{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,28]],"date-time":"2026-07-28T19:38:38Z","timestamp":1785267518783,"version":"3.55.0"},"reference-count":33,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2018,6,1]],"date-time":"2018-06-01T00:00:00Z","timestamp":1527811200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","worldneurosurgery.org","clinicalkey.es","clinicalkey.fr","clinicalkey.com.au","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["World Neurosurgery"],"published-print":{"date-parts":[[2018,6]]},"DOI":"10.1016\/j.wneu.2018.02.192","type":"journal-article","created":{"date-parts":[[2018,3,10]],"date-time":"2018-03-10T19:42:41Z","timestamp":1520710961000},"page":"e403-e411","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":15,"special_numbering":"C","title":["Comparison of Clinical and Radiographic Results Between Posterior Pedicle-Based Dynamic Stabilization and Posterior Lumbar Intervertebral Fusion for Lumbar Degenerative Disease: A 2-Year Retrospective Study"],"prefix":"10.1016","volume":"114","author":[{"given":"Haiying","family":"Wang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bing","family":"Lv","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"suppl 2","key":"10.1016\/j.wneu.2018.02.192_bib1","doi-asserted-by":"crossref","first-page":"S136","DOI":"10.1007\/s00586-006-1070-3","article-title":"Chapter 2. European guidelines for prevention in low back pain: 2004","volume":"15","author":"Burton","year":"2006","journal-title":"Eur Spine J"},{"key":"10.1016\/j.wneu.2018.02.192_bib2","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1097\/01.BRS.0000105527.13866.0F","article-title":"Estimates and patterns of direct health care expenditures among individuals with back pain in the United States","volume":"29","author":"Luo","year":"2004","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.1016\/j.wneu.2018.02.192_bib3","doi-asserted-by":"crossref","first-page":"581","DOI":"10.1016\/S0140-6736(99)01312-4","article-title":"Epidemiological features of chronic low back pain","volume":"354","author":"Andersson","year":"1999","journal-title":"Lancet"},{"key":"10.1016\/j.wneu.2018.02.192_bib4","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1007\/978-3-319-01830-0_6","article-title":"Pedicle-based non-fusion stabilization devices: a critical review and appraisal of current evidence","volume":"41","author":"Obernauer","year":"2014","journal-title":"Adv Tech Stand Neurosurg"},{"key":"10.1016\/j.wneu.2018.02.192_bib5","doi-asserted-by":"crossref","first-page":"151","DOI":"10.3171\/2011.3.SPINE0969","article-title":"Nonfusion stabilization of the degenerative lumbar spine","volume":"15","author":"Maleci","year":"2011","journal-title":"J\u00a0Neurosurg Spine"},{"key":"10.1016\/j.wneu.2018.02.192_bib6","doi-asserted-by":"crossref","first-page":"2312","DOI":"10.1097\/01.brs.0000182315.88558.9c","article-title":"Surgery for degenerative lumbar spondylosis: updated Cochrane Review","volume":"30","author":"Gibson","year":"2005","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.1016\/j.wneu.2018.02.192_bib7","doi-asserted-by":"crossref","first-page":"455","DOI":"10.1097\/01.BRS.0000090825.94611.28","article-title":"Critical analysis of trends in fusion for degenerative disc disease over the past 20 years: influence of technique on fusion rate and clinical outcome","volume":"29","author":"Bono","year":"2004","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.1016\/j.wneu.2018.02.192_bib8","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1016\/j.clineuro.2013.11.016","article-title":"Unilateral versus bilateral pedicle screw fixation in lumbar interbody fusion: a meta-analysis of complication and fusion rate","volume":"117","author":"Yuan","year":"2014","journal-title":"Clin Neurol Neurosurg"},{"key":"10.1016\/j.wneu.2018.02.192_bib9","doi-asserted-by":"crossref","first-page":"314","DOI":"10.1007\/s005860000239","article-title":"Correlation between sagittal plane changes and adjacent segment degeneration following lumbar spine fusion","volume":"10","author":"Kumar","year":"2001","journal-title":"Eur Spine J"},{"key":"10.1016\/j.wneu.2018.02.192_bib10","doi-asserted-by":"crossref","first-page":"1535","DOI":"10.1097\/01.BRS.0000131417.93637.9D","article-title":"Risk factors for adjacent segment degeneration after PLIF","volume":"29","author":"Okuda","year":"2004","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.1016\/j.wneu.2018.02.192_bib11","doi-asserted-by":"crossref","first-page":"1951","DOI":"10.1007\/s00586-011-1917-0","article-title":"Adjacent segment degeneration after instrumented posterolateral lumbar fusion: a prospective cohort study with a minimum five-year follow-up","volume":"20","author":"Anandjiwala","year":"2011","journal-title":"Eur Spine J"},{"key":"10.1016\/j.wneu.2018.02.192_bib12","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1016\/j.clineuro.2015.06.003","article-title":"Comparison of clinical and radiographic results between isobar posterior dynamic stabilization and posterior lumbar inter-body fusion for lumbar degenerative disease: a four-year retrospective study","volume":"136","author":"Yang","year":"2015","journal-title":"Clin Neurol Neurosurg"},{"key":"10.1016\/j.wneu.2018.02.192_bib13","doi-asserted-by":"crossref","first-page":"E3","DOI":"10.3171\/foc.2007.22.1.3","article-title":"Classification of posterior dynamic stabilization devices","volume":"22","author":"Khoueir","year":"2007","journal-title":"Neurosurg Focus"},{"key":"10.1016\/j.wneu.2018.02.192_bib14","doi-asserted-by":"crossref","first-page":"051007","DOI":"10.1115\/1.4027060","article-title":"A\u00a0computational biomechanical investigation of posterior dynamic instrumentation: combination of dynamic rod and hinged (dynamic) screw","volume":"136","author":"Erbulut","year":"2014","journal-title":"J\u00a0Biomech Eng"},{"key":"10.1016\/j.wneu.2018.02.192_bib15","doi-asserted-by":"crossref","first-page":"629698","DOI":"10.1155\/2012\/629698","article-title":"A\u00a0short history of posterior dynamic stabilization","volume":"2012","author":"Gomleksiz","year":"2012","journal-title":"Adv Orthop"},{"key":"10.1016\/j.wneu.2018.02.192_bib16","doi-asserted-by":"crossref","first-page":"E7","DOI":"10.3171\/2015.10.FOCUS15426","article-title":"Dynamic stabilization using the Dynesys system versus posterior lumbar interbody fusion for the treatment of degenerative lumbar spinal disease: a clinical and radiological outcomes-based meta-analysis","volume":"40","author":"Lee","year":"2016","journal-title":"Neurosurg Focus"},{"key":"10.1016\/j.wneu.2018.02.192_bib17","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1590\/1806-9282.60.02.013","article-title":"Dynamic compared to rigid fixation in lumbar spine: a systematic review","volume":"60","author":"Botelho","year":"2014","journal-title":"Rev Assoc Bras (1992)"},{"key":"10.1016\/j.wneu.2018.02.192_bib18","doi-asserted-by":"crossref","first-page":"375","DOI":"10.1007\/s10143-016-0763-2","article-title":"Clinical and biomechanical researches of polyetheretherketone (PEEK) rods for semi-rigid lumbar fusion: a systematic review","volume":"41","author":"Li","year":"2018","journal-title":"Neurosurg Rev"},{"key":"10.1016\/j.wneu.2018.02.192_bib19","first-page":"495","article-title":"Biomechanical comparison of the K-ROD and Dynesys dynamic spinal fixator systems\u2014a finite element analysis","volume":"23","author":"Lin","year":"2013","journal-title":"Biomed Mater Eng"},{"key":"10.1016\/j.wneu.2018.02.192_bib20","doi-asserted-by":"crossref","first-page":"214","DOI":"10.1097\/WNQ.0000000000000169","article-title":"Clinical outcomes of the Dynamic lumbar pedicle screw-rod stabilization: 2-year follow-up results","volume":"26","author":"Wang","year":"2016","journal-title":"Neurosurg Q"},{"key":"10.1016\/j.wneu.2018.02.192_bib21","doi-asserted-by":"crossref","first-page":"2674","DOI":"10.1097\/BRS.0b013e3181b4aaac","article-title":"Disc height and segmental motion as risk factors for recurrent lumbar disc herniation","volume":"34","author":"Kim","year":"2009","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.1016\/j.wneu.2018.02.192_bib22","doi-asserted-by":"crossref","first-page":"24","DOI":"10.1016\/j.jocn.2016.09.030","article-title":"Evaluation of Coflex interspinous stabilization following decompression compared with decompression and posterior lumbar interbody fusion for the treatment of lumbar degenerative disease: a minimum 5-year follow-up study","volume":"35","author":"Yuan","year":"2017","journal-title":"J\u00a0Clin Neurosci"},{"key":"10.1016\/j.wneu.2018.02.192_bib23","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1016\/j.spinee.2012.11.014","article-title":"Comparison of the biomechanical effect of pedicle-based dynamic stabilization: a study using finite element analysis","volume":"13","author":"Jahng","year":"2013","journal-title":"Spine J"},{"key":"10.1016\/j.wneu.2018.02.192_bib24","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1186\/s13018-015-0231-7","article-title":"Comparison between posterior dynamic stabilization and posterior lumbar interbody fusion in the treatment of degenerative disc disease: a prospective cohort study","volume":"10","author":"Fei","year":"2015","journal-title":"J\u00a0Orthop Surg Res"},{"key":"10.1016\/j.wneu.2018.02.192_bib25","doi-asserted-by":"crossref","first-page":"E831","DOI":"10.1097\/BRS.0000000000000917","article-title":"Adjacent segment disease after posterior lumbar interbody fusion: based on cases with a minimum of 10 years of follow-up","volume":"40","author":"Nakashima","year":"2015","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.1016\/j.wneu.2018.02.192_bib26","doi-asserted-by":"crossref","first-page":"E11","DOI":"10.3171\/foc.2007.22.1.11","article-title":"Flexible rods and the case for dynamic stabilization","volume":"22","author":"Highsmith","year":"2007","journal-title":"Neurosurg Focus"},{"key":"10.1016\/j.wneu.2018.02.192_bib27","first-page":"97","article-title":"Dynesys dynamic stabilization: less good outcome than lumbar fusion at 4-year follow-up","volume":"79","author":"Haddad","year":"2013","journal-title":"Acta Orthop Belg"},{"key":"10.1016\/j.wneu.2018.02.192_bib28","doi-asserted-by":"crossref","first-page":"583","DOI":"10.1007\/s00402-012-1460-4","article-title":"Radiographic and clinical results of posterior dynamic stabilization for the treatment of multisegment degenerative disc disease with a minimum follow-up of 3 years","volume":"132","author":"Yu","year":"2012","journal-title":"Arch Orthop Trauma Surg"},{"key":"10.1016\/j.wneu.2018.02.192_bib29","doi-asserted-by":"crossref","first-page":"S170","DOI":"10.1007\/s00586-002-0438-2","article-title":"The dynamic neutralization system for the spine: a multi-center study of a novel non-fusion system","volume":"11","author":"Stoll","year":"2002","journal-title":"Eur Spine J"},{"key":"10.1016\/j.wneu.2018.02.192_bib30","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1186\/s12891-016-0913-2","article-title":"Non-fusion procedure using PEEK rod systems for lumbar degenerative diseases: clinical experience with a 2-year follow-up","volume":"17","author":"Huang","year":"2016","journal-title":"BMC Musculoskelet Disord"},{"key":"10.1016\/j.wneu.2018.02.192_bib31","doi-asserted-by":"crossref","first-page":"2909","DOI":"10.1097\/BRS.0b013e31818bdca7","article-title":"Disc changes in the bridged and adjacent segments after Dynesys dynamic stabilization system after two years","volume":"33","author":"Kumar","year":"2008","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.1016\/j.wneu.2018.02.192_bib32","doi-asserted-by":"crossref","first-page":"1653","DOI":"10.1016\/j.spinee.2015.03.015","article-title":"In\u00a0vivo dynamic changes of dimensions in the lumbar intervertebral foramen","volume":"15","author":"Zhong","year":"2015","journal-title":"Spine J"},{"key":"10.1016\/j.wneu.2018.02.192_bib33","doi-asserted-by":"crossref","first-page":"1494","DOI":"10.1007\/s00586-009-1081-y","article-title":"Interspinous implants (X Stop, Wallis, Diam) for the treatment of LSS: is there a correlation between radiological parameters and clinical outcome?","volume":"18","author":"Sobottke","year":"2009","journal-title":"Eur Spine J"}],"container-title":["World Neurosurgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1878875018304662?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1878875018304662?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2020,10,29]],"date-time":"2020-10-29T01:39:14Z","timestamp":1603935554000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1878875018304662"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,6]]},"references-count":33,"alternative-id":["S1878875018304662"],"URL":"https:\/\/doi.org\/10.1016\/j.wneu.2018.02.192","relation":{},"ISSN":["1878-8750"],"issn-type":[{"value":"1878-8750","type":"print"}],"subject":[],"published":{"date-parts":[[2018,6]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Comparison of Clinical and Radiographic Results Between Posterior Pedicle-Based Dynamic Stabilization and Posterior Lumbar Intervertebral Fusion for Lumbar Degenerative Disease: A 2-Year Retrospective Study","name":"articletitle","label":"Article Title"},{"value":"World Neurosurgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.wneu.2018.02.192","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2018 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}