{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,11]],"date-time":"2026-08-11T07:16:45Z","timestamp":1786432605546,"version":"build-2736575974"},"reference-count":33,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2016,11,1]],"date-time":"2016-11-01T00:00:00Z","timestamp":1477958400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2016,8,19]],"date-time":"2016-08-19T00:00:00Z","timestamp":1471564800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","worldneurosurgery.org","clinicalkey.es","clinicalkey.com.au","clinicalkey.fr","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["World Neurosurgery"],"published-print":{"date-parts":[[2016,11]]},"DOI":"10.1016\/j.wneu.2016.07.101","type":"journal-article","created":{"date-parts":[[2016,8,9]],"date-time":"2016-08-09T20:21:59Z","timestamp":1470774119000},"page":"229-240","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":35,"special_numbering":"C","title":["The DERIVO Embolization Device in the Treatment of Intracranial Aneurysms: Short- and Midterm Results"],"prefix":"10.1016","volume":"95","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0020-3759","authenticated-orcid":false,"given":"Erol","family":"Akgul","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hasan Bilen","family":"Onan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Suha","family":"Akpinar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Huseyin Tugsan","family":"Balli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Erol Huseyin","family":"Aksungur","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.wneu.2016.07.101_bib1","doi-asserted-by":"crossref","first-page":"909","DOI":"10.1007\/s00234-008-0446-y","article-title":"Materials and techniques for coiling of cerebral aneurysms: how much scientific evidence do we have?","volume":"50","author":"Kurre","year":"2008","journal-title":"Neuroradiology"},{"key":"10.1016\/j.wneu.2016.07.101_bib2","doi-asserted-by":"crossref","first-page":"1398","DOI":"10.1161\/01.STR.0000073841.88563.E9","article-title":"Long-term angiographic recurrences after selective endovascular treatment of aneurysms with detachable coils","volume":"34","author":"Raymond","year":"2003","journal-title":"Stroke"},{"key":"10.1016\/j.wneu.2016.07.101_bib3","doi-asserted-by":"crossref","first-page":"1145","DOI":"10.1007\/s00234-012-1047-3","article-title":"Italian multicenter experience with flow-diverter devices for intracranial unruptured aneurysm treatment with periprocedural complications\u2013a retrospective data analysis","volume":"54","author":"Briganti","year":"2012","journal-title":"Neuroradiology"},{"key":"10.1016\/j.wneu.2016.07.101_bib4","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1371\/journal.pone.0012492","article-title":"Early experience in the treatment of intra-cranial aneurysms by endovascular flow diversion: a multicentre prospective study","volume":"5","author":"Byrne","year":"2010","journal-title":"PLoS One"},{"key":"10.1016\/j.wneu.2016.07.101_bib5","doi-asserted-by":"crossref","first-page":"1158","DOI":"10.3171\/2014.1.JNS131442","article-title":"Flow Re-direction Endoluminal Device in treatment of cerebral aneurysms: initial experience with short-term follow-up results","volume":"120","author":"Kocer","year":"2014","journal-title":"J\u00a0Neurosurg"},{"key":"10.1016\/j.wneu.2016.07.101_bib6","doi-asserted-by":"crossref","first-page":"1567","DOI":"10.1161\/STROKEAHA.111.000434","article-title":"New generation of flow diverter (surpass) for unruptured intracranial aneurysms: a prospective single-center study in 37 patients","volume":"44","author":"De Vries","year":"2013","journal-title":"Stroke"},{"key":"10.1016\/j.wneu.2016.07.101_bib7","doi-asserted-by":"crossref","first-page":"116","DOI":"10.1136\/jnis.2011.004911","article-title":"A\u00a0single center comparison of coiling versus stent assisted coiling in 90 consecutive paraophthalmic region aneurysms","volume":"4","author":"Colby","year":"2012","journal-title":"J\u00a0Neurointerv Surg"},{"key":"10.1016\/j.wneu.2016.07.101_bib8","doi-asserted-by":"crossref","first-page":"632","DOI":"10.1227\/01.NEU.0000339109.98070.65","article-title":"Curative endovascular reconstruction of cerebral aneurysms with the pipeline embolization device: the Buenos Aires experience","volume":"64","author":"Lylyk","year":"2009","journal-title":"Neurosurgery"},{"key":"10.1016\/j.wneu.2016.07.101_bib9","first-page":"154","article-title":"Endovascular treatment of cranial aneurysms with the pipeline flow-diverting stent: preliminary mid-term results","volume":"19","author":"Cinar","year":"2013","journal-title":"Diagn Interv Radiol"},{"key":"10.1016\/j.wneu.2016.07.101_bib10","doi-asserted-by":"crossref","first-page":"1436","DOI":"10.3174\/ajnr.A3246","article-title":"Treatment of intracranial aneurysms using the pipeline flow-diverter embolization device: a single-center experience with long-term follow-up results","volume":"33","author":"Saatci","year":"2012","journal-title":"AJNR Am J Neuroradiol"},{"key":"10.1016\/j.wneu.2016.07.101_bib11","doi-asserted-by":"crossref","first-page":"1150","DOI":"10.3174\/ajnr.A2907","article-title":"Flow-diverter silk stent for the treatment of intracranial aneurysms: 1-year follow-up in a multicenter study","volume":"33","author":"Berge","year":"2012","journal-title":"AJNR Am J Neuroradiol"},{"key":"10.1016\/j.wneu.2016.07.101_bib12","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1136\/neurintsurg-2012-010299","article-title":"Immediate procedural outcomes in 35 consecutive pipeline embolization cases: a single-center, single-user experience","volume":"5","author":"Colby","year":"2013","journal-title":"J\u00a0Neurointerv Surg"},{"key":"10.1016\/j.wneu.2016.07.101_bib13","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1227\/01.neu.0000430297.17961.f1","article-title":"Flow-diverter devices for intracranial aneurysms: systematic review and meta-analysis","volume":"73","author":"Arrese","year":"2013","journal-title":"Neurosurgery"},{"key":"10.1016\/j.wneu.2016.07.101_bib14","doi-asserted-by":"crossref","first-page":"442","DOI":"10.1161\/STROKEAHA.112.678151","article-title":"Endovascular treatment of intracranial aneurysms with flow diverters: a meta-analysis","volume":"44","author":"Brinjikji","year":"2013","journal-title":"Stroke"},{"key":"10.1016\/j.wneu.2016.07.101_bib15","doi-asserted-by":"crossref","first-page":"487","DOI":"10.3174\/ajnr.A2797","article-title":"Immediate and midterm results following treatment of recently ruptured intracranial aneurysms with the Pipeline embolization device","volume":"33","author":"McAuliffe","year":"2012","journal-title":"AJNR Am J Neuroradiol"},{"key":"10.1016\/j.wneu.2016.07.101_bib16","doi-asserted-by":"crossref","first-page":"164","DOI":"10.3174\/ajnr.A2727","article-title":"Immediate and midterm results following treatment of unruptured intracranial aneurysms with the pipeline embolization device","volume":"33","author":"McAuliffe","year":"2012","journal-title":"AJNR Am J Neuroradiol"},{"key":"10.1016\/j.wneu.2016.07.101_bib17","doi-asserted-by":"crossref","first-page":"357","DOI":"10.1177\/159101991101700313","article-title":"Acute endovascular treatment (< 48 hours) of uncoilable ruptured aneurysms at non-branching sites using silk flow-diverting devices","volume":"17","author":"Causin","year":"2011","journal-title":"Interv Neuroradiol"},{"key":"10.1016\/j.wneu.2016.07.101_bib18","doi-asserted-by":"crossref","first-page":"413","DOI":"10.1177\/159101991201800407","article-title":"Complications in the treatment of intracranial aneurysms with silk stents: an analysis of 30 consecutive patients","volume":"18","author":"Cirillo","year":"2012","journal-title":"Interv Neuroradiol"},{"key":"10.1016\/j.wneu.2016.07.101_bib19","doi-asserted-by":"crossref","first-page":"98","DOI":"10.3174\/ajnr.A4078","article-title":"Surpass flow diverter in the treatment of intracranial aneurysms: a prospective multicenter study","volume":"36","author":"Wakhloo","year":"2015","journal-title":"AJNR Am J Neuroradiol"},{"key":"10.1016\/j.wneu.2016.07.101_bib20","doi-asserted-by":"crossref","first-page":"364","DOI":"10.1227\/NEU.0000000000000431","article-title":"Pipeline embolization device for the treatment of intra- and extracranial fusiform and dissecting aneurysms: initial experience and long-term follow-up","volume":"75","author":"Fischer","year":"2014","journal-title":"Neurosurgery"},{"key":"10.1016\/j.wneu.2016.07.101_bib21","doi-asserted-by":"crossref","first-page":"789","DOI":"10.1227\/01.NEU.0000372920.39101.55","article-title":"Effect of flow diversion treatment on very small ruptured aneurysms","volume":"67","author":"Kulcsar","year":"2010","journal-title":"Neurosurgery"},{"key":"10.1016\/j.wneu.2016.07.101_bib22","doi-asserted-by":"crossref","first-page":"1","DOI":"10.3389\/fneur.2014.00021","article-title":"Flow-diversion panacea or poison?","volume":"5","author":"Zanaty","year":"2014","journal-title":"Front Neurol"},{"key":"10.1016\/j.wneu.2016.07.101_bib23","doi-asserted-by":"crossref","first-page":"408","DOI":"10.3171\/2012.10.JNS112222","article-title":"Midterm and long-term follow-up of cerebral aneurysms treated with flow diverter devices: a single-center experience","volume":"118","author":"Piano","year":"2013","journal-title":"J\u00a0Neurosurg"},{"key":"10.1016\/j.wneu.2016.07.101_bib24","doi-asserted-by":"crossref","unstructured":"Ley D, Muhl-Benninghaus R, Yilmaz U, Korner H, Cattaneo GF, Mailander W, et\u00a0al. The Derivo Embolization Device, a second-generation flow diverter for the treatment of intracranial aneurysms, evaluated in an elastase-induced aneurysm model. Clin Neuroradiol., 2015 [Epub ahead of print].","DOI":"10.1007\/s00062-015-0493-9"},{"key":"10.1016\/j.wneu.2016.07.101_bib25","unstructured":"Acandis. DERIVO Embolisation Device. Available at: http:\/\/www.acandis.com\/derivo-embolisation-device-13-en. Accessed February 25,\u00a02016."},{"key":"10.1016\/j.wneu.2016.07.101_bib26","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1016\/j.wneu.2011.02.015","article-title":"Pipeline flow-diverter stent for endovascular treatment of intracranial aneurysms: preliminary experience in 20 patients with 27 aneurysms","volume":"76","author":"Lubicz","year":"2011","journal-title":"World Neurosurg"},{"key":"10.1016\/j.wneu.2016.07.101_bib27","doi-asserted-by":"crossref","first-page":"1032","DOI":"10.1161\/STROKEAHA.111.636019","article-title":"Flow diverters at and beyond the level of the circle of willis for the treatment of intracranial aneurysms","volume":"43","author":"Pistocchi","year":"2012","journal-title":"Stroke"},{"key":"10.1016\/j.wneu.2016.07.101_bib28","doi-asserted-by":"crossref","first-page":"295","DOI":"10.1007\/s00062-012-0178-6","article-title":"Pipeline embolization device for intracranial aneurysm: a systematic review","volume":"22","author":"Leung","year":"2012","journal-title":"Clin Neuroradiol"},{"key":"10.1016\/j.wneu.2016.07.101_bib29","doi-asserted-by":"crossref","first-page":"709","DOI":"10.1007\/s00234-011-0949-9","article-title":"Treatment of intracranial aneurysms. Reconstruction of the parent artery with flow-diverting (Silk) stent","volume":"54","author":"Wagner","year":"2012","journal-title":"Neuroradiology"},{"key":"10.1016\/j.wneu.2016.07.101_bib30","doi-asserted-by":"crossref","first-page":"1355","DOI":"10.1007\/s00234-012-1051-7","article-title":"Early and midterm results of complex cerebral aneurysms treated with Silk stent","volume":"54","author":"Velioglu","year":"2012","journal-title":"Neuroradiology"},{"key":"10.1016\/j.wneu.2016.07.101_bib31","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1007\/s00234-013-1302-2","article-title":"Delayed ipsilateral parenchymal hemorrhage following treatment of intracranial aneurysms with flow diverter","volume":"56","author":"Tomas","year":"2014","journal-title":"Neuroradiology"},{"key":"10.1016\/j.wneu.2016.07.101_bib32","doi-asserted-by":"crossref","first-page":"1389","DOI":"10.3174\/ajnr.A1070","article-title":"Dual antiplatelet therapy monitoring for neurointerventional procedures using a point-of-care platelet function test: a single-center experience","volume":"29","author":"Lee","year":"2008","journal-title":"AJNR Am J Neuroradiol"},{"key":"10.1016\/j.wneu.2016.07.101_bib33","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1016\/j.jocn.2013.07.006","article-title":"The SILK flow diverter in the treatment of intracranial aneurysms","volume":"21","author":"Murthy","year":"2014","journal-title":"J\u00a0Clin Neurosci"}],"container-title":["World Neurosurgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1878875016306477?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1878875016306477?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2018,9,9]],"date-time":"2018-09-09T05:53:41Z","timestamp":1536472421000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1878875016306477"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,11]]},"references-count":33,"alternative-id":["S1878875016306477"],"URL":"https:\/\/doi.org\/10.1016\/j.wneu.2016.07.101","relation":{},"ISSN":["1878-8750"],"issn-type":[{"value":"1878-8750","type":"print"}],"subject":[],"published":{"date-parts":[[2016,11]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"The DERIVO Embolization Device in the Treatment of Intracranial Aneurysms: Short- and Midterm Results","name":"articletitle","label":"Article Title"},{"value":"World Neurosurgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.wneu.2016.07.101","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2016 The Authors. Published by Elsevier Inc.","name":"copyright","label":"Copyright"}]}}