{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,5]],"date-time":"2026-01-05T22:29:58Z","timestamp":1767652198439,"version":"3.40.5"},"reference-count":33,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2017,10,1]],"date-time":"2017-10-01T00:00:00Z","timestamp":1506816000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","worldneurosurgery.org","clinicalkey.es","clinicalkey.com.au","clinicalkey.fr","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["World Neurosurgery"],"published-print":{"date-parts":[[2017,10]]},"DOI":"10.1016\/j.wneu.2017.07.079","type":"journal-article","created":{"date-parts":[[2017,7,20]],"date-time":"2017-07-20T15:33:13Z","timestamp":1500564793000},"page":"932-938","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":9,"special_numbering":"C","title":["Finite Element Analysis of Influence of Axial Position of Center of Rotation of a Cervical Total Disc Replacement on Biomechanical Parameters: Simulated 2-Level Replacement Based on a Validated Model"],"prefix":"10.1016","volume":"106","author":[{"given":"Yang","family":"Li","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4016-569X","authenticated-orcid":false,"given":"Zhenjun","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhenhua","family":"Liao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhongjun","family":"Mo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Weiqiang","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.wneu.2017.07.079_bib1","first-page":"229","article-title":"Anterior cervical plating enhances arthrodesis after discectomy and fusion with cortical allograft","volume":"50","author":"Kaiser","year":"2002","journal-title":"Neurosurgery"},{"key":"10.1016\/j.wneu.2017.07.079_bib2","doi-asserted-by":"crossref","first-page":"1756","DOI":"10.1097\/01.brs.0000172148.86756.ce","article-title":"Is autograft the gold standard in achieving radiographic fusion in one-level anterior cervical discectomy and fusion with rigid anterior plate fixation?","volume":"30","author":"Samartzis","year":"2005","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.1016\/j.wneu.2017.07.079_bib3","doi-asserted-by":"crossref","first-page":"198","DOI":"10.3171\/spi.2007.6.3.198","article-title":"Clinical and radiographic analysis of cervical disc arthroplasty compared with allograft fusion: a randomized controlled clinical trial","volume":"6","author":"Mummaneni","year":"2007","journal-title":"J\u00a0Neurosurg Spine"},{"key":"10.1016\/j.wneu.2017.07.079_bib4","doi-asserted-by":"crossref","first-page":"447","DOI":"10.3171\/spi.2006.4.6.447","article-title":"Subsidence of the Wing titanium cage after anterior cervical interbody fusion: 2-year follow-up study","volume":"4","author":"Schmieder","year":"2006","journal-title":"J\u00a0Neurosurg Spine"},{"key":"10.1016\/j.wneu.2017.07.079_bib5","doi-asserted-by":"crossref","first-page":"3","DOI":"10.5435\/JAAOS-21-01-3","article-title":"Adjacent segment disease following cervical spine surgery","volume":"21","author":"Cho","year":"2013","journal-title":"J\u00a0Am Acad Orthop Surg"},{"key":"10.1016\/j.wneu.2017.07.079_bib6","doi-asserted-by":"crossref","first-page":"e35032","DOI":"10.1371\/journal.pone.0035032","article-title":"The incidence of adjacent segment degeneration after cervical disc arthroplasty (CDA): a meta analysis of randomized controlled trials","volume":"7","author":"Yang","year":"2012","journal-title":"PLoS One"},{"key":"10.1016\/j.wneu.2017.07.079_bib7","doi-asserted-by":"crossref","first-page":"1380","DOI":"10.1016\/j.wneu.2013.09.022","article-title":"Surgical complications of anterior cervical diskectomy and fusion for cervical degenerative disk disease: a single surgeon's experience of 1,576 patients","volume":"82","author":"Nanda","year":"2014","journal-title":"World Neurosurg"},{"key":"10.1016\/j.wneu.2017.07.079_bib8","doi-asserted-by":"crossref","first-page":"2310","DOI":"10.1097\/BRS.0b013e318154c57e","article-title":"Anterior cervical discectomy and fusion associated complications","volume":"32","author":"Fountas","year":"2007","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.1016\/j.wneu.2017.07.079_bib9","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1016\/j.spinee.2010.01.006","article-title":"Biomechanical comparison of single- and two-level cervical arthroplasty versus arthrodesis: effect on adjacent-level spinal kinematics","volume":"10","author":"Cunningham","year":"2010","journal-title":"Spine J"},{"key":"10.1016\/j.wneu.2017.07.079_bib10","doi-asserted-by":"crossref","first-page":"1932","DOI":"10.1097\/BRS.0b013e3181fc1aff","article-title":"Disc replacement adjacent to cervical fusion: a biomechanical comparison of hybrid construct versus two-level fusion","volume":"36","author":"Lee","year":"2011","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.1016\/j.wneu.2017.07.079_bib11","doi-asserted-by":"crossref","first-page":"1769","DOI":"10.1097\/BRS.0b013e3181c225fa","article-title":"Biomechanical analysis of the range of motion after placement of a two-level cervical ProDisc-C versus hybrid construct","volume":"35","author":"Cho","year":"2010","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.1016\/j.wneu.2017.07.079_bib12","doi-asserted-by":"crossref","first-page":"40","DOI":"10.3171\/SPI-07\/07\/040","article-title":"Range of motion change after cervical arthroplasty with ProDisc-C and Prestige artificial discs compared with anterior cervical discectomy and fusion","volume":"7","author":"Chang","year":"2007","journal-title":"J\u00a0Neurosurg Spine"},{"key":"10.1016\/j.wneu.2017.07.079_bib13","doi-asserted-by":"crossref","first-page":"1578","DOI":"10.1097\/BRS.0000000000001044","article-title":"Biomechanical analysis of cervical disc replacement and fusion using single level, two level, and hybrid constructs","volume":"40","author":"Gandhi","year":"2015","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.1016\/j.wneu.2017.07.079_bib14","doi-asserted-by":"crossref","first-page":"1640","DOI":"10.1016\/j.spinee.2013.06.026","article-title":"Biomechanical evaluation of a metal-on-metal cervical intervertebral disc prosthesis","volume":"13","author":"Colle","year":"2013","journal-title":"Spine J"},{"key":"10.1016\/j.wneu.2017.07.079_bib15","doi-asserted-by":"crossref","first-page":"432","DOI":"10.1007\/s00586-011-1974-4","article-title":"Cervical disc prosthesis versus arthrodesis using one-level, hybrid and two-level constructs: an in\u00a0vitro investigation","volume":"21","author":"Barrey","year":"2012","journal-title":"Eur Spine J"},{"key":"10.1016\/j.wneu.2017.07.079_bib16","doi-asserted-by":"crossref","first-page":"1095","DOI":"10.1016\/j.clinbiomech.2008.06.002","article-title":"Biomechanical studies on cervical total disc arthroplasty: a literature review","volume":"23","author":"Galbusera","year":"2008","journal-title":"Clin Biomech"},{"key":"10.1016\/j.wneu.2017.07.079_bib17","doi-asserted-by":"crossref","first-page":"397","DOI":"10.1016\/j.clinbiomech.2010.01.010","article-title":"The influence of the axial, antero-posterior and lateral positions of the center of rotation of a ball-and-socket disc prosthesis on the cervical spine biomechanics","volume":"25","author":"Galbusera","year":"2010","journal-title":"Clin Biomech"},{"key":"10.1016\/j.wneu.2017.07.079_bib18","doi-asserted-by":"crossref","first-page":"700","DOI":"10.1097\/BRS.0b013e3181f5cb87","article-title":"Comparison of cervical spine biomechanics after fixed- and mobile-core artificial disc replacement: a finite element analysis","volume":"36","author":"Lee","year":"2011","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.1016\/j.wneu.2017.07.079_bib19","doi-asserted-by":"crossref","first-page":"E469","DOI":"10.1097\/BRS.0000000000000818","article-title":"Does location of rotation center in artificial disc affect cervical biomechanics?","volume":"40","author":"Mo","year":"2015","journal-title":"Spine (Phila Pa 1976)"},{"issue":"suppl 5","key":"10.1016\/j.wneu.2017.07.079_bib20","doi-asserted-by":"crossref","first-page":"S653","DOI":"10.1007\/s00586-009-1211-6","article-title":"Do design variations in the artificial disc influence cervical spine biomechanics? A finite element investigation","volume":"21","author":"Faizan","year":"2012","journal-title":"Eur Spine J"},{"key":"10.1016\/j.wneu.2017.07.079_bib21","doi-asserted-by":"crossref","first-page":"E285","DOI":"10.1097\/BRS.0b013e3181c88165","article-title":"Analysis of segmental cervical spine vertebral motion after Prodisc-C cervical disc replacement","volume":"35","author":"Park","year":"2010","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.1016\/j.wneu.2017.07.079_bib22","doi-asserted-by":"crossref","DOI":"10.1097\/BRS.0000000000002128","article-title":"Biomechanical analysis of two-level cervical disc replacement with a stand-alone U-shaped disc implant [e-pub ahead of print]","author":"Li","year":"2017","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.1016\/j.wneu.2017.07.079_bib23","doi-asserted-by":"crossref","first-page":"1191","DOI":"10.1007\/s10237-015-0752-3","article-title":"Effect of mechanical loading on heterotopic ossification in cervical total disc replacement: a three-dimensional finite element analysis","volume":"15","author":"Ganbat","year":"2016","journal-title":"Biomech Model Mechanobiol"},{"key":"10.1016\/j.wneu.2017.07.079_bib24","doi-asserted-by":"crossref","first-page":"689","DOI":"10.1016\/S1350-4533(00)00002-3","article-title":"Finite element modeling of the cervical spine: role of intervertebral disc under axial and eccentric loads","volume":"21","author":"Kumaresan","year":"1999","journal-title":"Med Eng Phys"},{"key":"10.1016\/j.wneu.2017.07.079_bib25","doi-asserted-by":"crossref","first-page":"1181","DOI":"10.1007\/s00586-016-4777-9","article-title":"Biomechanical consideration of prosthesis selection in hybrid surgery for bi-level cervical disc degenerative diseases","volume":"26","author":"Mo","year":"2017","journal-title":"Eur Spine J"},{"key":"10.1016\/j.wneu.2017.07.079_bib26","doi-asserted-by":"crossref","first-page":"E893","DOI":"10.1097\/BRS.0000000000001468","article-title":"A\u00a0biomechanical analysis of an artificial disc with a shock-absorbing core property by using whole-cervical spine finite element analysis","volume":"41","author":"Lee","year":"2016","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.1016\/j.wneu.2017.07.079_bib27","doi-asserted-by":"crossref","first-page":"E237","DOI":"10.1097\/BSD.0000000000000185","article-title":"Prospective, randomized comparison of cervical total disk replacement versus anterior cervical fusion results at 48 months follow-up","volume":"28","author":"Hisey","year":"2015","journal-title":"J\u00a0Spinal Disord Tech"},{"key":"10.1016\/j.wneu.2017.07.079_bib28","doi-asserted-by":"crossref","first-page":"2263","DOI":"10.1007\/s00586-016-4431-6","article-title":"A\u00a0RCT comparing 7-year clinical outcomes of one level symptomatic cervical disc disease (SCDD) following ProDisc-C total disc arthroplasty (TDA) versus anterior cervical discectomy and fusion (ACDF)","volume":"25","author":"Loumeau","year":"2016","journal-title":"Eur Spine J"},{"key":"10.1016\/j.wneu.2017.07.079_bib29","doi-asserted-by":"crossref","first-page":"1738","DOI":"10.2106\/JBJS.N.01186","article-title":"ProDisc-C total disc replacement versus anterior cervical discectomy and fusion for single-level symptomatic cervical disc disease seven-year follow-up of the prospective randomized US Food and Drug Administration Investigational Device Exemption Study","volume":"97A","author":"Janssen","year":"2015","journal-title":"J\u00a0Bone Joint Surg Am"},{"key":"10.1016\/j.wneu.2017.07.079_bib30","doi-asserted-by":"crossref","first-page":"516","DOI":"10.3171\/2014.6.SPINE13996","article-title":"Clinical and radiographic analysis of an artificial cervical disc: 7-year follow-up from the Prestige prospective randomized controlled clinical trial","volume":"21","author":"Burkus","year":"2014","journal-title":"J\u00a0Neurosurg Spine"},{"key":"10.1016\/j.wneu.2017.07.079_bib31","doi-asserted-by":"crossref","first-page":"E794","DOI":"10.1097\/BRS.0b013e3181afe4bb","article-title":"Effect of two-level total disc replacement on cervical spine kinematics","volume":"34","author":"Phillips","year":"2009","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.1016\/j.wneu.2017.07.079_bib32","doi-asserted-by":"crossref","first-page":"819","DOI":"10.1007\/s12541-013-0107-x","article-title":"Biomechanical behavior of two different cervical total disc replacement designs in relation of concavity of articular surfaces: ProDisc-CA (R) vs. Prestige-LPA (R)","volume":"14","author":"Jung","year":"2013","journal-title":"Int J Precis Eng Man"},{"key":"10.1016\/j.wneu.2017.07.079_bib33","doi-asserted-by":"crossref","first-page":"244","DOI":"10.1016\/j.medengphy.2008.07.007","article-title":"Biomechanical comparison between lumbar disc arthroplasty and fusion","volume":"31","author":"Chen","year":"2009","journal-title":"Med Eng Phys"}],"container-title":["World Neurosurgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1878875017311798?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1878875017311798?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2019,10,1]],"date-time":"2019-10-01T01:30:47Z","timestamp":1569893447000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1878875017311798"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,10]]},"references-count":33,"alternative-id":["S1878875017311798"],"URL":"https:\/\/doi.org\/10.1016\/j.wneu.2017.07.079","relation":{},"ISSN":["1878-8750"],"issn-type":[{"type":"print","value":"1878-8750"}],"subject":[],"published":{"date-parts":[[2017,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Finite Element Analysis of Influence of Axial Position of Center of Rotation of a Cervical Total Disc Replacement on Biomechanical Parameters: Simulated 2-Level Replacement Based on a Validated Model","name":"articletitle","label":"Article Title"},{"value":"World Neurosurgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.wneu.2017.07.079","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2017 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}