a0note on the temperature tolerance of Legionella","volume":"56","author":"Dennis","year":"1984","journal-title":"J.\u00a0Appl. Bacteriol."},{"key":"10.1016\/j.watres.2018.11.032_bib14","series-title":"Technical Rule. W551 Code of Practice. Drinking Water Heating and Drinking Water Piping Systems; Technical Measures to Reduce Legionella Growth; Design, Construction, Operation and Rehabilitation of Drinking Water Installations","author":"DVGW German Technical and Scientific Association for Gas and Water","year":"2004"},{"key":"10.1016\/j.watres.2018.11.032_bib15","series-title":"European Technical Guidelines for the Prevention, Control, and Investigation of Infections Caused by Legionella Species","author":"ECDC","year":"2017"},{"issue":"3","key":"10.1016\/j.watres.2018.11.032_bib16","doi-asserted-by":"crossref","first-page":"1073","DOI":"10.1111\/j.1365-2672.2009.04541.x","article-title":"Development of a pilot-scale 1 for Legionella elimination in biofilm in hot water network: heat shock treatment evaluation","volume":"108","author":"Farhat","year":"2010","journal-title":"J.\u00a0Appl. Microbiol."},{"issue":"2","key":"10.1016\/j.watres.2018.11.032_bib17","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1053\/jhin.2001.1060","article-title":"Non-touch fittings in hospitals: a possible source of Pseudomonas aeruginosa and Legionella spp","volume":"49","author":"Halabi","year":"2001","journal-title":"J.\u00a0Hosp. Infect."},{"key":"10.1016\/j.watres.2018.11.032_bib18","series-title":"Legionnaire's Disease: Technical Guidance Part 2. The Control of Legionella Bacteria in Water Systems. Interim Guidance. Approved Code of Practice and Guidance of Regulations. L8","author":"Health and Safety Executive","year":"2013"},{"key":"10.1016\/j.watres.2018.11.032_bib19","series-title":"National Guidelines for the Control of Legionellosis in Ireland. Report of Legionnaires' Disease Sucommittee of Scientific Advisory Committee","author":"Health Protection Surveillance Centre","year":"2009"},{"issue":"1","key":"10.1016\/j.watres.2018.11.032_bib20","doi-asserted-by":"crossref","first-page":"124","DOI":"10.1186\/1471-2334-10-124","article-title":"Clinical features and predictors of mortality in admitted patients with community-and hospital-acquired legionellosis: a Danish historical cohort study","volume":"10","author":"Jespersen","year":"2010","journal-title":"BMC Infect. Dis."},{"issue":"5","key":"10.1016\/j.watres.2018.11.032_bib21","doi-asserted-by":"crossref","first-page":"546","DOI":"10.1034\/j.1600-0463.2003.1110503.x","article-title":"Colonization of hospital water systems by legionellae, mycobacteria and other heterotrophic bacteria potentially hazardous to risk group patients","volume":"111","author":"Kusnetsov","year":"2003","journal-title":"APMIS"},{"issue":"17","key":"10.1016\/j.watres.2018.11.032_bib22","doi-asserted-by":"crossref","first-page":"4868","DOI":"10.1016\/j.watres.2010.07.032","article-title":"Overnight stagnation of drinking water in household taps induces microbial growth and changes in community composition","volume":"44","author":"Lautenschlager","year":"2010","journal-title":"Water Res."},{"issue":"5","key":"10.1016\/j.watres.2018.11.032_bib23","doi-asserted-by":"crossref","first-page":"620","DOI":"10.1080\/09593330.2013.839748","article-title":"Microbiological tap water profile of a medium-sized building and effect of water stagnation","volume":"35","author":"Lipphaus","year":"2014","journal-title":"Environ. Technol."},{"issue":"1\u20132","key":"10.1016\/j.watres.2018.11.032_bib24","first-page":"51","article-title":"Estudio sobre la efectividad para la prevenci\u00f3n de la legionelosis del sistema de calentamiento instant\u00e1neo, instalado en la red de agua sanitaria de un hospital","volume":"6","author":"L\u00f3pez","year":"2006","journal-title":"Rev. Salud Ambient."},{"issue":"1\u20132","key":"10.1016\/j.watres.2018.11.032_bib25","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1016\/j.ijheh.2007.02.004","article-title":"Occurrence of Legionella in hot water systems of single-family residences in suburbs of two German cities with special reference to solar and district heating","volume":"211","author":"Mathys","year":"2008","journal-title":"Int. J. Hyg Environ. Health"},{"key":"10.1016\/j.watres.2018.11.032_bib26","series-title":"R: a Language and Environment for Statistical Computing","author":"R core team","year":"2013"},{"key":"10.1016\/j.watres.2018.11.032_bib27","unstructured":"Real Decreto 865\/2003, de 4 de julio, por el que se establecen los criterios higi\u00e9nico-sanitarios para la prevenci\u00f3n y control de la legionelosis. Bolet\u00edn Oficial del Estado. Madrid, 18 de julio de 2003, n\u00fam 171, pp. 28055-28069."},{"issue":"6","key":"10.1016\/j.watres.2018.11.032_bib28","doi-asserted-by":"crossref","first-page":"1842","DOI":"10.1128\/aem.60.6.1842-1851.1994","article-title":"Influence of plumbing materials on biofilm formation and growth of Legionella pneumophila in potable water systems","volume":"60","author":"Rogers","year":"1994","journal-title":"Appl. Environ. Microbiol."},{"issue":"2","key":"10.1016\/j.watres.2018.11.032_bib29","doi-asserted-by":"crossref","first-page":"396","DOI":"10.1128\/aem.52.2.396-399.1986","article-title":"Susceptibility of members of the family Legionellaceae to thermal stress: implications for heat eradication methods in water distribution systems","volume":"52","author":"Stout","year":"1986","journal-title":"Appl. Environ. Microbiol."},{"issue":"8","key":"10.1016\/j.watres.2018.11.032_bib30","doi-asserted-by":"crossref","first-page":"563","DOI":"10.1086\/502251","article-title":"Experiences of the first 16 hospitals using copper-silver ionization for Legionella control: implications for the evaluation of other disinfection modalities","volume":"24","author":"Stout","year":"2003","journal-title":"Infect. Control Hosp. Epidemiol."},{"issue":"3","key":"10.1016\/j.watres.2018.11.032_bib31","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1086\/664047","article-title":"Electronic-eye faucets: Legionella species contamination in healthcare settings","volume":"33","author":"Sydnor","year":"2012","journal-title":"Infect. Control Hosp. Epidemiol."},{"issue":"1","key":"10.1016\/j.watres.2018.11.032_bib32","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1016\/j.jhin.2017.08.021","article-title":"Rate of Legionella pneumophila colonization in hospital hot water network after time flow taps installation","volume":"98","author":"Totaro","year":"2018","journal-title":"J.\u00a0Hosp. Infect."},{"key":"10.1016\/j.watres.2018.11.032_bib33","series-title":"Field Testing Hot Water Temperature Reduction as an Energy-saving Measure\u2013does the Legionella Presence Change in a Clinic's","author":"V\u00f6lker","year":"2015"}],"container-title":["Water Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0043135418309539?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0043135418309539?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,23]],"date-time":"2025-09-23T01:57:03Z","timestamp":1758592623000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0043135418309539"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,2]]},"references-count":33,"alternative-id":["S0043135418309539"],"URL":"https:\/\/doi.org\/10.1016\/j.watres.2018.11.032","relation":{},"ISSN":["0043-1354"],"issn-type":[{"value":"0043-1354","type":"print"}],"subject":[],"published":{"date-parts":[[2019,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Role of hot water temperature and water system use on Legionella control in a tertiary hospital: An 8-year longitudinal study","name":"articletitle","label":"Article Title"},{"value":"Water Research","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.watres.2018.11.032","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2018 Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}