{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,11]],"date-time":"2026-09-11T02:34:15Z","timestamp":1789094055550,"version":"build-2803163510"},"reference-count":18,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2018,9,1]],"date-time":"2018-09-01T00:00:00Z","timestamp":1535760000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2018,9,1]],"date-time":"2018-09-01T00:00:00Z","timestamp":1535760000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["World Neurosurgery"],"published-print":{"date-parts":[[2018,9]]},"DOI":"10.1016\/j.wneu.2018.06.115","type":"journal-article","created":{"date-parts":[[2018,6,22]],"date-time":"2018-06-22T14:20:47Z","timestamp":1529677247000},"page":"249-254","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":10,"special_numbering":"C","title":["Spontaneous Regression of an Intraparenchymal Cyst Following Deep Brain Stimulator Electrode Implantation: Case Report and Literature Review"],"prefix":"10.1016","volume":"117","author":[{"given":"Michael D.","family":"Staudt","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Keith W.","family":"MacDougall","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.wneu.2018.06.115_bib1","doi-asserted-by":"crossref","first-page":"248","DOI":"10.1159\/000096499","article-title":"Hardware-related complications of deep brain stimulation: a review of the published literature","volume":"84","author":"Hamani","year":"2006","journal-title":"Stereotac Funct Neurosurg"},{"key":"10.1016\/j.wneu.2018.06.115_bib2","first-page":"1268","article-title":"Long-term hardware-related complications of deep brain stimulation","volume":"50","author":"Oh","year":"2002","journal-title":"Neurosurgery"},{"key":"10.1016\/j.wneu.2018.06.115_bib3","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1159\/000323372","article-title":"Long-term surgical and hardware-related complications of deep brain stimulation","volume":"89","author":"Doshi","year":"2011","journal-title":"Stereotac Funct Neurosurg"},{"key":"10.1016\/j.wneu.2018.06.115_bib4","doi-asserted-by":"crossref","first-page":"338","DOI":"10.1159\/000350021","article-title":"Intraparenchymal cyst development after deep brain stimulator placement","volume":"91","author":"Ramirez-Zamora","year":"2013","journal-title":"Stereotact Funct Neurosurg"},{"key":"10.1016\/j.wneu.2018.06.115_bib5","unstructured":"Sarkar A, Wharen REJ, Utti RJ. Novel cyst formation after deep brain stimulator placement: description of case and treatment. Paper presented at Congress of Neurological Surgeons, September 21-26, 2002; Philadelphia, PA."},{"key":"10.1016\/j.wneu.2018.06.115_bib6","first-page":"2015","article-title":"Deep brain stimulation complicated by bilateral large cystic cavitation around the leads in a patient with Parkinson\u2019s disease","author":"Jagid","year":"2015","journal-title":"BMJ Case Rep"},{"key":"10.1016\/j.wneu.2018.06.115_bib7","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1002\/mdc3.12230","article-title":"Cystic lesions as a rare complication of deep brain stimulation","volume":"3","author":"Sharma","year":"2016","journal-title":"Mov Disord Clin Pract"},{"key":"10.1016\/j.wneu.2018.06.115_bib8","doi-asserted-by":"crossref","first-page":"e223","DOI":"10.1212\/WNL.0000000000003284","article-title":"Teaching NeuroImages: noninfectious cyst as an unusual complication of deep brain stimulation","volume":"87","author":"Gupta","year":"2016","journal-title":"Neurology"},{"key":"10.1016\/j.wneu.2018.06.115_bib9","unstructured":"Morrison P, Richard I. Long term tremor benefit from cyst formation as a complication of DBS surgery in a patient with Parkinson\u2019s disease. Paper presented at: International Parkinson and Movement Disorder Society, June 4-8, 2017; Vancouver, BC."},{"key":"10.1016\/j.wneu.2018.06.115_bib10","doi-asserted-by":"crossref","first-page":"576","DOI":"10.1093\/ons\/opx037","article-title":"Intraparenchymal cysts following deep brain stimulation: variable presentations and clinical courses","volume":"13","author":"Katlowitz","year":"2017","journal-title":"Oper Neurosurg (Hagerstown)"},{"key":"10.1016\/j.wneu.2018.06.115_bib11","first-page":"1175","volume":"Vol. 29","author":"Baxi","year":"2014"},{"key":"10.1016\/j.wneu.2018.06.115_bib12","doi-asserted-by":"crossref","first-page":"1713","DOI":"10.1007\/s00701-017-3252-7","article-title":"Delayed complications of deep brain stimulation: 16-year experience in 249 patients","volume":"159","author":"Fernandez-Pajarin","year":"2017","journal-title":"Acta Neurochir"},{"key":"10.1016\/j.wneu.2018.06.115_bib13","doi-asserted-by":"crossref","first-page":"910","DOI":"10.1016\/j.jocn.2010.11.020","article-title":"Transient, symptomatic, post-operative, non-infectious hypodensity around the deep brain stimulation (DBS) electrode","volume":"18","author":"Deogaonkar","year":"2011","journal-title":"J\u00a0Clin Neurosci"},{"key":"10.1016\/j.wneu.2018.06.115_bib14","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1016\/j.parkreldis.2016.09.007","article-title":"Idiopathic delayed-onset edema surrounding deep brain stimulation leads: insights from a case series and systematic literature review","volume":"32","author":"de Cuba","year":"2016","journal-title":"Parkinsonism Relat Disord"},{"key":"10.1016\/j.wneu.2018.06.115_bib15","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1159\/000457964","article-title":"Cost of deep brain stimulation infection resulting in explantation","volume":"95","author":"Chen","year":"2017","journal-title":"Stereotac Funct Neurosurg"},{"key":"10.1016\/j.wneu.2018.06.115_bib16","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1186\/s13256-017-1275-6","article-title":"Acute symptomatic peri-lead edema 33 hours after deep brain stimulation surgery: a case report","volume":"11","author":"Schoen","year":"2017","journal-title":"J\u00a0Med Case Rep"},{"key":"10.1016\/j.wneu.2018.06.115_bib17","doi-asserted-by":"crossref","first-page":"1199","DOI":"10.1007\/s00701-005-0603-6","article-title":"Reversible CSF cyst related to a functioning ventriculo-peritoneal shunt","volume":"147","author":"Vajramani","year":"2005","journal-title":"Acta Neurochir"},{"key":"10.1016\/j.wneu.2018.06.115_bib18","doi-asserted-by":"crossref","first-page":"658","DOI":"10.1016\/j.jocn.2009.07.122","article-title":"Reversible cerebrospinal fluid edema and porencephalic cyst, a rare complication of ventricular catheter","volume":"17","author":"Ozeki","year":"2010","journal-title":"J\u00a0Clin Neurosci"}],"container-title":["World Neurosurgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1878875018313317?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1878875018313317?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T08:22:10Z","timestamp":1761812530000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1878875018313317"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,9]]},"references-count":18,"alternative-id":["S1878875018313317"],"URL":"https:\/\/doi.org\/10.1016\/j.wneu.2018.06.115","relation":{},"ISSN":["1878-8750"],"issn-type":[{"value":"1878-8750","type":"print"}],"subject":[],"published":{"date-parts":[[2018,9]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Spontaneous Regression of an Intraparenchymal Cyst Following Deep Brain Stimulator Electrode Implantation: Case Report and Literature Review","name":"articletitle","label":"Article Title"},{"value":"World Neurosurgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.wneu.2018.06.115","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2018 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}