{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,20]],"date-time":"2026-01-20T04:33:18Z","timestamp":1768883598799,"version":"3.49.0"},"reference-count":29,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2018,3,1]],"date-time":"2018-03-01T00:00:00Z","timestamp":1519862400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","worldneurosurgery.org","clinicalkey.es","clinicalkey.fr","clinicalkey.com.au","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["World Neurosurgery"],"published-print":{"date-parts":[[2018,3]]},"DOI":"10.1016\/j.wneu.2017.11.172","type":"journal-article","created":{"date-parts":[[2017,12,9]],"date-time":"2017-12-09T00:43:46Z","timestamp":1512780226000},"page":"e72-e81","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":17,"special_numbering":"C","title":["Heat Generation During Bony Decompression of Lumbar Spinal Stenosis Using a High-Speed Diamond Drill with or without Automated Irrigation and an Ultrasonic Bone-Cutting Knife: A Single-Blinded Prospective Randomized Controlled Study"],"prefix":"10.1016","volume":"111","author":[{"given":"Marc","family":"Matthes","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dirk Thomas","family":"Pillich","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ehab","family":"El Refaee","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Henry W.S.","family":"Schroeder","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jan-Uwe","family":"M\u00fcller","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.wneu.2017.11.172_bib1","doi-asserted-by":"crossref","first-page":"703","DOI":"10.1007\/s00402-008-0630-x","article-title":"Determination of spatial distribution of increase in bone temperature during drilling by infrared thermography: preliminary report","volume":"129","author":"Augustin","year":"2009","journal-title":"Arch Orthop Trauma Surg"},{"key":"10.1016\/j.wneu.2017.11.172_bib2","doi-asserted-by":"crossref","first-page":"284","DOI":"10.1097\/00003086-198406000-00044","article-title":"Thermally induced bone necrosis in rabbits. Relation to implant failure in humans","volume":"186","author":"Berman","year":"1984","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.wneu.2017.11.172_bib3","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1177\/000348947808700109","article-title":"Thermal injury from mastoid bone burrs","volume":"87","author":"Call","year":"1978","journal-title":"Ann Otol Rhinol Laryngol"},{"key":"10.1016\/j.wneu.2017.11.172_bib4","doi-asserted-by":"crossref","first-page":"741","DOI":"10.1016\/S1350-4533(01)00003-0","article-title":"Measurement of thermal conductivity of bovine cortical bone","volume":"22","author":"Davidson","year":"2000","journal-title":"Med Eng Phys"},{"key":"10.1016\/j.wneu.2017.11.172_bib5","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1016\/0165-0270(92)90073-M","article-title":"Hyperthermia-induced damage to rat sciatic nerve assessed in\u00a0vivo with functional methods and with electrophysiology","volume":"45","author":"de Vrind","year":"1992","journal-title":"J\u00a0Neurosci Methods"},{"key":"10.1016\/j.wneu.2017.11.172_bib6","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1016\/0022-3913(83)90174-9","article-title":"Temperature threshold levels for heat-induced bone tissue injury: a vital-microscopic study in the rabbit","volume":"50","author":"Eriksson","year":"1983","journal-title":"J\u00a0Prosthet Dent"},{"key":"10.1016\/j.wneu.2017.11.172_bib7","doi-asserted-by":"crossref","first-page":"629","DOI":"10.3109\/17453678408992410","article-title":"Heat caused by drilling cortical bone. Temperature measured in\u00a0vivo in patients and animals","volume":"55","author":"Eriksson","year":"1984","journal-title":"Acta Orthop Scand"},{"key":"10.1016\/j.wneu.2017.11.172_bib8","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1016\/0278-2391(86)90006-6","article-title":"Temperatures during drilling implants using the Osseo integration technique","volume":"44","author":"Eriksson","year":"1986","journal-title":"J\u00a0Oral Maxixofac Surg"},{"key":"10.1016\/j.wneu.2017.11.172_bib9","doi-asserted-by":"crossref","first-page":"261","DOI":"10.3109\/02844318409052849","article-title":"Assessment of bone viability after heat trauma. A histological, histochemical and vital microscopic study in the rabbit","volume":"18","author":"Eriksson","year":"1984","journal-title":"Scand J Plast Reconstr Surg"},{"key":"10.1016\/j.wneu.2017.11.172_bib10","doi-asserted-by":"crossref","first-page":"1510","DOI":"10.1016\/j.medengphy.2012.03.002","article-title":"An experimental investigation on the thermal exposure during bone drilling","volume":"34","author":"Lee","year":"2012","journal-title":"Med Eng Phys"},{"key":"10.1016\/j.wneu.2017.11.172_bib11","doi-asserted-by":"crossref","first-page":"463","DOI":"10.1002\/jor.23044","article-title":"Heat accumulation during sequential cortical bone drilling","volume":"34","author":"Palmisano","year":"2016","journal-title":"J\u00a0Orthop Res"},{"key":"10.1016\/j.wneu.2017.11.172_bib12","doi-asserted-by":"crossref","first-page":"313","DOI":"10.1016\/j.clinbiomech.2011.10.010","article-title":"Cortical bone drilling and thermal osteonecrosis","volume":"27","author":"Augustin","year":"2012","journal-title":"Clin Biomech"},{"key":"10.1016\/j.wneu.2017.11.172_bib13","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1007\/s00402-007-0427-3","article-title":"Thermal osteonecrosis and bone drilling parameters revisited","volume":"128","author":"Augustin","year":"2008","journal-title":"Arch Orthop Trauma Surg"},{"key":"10.1016\/j.wneu.2017.11.172_bib14","doi-asserted-by":"crossref","first-page":"627","DOI":"10.3171\/2013.2.SPINE12879","article-title":"Safety of spinal decompression using an ultrasonic bone curette compared with a high-speed drill: outcomes in 337 patients","volume":"18","author":"Bydon","year":"2013","journal-title":"J\u00a0Neurosurg Spine"},{"key":"10.1016\/j.wneu.2017.11.172_bib15","doi-asserted-by":"crossref","first-page":"451","DOI":"10.1016\/j.ijom.2010.11.013","article-title":"Piezosurgery in oral and maxillofacial surgery","volume":"40","author":"Palikova","year":"2011","journal-title":"Int J Oral Maxillofac Surg"},{"key":"10.1016\/j.wneu.2017.11.172_bib16","doi-asserted-by":"crossref","first-page":"334","DOI":"10.1097\/01.id.0000247859.86693.ef","article-title":"Piezosurgery: basics and possibilities","volume":"15","author":"Schlee","year":"2006","journal-title":"Implant Dent"},{"key":"10.1016\/j.wneu.2017.11.172_bib17","doi-asserted-by":"crossref","first-page":"1385","DOI":"10.1111\/j.1600-0501.2010.02121.x","article-title":"Cutting chracteristics of ultrasonic surgical instruments","volume":"22","author":"Parmar","year":"2011","journal-title":"Clin Oral Impl Res"},{"key":"10.1016\/j.wneu.2017.11.172_bib18","doi-asserted-by":"crossref","first-page":"679","DOI":"10.1016\/j.bjoms.2015.05.004","article-title":"Heat generation and drill wera during dental implant site preparation: a systematic review","volume":"53","author":"M\u00f6hlhenrich","year":"2015","journal-title":"Br J Oral Maxillofac Surg"},{"key":"10.1016\/j.wneu.2017.11.172_bib19","first-page":"1","article-title":"Heat and bone tissue. An experimental investigation of the thermal properties of bone and threshold levels for thermal injury","volume":"9","author":"Lundskog","year":"1972","journal-title":"Scand J Plast Reconstr Surg"},{"key":"10.1016\/j.wneu.2017.11.172_bib20","doi-asserted-by":"crossref","first-page":"2321","DOI":"10.1007\/s00701-013-1867-x","article-title":"Bone temperature elevation by drilling friction and neurological outcome in the cervical spino-laminoplasty","volume":"155","author":"Yamamoto","year":"2013","journal-title":"Acta Neurochir (Wien)"},{"key":"10.1016\/j.wneu.2017.11.172_bib21","doi-asserted-by":"crossref","first-page":"1541","DOI":"10.1302\/0301-620X.91B11.22196","article-title":"Potential risk of thermal damage to cervical nerve roots by a high-speed drill","volume":"91","author":"Hosono","year":"2009","journal-title":"J\u00a0Bone Joint Surg Br"},{"key":"10.1016\/j.wneu.2017.11.172_bib22","doi-asserted-by":"crossref","first-page":"420","DOI":"10.3171\/2013.7.SPINE13144","article-title":"The use of cooled saline during bone drilling to reduce the incidence of upper-limb palsy after cervical laminoplasty: clinical article","volume":"19","author":"Takenaka","year":"2013","journal-title":"J\u00a0Neurosurg Spine"},{"key":"10.1016\/j.wneu.2017.11.172_bib23","doi-asserted-by":"crossref","first-page":"1072","DOI":"10.1016\/j.jcms.2015.05.018","article-title":"Intraosseous heat generation during sonic, ultrasonic and conventional osteotomy","volume":"43","author":"Rashad","year":"2015","journal-title":"J\u00a0Craniomaxillofac Surg"},{"key":"10.1016\/j.wneu.2017.11.172_bib24","doi-asserted-by":"crossref","first-page":"234","DOI":"10.1016\/j.medengphy.2010.10.003","article-title":"Experimental investigations of forces and toque in conventional and ultrasonic-assited drilling of cortical bone","volume":"33","author":"Alam","year":"2011","journal-title":"Med Eng Phys"},{"key":"10.1016\/j.wneu.2017.11.172_bib25","doi-asserted-by":"crossref","first-page":"1962","DOI":"10.1016\/j.wneu.2015.08.043","article-title":"The reliability of the ultrasonic bone scalpel in cervical spondylotic myelopathy: a comparative study of 46 patients","volume":"84","author":"Resid Onen","year":"2015","journal-title":"World Neurosurg"},{"key":"10.1016\/j.wneu.2017.11.172_bib26","doi-asserted-by":"crossref","first-page":"723","DOI":"10.3109\/02656739309032059","article-title":"Ultrastructural changes in the rat sciatic nerve after local hyperthermia","volume":"9","author":"Hoogeveen","year":"1993","journal-title":"Int J Hyperthermia"},{"key":"10.1016\/j.wneu.2017.11.172_bib27","doi-asserted-by":"crossref","first-page":"344","DOI":"10.1016\/0022-4804(87)90091-6","article-title":"Sciatic nerve function following hindlimb thermal injury","volume":"43","author":"Monafo","year":"1987","journal-title":"J\u00a0Surg Res"},{"key":"10.1016\/j.wneu.2017.11.172_bib28","doi-asserted-by":"crossref","first-page":"1215","DOI":"10.1097\/00007632-198911000-00014","article-title":"An experimental study of spinal cord evoked potentials and histologic changes following spinal cord heating","volume":"14","author":"Uchiyama","year":"1989","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.1016\/j.wneu.2017.11.172_bib29","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1007\/BF02200140","article-title":"The European Spine Society AcroMed Prize 1994. Acute thermal nerve root injury","volume":"3","author":"Konno","year":"1994","journal-title":"Eur Spine J"}],"container-title":["World Neurosurgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1878875017321058?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1878875017321058?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2022,8,10]],"date-time":"2022-08-10T03:44:38Z","timestamp":1660103078000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1878875017321058"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,3]]},"references-count":29,"alternative-id":["S1878875017321058"],"URL":"https:\/\/doi.org\/10.1016\/j.wneu.2017.11.172","relation":{},"ISSN":["1878-8750"],"issn-type":[{"value":"1878-8750","type":"print"}],"subject":[],"published":{"date-parts":[[2018,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Heat Generation During Bony Decompression of Lumbar Spinal Stenosis Using a High-Speed Diamond Drill with or without Automated Irrigation and an Ultrasonic Bone-Cutting Knife: A Single-Blinded Prospective Randomized Controlled Study","name":"articletitle","label":"Article Title"},{"value":"World Neurosurgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.wneu.2017.11.172","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2017 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}