{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,28]],"date-time":"2026-10-28T19:09:50Z","timestamp":1793214590192,"version":"4.5.0"},"reference-count":33,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2022,4,28]],"date-time":"2022-04-28T00:00:00Z","timestamp":1651104000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["World j. otorhinolaryngol.-head neck surg."],"published-print":{"date-parts":[[2023,3]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>Harmonic Focus (Ethicon, Johnson and Johnson, Cincinnati, OH, USA), LigaSure Small Jaw (Medtronic, Covidien Products, Minneapolis, MN, USA), and Thunderbeat Open Fine Jaw (Olympus, Japan) are electrosurgical instruments used widely in head and neck surgery. The study aims to compare device malfunctions, adverse events to patients, operative injuries, and interventions related to Harmonic, LigaSure, and Thunderbeat use during thyroidectomy.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>The US Food and Drug Administration's Manufacture and User Facility Device Experience (MAUDE) database was queried for adverse events associated with Harmonic, LigaSure, and Thunderbeat from January 2005 to August 2020. Data were extracted from reports pertaining to thyroidectomy.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Of the 620 adverse events extracted, 394 (63.5%) involved Harmonic, 134 (21.6%) LigaSure, and 92 (14.8%) Thunderbeat. The reported device malfunctions most frequently associated with Harmonic was damage to the blade (110 (27.9%)), LigaSure was inappropriate function (47 (43.1%)), Thunderbeat was damage to the tissue or Teflon pad (27 (30.7%)), respectively. Burn injury and incomplete hemostasis were the most commonly reported adverse events. The operative injury reported most frequently when using Harmonic and LigaSure was burn injury. No operator injuries were reported with Thunderbeat use.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>The most frequently reported device malfunctions were damage to the blade, inappropriate function, and damage to the tissue or Teflon pad. The most frequently reported adverse events to patients was a burn injury and incomplete hemostasis. Interventions aimed at improving physician education may help reduce adverse events attributed to improper use.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1016\/j.wjorl.2021.04.008","type":"journal-article","created":{"date-parts":[[2021,6,29]],"date-time":"2021-06-29T02:04:11Z","timestamp":1624932251000},"page":"35-44","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":14,"title":["Complications associated with energy\u2010based devices during thyroidectomy from 2010\u20132020"],"prefix":"10.1002","volume":"9","author":[{"given":"Esther","family":"Lee","sequence":"first","affiliation":[{"name":"Division of Otolaryngology\u2010Head and Neck Surgery George Washington University School of Medicine &amp; Health Sciences  Washington DC USA"},{"name":"Western University of Health Sciences  Pomona CA USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jane Y.","family":"Tong","sequence":"additional","affiliation":[{"name":"Department of Otolaryngology\u2010Head and Neck Surgery Drexel University College of Medicine  Philadelphia PA USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luke J.","family":"Pasick","sequence":"additional","affiliation":[{"name":"Department of Otolaryngology\u2010Head and Neck Surgery University of Miami Miller School of Medicine  Miami FL USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel A.","family":"Benito","sequence":"additional","affiliation":[{"name":"Division of Otolaryngology\u2010Head and Neck Surgery George Washington University School of Medicine &amp; Health Sciences  Washington DC USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Arjun","family":"Joshi","sequence":"additional","affiliation":[{"name":"Division of Otolaryngology\u2010Head and Neck Surgery George Washington University School of Medicine &amp; Health Sciences  Washington DC USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Punam G.","family":"Thakkar","sequence":"additional","affiliation":[{"name":"Division of Otolaryngology\u2010Head and Neck Surgery George Washington University School of Medicine &amp; Health Sciences  Washington DC USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joseph F.","family":"Goodman","sequence":"additional","affiliation":[{"name":"Division of Otolaryngology\u2010Head and Neck Surgery George Washington University School of Medicine &amp; Health Sciences  Washington DC USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2022,4,28]]},"reference":[{"key":"e_1_2_8_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.cursur.2003.07.021"},{"key":"e_1_2_8_3_1","unstructured":"WeissAJ BaileyMK O'MalleyL BarrettML ElixhauserA SteinerCA.Patient characteristics of opioid\u2010related inpatient stays and emergency department visits nationally and by state 2014: statistical brief #224. 2017. In: Healthcare Cost and Utilization Project (HCUP) Statistical Briefs [Internet]. Rockville (MD): Agency for Healthcare Research and Quality (US); 2006 Feb\u2013.https:\/\/hcup-us.ahrq.gov\/reports\/statbriefs\/sb224-Patient-Characteristics-Opioid-Hospital-Stays-ED-Visits-by-State.pdf"},{"key":"e_1_2_8_4_1","doi-asserted-by":"publisher","DOI":"10.1007\/s12262-015-1317-5"},{"key":"e_1_2_8_5_1","doi-asserted-by":"publisher","DOI":"10.21037\/gs.2016.09.01"},{"key":"e_1_2_8_6_1","doi-asserted-by":"publisher","DOI":"10.21037\/gs.2019.08.05"},{"key":"e_1_2_8_7_1","doi-asserted-by":"publisher","DOI":"10.21037\/gs.2020.03.31"},{"key":"e_1_2_8_8_1","doi-asserted-by":"publisher","DOI":"10.1007\/s13304-020-00776-9"},{"key":"e_1_2_8_9_1","doi-asserted-by":"publisher","DOI":"10.3390\/medicina56120651"},{"key":"e_1_2_8_10_1","unstructured":"Ethicon. Harmonic focus\u00ae+ shears[EB\/OL]. [2021\u201003\u201027].https:\/\/www.jnjmedicaldevices.com\/en-US\/product\/harmonic-focus-shears"},{"key":"e_1_2_8_11_1","unstructured":"Medtronic. LigaSureTM Technology[EB\/OL]. [2021\u201003\u201027].https:\/\/www.medtronic.com\/covidien\/en-us\/products\/vessel-sealing\/ligasure-technology.html"},{"key":"e_1_2_8_12_1","unstructured":"Olympus. Thunderbeat Open Fine Jaw\u2010Olympus Medical Systems[EB\/OL]. [2021\u201003\u201027].https:\/\/www.olympus-europa.com\/medical\/en\/Products-and-Solutions\/Products\/Product\/THUNDERBEAT-Open-Fine-Jaw.html"},{"key":"e_1_2_8_13_1","unstructured":"RiggsMKA novel approach to assess minimally invasive surgical device failure utilizing adverse event outcome severity and design complexity.Published online2017.https:\/\/ir.library.louisville.edu\/cgi\/viewcontent.cgi?article=3972%26context=etd"},{"key":"e_1_2_8_14_1","doi-asserted-by":"publisher","DOI":"10.1186\/s12957-018-1448-9"},{"key":"e_1_2_8_15_1","doi-asserted-by":"publisher","DOI":"10.1177\/0194599819865248"},{"key":"e_1_2_8_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjoto.2020.102826"},{"key":"e_1_2_8_17_1","doi-asserted-by":"publisher","DOI":"10.1055\/s-0040-1716858"},{"key":"e_1_2_8_18_1","doi-asserted-by":"publisher","DOI":"10.1177\/0194599820938743"},{"key":"e_1_2_8_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjoto.2020.102616"},{"key":"e_1_2_8_20_1","unstructured":"Olympus. Thunderbeat Instruction Manual[EB\/OL]. [2021\u201003\u201027].https:\/\/mercyor.files.wordpress.com\/2016\/06\/thunderbeat-handpiece-users-manual.pdf"},{"key":"e_1_2_8_21_1","unstructured":"Olympus. Thunderbeat[EB\/OL]. [2021\u201003\u201027].https:\/\/www.olympus-europa.com\/medical\/en\/Products-and-Solutions\/Products\/Product\/THUNDERBEAT-General-Surgery.html"},{"key":"e_1_2_8_22_1","doi-asserted-by":"publisher","DOI":"10.1007\/s004649900769"},{"key":"e_1_2_8_23_1","doi-asserted-by":"publisher","DOI":"10.4293\/108680812X13291597716348"},{"key":"e_1_2_8_24_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.otc.2016.03.006"},{"key":"e_1_2_8_25_1","doi-asserted-by":"publisher","DOI":"10.21037\/gs.2020.02.05"},{"key":"e_1_2_8_26_1","doi-asserted-by":"publisher","DOI":"10.1586\/erd.13.6"},{"key":"e_1_2_8_27_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.otohns.2010.03.018"},{"key":"e_1_2_8_28_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00423-016-1448-6"},{"key":"e_1_2_8_29_1","doi-asserted-by":"publisher","DOI":"10.1177\/1457496919828237"},{"key":"e_1_2_8_30_1","doi-asserted-by":"publisher","DOI":"10.1108\/14684520810866010"},{"key":"e_1_2_8_31_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00464-013-2823-9"},{"key":"e_1_2_8_32_1","doi-asserted-by":"publisher","DOI":"10.3329\/bmrcb.v34i3.1973"},{"key":"e_1_2_8_33_1","doi-asserted-by":"publisher","DOI":"10.1002\/hed.21970"},{"key":"e_1_2_8_34_1","unstructured":"BeckCE EakinJL MikamiD. Best Training Improves the Understanding and Safety of Electrosurgery Use in the Operating Room. 25 Nov. 2020.https:\/\/www.sages.org\/meetings\/annual-meeting\/abstracts-archive\/best-training-improves-the-understanding-and-safety-of-electrosurgery-use-in-the-operating-room\/"}],"container-title":["World Journal of Otorhinolaryngology - Head and Neck Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2095881121000512?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2095881121000512?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.wjorl.2021.04.008","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1016\/j.wjorl.2021.04.008","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/j.wjorl.2021.04.008","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,22]],"date-time":"2023-08-22T04:17:58Z","timestamp":1692677878000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1016\/j.wjorl.2021.04.008"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,4,28]]},"references-count":33,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2023,3]]}},"alternative-id":["10.1016\/j.wjorl.2021.04.008"],"URL":"https:\/\/doi.org\/10.1016\/j.wjorl.2021.04.008","archive":["Portico"],"relation":{},"ISSN":["2095-8811","2589-1081"],"issn-type":[{"value":"2095-8811","type":"print"},{"value":"2589-1081","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,4,28]]},"assertion":[{"value":"2021-03-27","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-04-28","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}