{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,21]],"date-time":"2026-03-21T15:10:39Z","timestamp":1774105839523,"version":"3.50.1"},"reference-count":13,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2019,10,1]],"date-time":"2019-10-01T00:00:00Z","timestamp":1569888000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2019,10,1]],"date-time":"2019-10-01T00:00:00Z","timestamp":1569888000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["World Neurosurgery"],"published-print":{"date-parts":[[2019,10]]},"DOI":"10.1016\/j.wneu.2019.06.095","type":"journal-article","created":{"date-parts":[[2019,6,28]],"date-time":"2019-06-28T12:19:45Z","timestamp":1561724385000},"page":"e393-e399","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":6,"special_numbering":"C","title":["Unexpectedly Smaller Artifacts of 3.0-T Magnetic Resonance Imaging than 1.5 T: Recommendation of 3.0-T Scanners for Patients with Magnet-Resistant Adjustable Ventriculoperitoneal Shunt Devices"],"prefix":"10.1016","volume":"130","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0107-6598","authenticated-orcid":false,"given":"Yuki","family":"Amano","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1977-4893","authenticated-orcid":false,"given":"Naoto","family":"Kuroda","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daiki","family":"Uchida","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuya","family":"Sakakura","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4241-3028","authenticated-orcid":false,"given":"Hirokazu","family":"Nakatogawa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Naoto","family":"Ando","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Teiji","family":"Nakayama","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Haruhiko","family":"Sato","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takayuki","family":"Masui","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tetsuro","family":"Sameshima","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tokutaro","family":"Tanaka","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.wneu.2019.06.095_bib1","first-page":"74","article-title":"Adjustable shunt valve-induced magnetic resonance imaging artifact: a comparative study","volume":"113","author":"Toma","year":"2010","journal-title":"J\u00a0Neurosurg"},{"key":"10.1016\/j.wneu.2019.06.095_bib2","doi-asserted-by":"crossref","first-page":"463","DOI":"10.7887\/jcns.27.463","article-title":"Comparison of programmable ventriculoperitoneal shunt artifacts between 3.0 and 1.5 T MR scanner: a proGAV2.0 device (Aesculap) study using General Electric scanner","volume":"27","author":"Amano","year":"2018","journal-title":"Jpn J Neurosurg (Tokyo)"},{"key":"10.1016\/j.wneu.2019.06.095_bib3","first-page":"1","article-title":"Setting pressure can change the size and shape of MRI artifacts caused by adjustable shunt valves: a study of the 4 newest models","author":"Uchida","year":"2018","journal-title":"J Neurosurg"},{"key":"10.1016\/j.wneu.2019.06.095_bib4","doi-asserted-by":"crossref","first-page":"523","DOI":"10.7887\/jcns.26.523","article-title":"Comparing artifacts of 3T MRI between the difference of programmable CSF shunt valve pressures","volume":"26","author":"Uchida","year":"2017","journal-title":"Jpn J Neurosurg (Tokyo)"},{"key":"10.1016\/j.wneu.2019.06.095_bib5","doi-asserted-by":"crossref","first-page":"E1","DOI":"10.3171\/foc.2001.11.2.2","article-title":"History of hydrocephalus and its treatments","volume":"11","author":"Lifshutz","year":"2001","journal-title":"Neurosurg Focus"},{"key":"10.1016\/j.wneu.2019.06.095_bib6","first-page":"471","article-title":"Clinical experience with the use of a shunt with an adjustable valve in children with hydrocephalus","volume":"98","author":"Zemack","year":"2003","journal-title":"J\u00a0Neurosurg"},{"key":"10.1016\/j.wneu.2019.06.095_bib7","doi-asserted-by":"crossref","first-page":"274","DOI":"10.2176\/nmc.ra.2015-0282","article-title":"Shunt devices for the treatment of adult hydrocephalus: recent progress and characteristics","volume":"56","author":"Miyake","year":"2016","journal-title":"Neurol Med Chir (Tokyo)"},{"key":"10.1016\/j.wneu.2019.06.095_bib8","doi-asserted-by":"crossref","first-page":"81","DOI":"10.4103\/2152-7806.99171","article-title":"3T magnetic resonance imaging testing of externally programmable shunt valves","volume":"3","author":"Zabramski","year":"2012","journal-title":"Surg Neurol Int"},{"key":"10.1016\/j.wneu.2019.06.095_bib9","doi-asserted-by":"crossref","first-page":"202","DOI":"10.2214\/AJR.10.5915","article-title":"Assessment of MRI issues for a 3-T \"immune\" programmable CSF shunt valve","volume":"197","author":"Shellock","year":"2011","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.wneu.2019.06.095_bib10","doi-asserted-by":"crossref","first-page":"395","DOI":"10.2176\/nmc.45.395","article-title":"Quantitative analysis of magnetic resonance imaging susceptibility artifacts caused by neurosurgical biomaterials: comparison of 0.5, 1.5, and 3.0 Tesla magnetic fields","volume":"45","author":"Matsuura","year":"2005","journal-title":"Neurol Med Chir (Tokyo)"},{"key":"10.1016\/j.wneu.2019.06.095_bib11","doi-asserted-by":"crossref","first-page":"534","DOI":"10.6009\/jjrt.2014_JSRT_70.6.534","article-title":"[Image distortion and artifacts caused by the use of a titanium aneurism clip in 1.5 tesla- and 3 tesla-magnetic resonance imaging: effect on 60cobalt stereotactic radiosurgery treatment planning]","volume":"70","author":"Nakazawa","year":"2014","journal-title":"Nihon Hoshasen Gijutsu Gakkai Zasshi"},{"key":"10.1016\/j.wneu.2019.06.095_bib12","doi-asserted-by":"crossref","first-page":"547","DOI":"10.2214\/AJR.11.7364","article-title":"Metal-induced artifacts in MRI","volume":"197","author":"Hargreaves","year":"2011","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.wneu.2019.06.095_bib13","doi-asserted-by":"crossref","first-page":"958","DOI":"10.1097\/00004728-200011000-00024","article-title":"Quantification and minimization of magnetic susceptibility artifacts on GRE images","volume":"24","author":"Port","year":"2000","journal-title":"J\u00a0Comput Assist Tomogr"}],"container-title":["World Neurosurgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S187887501931647X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S187887501931647X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T08:35:28Z","timestamp":1761813328000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S187887501931647X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,10]]},"references-count":13,"alternative-id":["S187887501931647X"],"URL":"https:\/\/doi.org\/10.1016\/j.wneu.2019.06.095","relation":{},"ISSN":["1878-8750"],"issn-type":[{"value":"1878-8750","type":"print"}],"subject":[],"published":{"date-parts":[[2019,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Unexpectedly Smaller Artifacts of 3.0-T Magnetic Resonance Imaging than 1.5 T: Recommendation of 3.0-T Scanners for Patients with Magnet-Resistant Adjustable Ventriculoperitoneal Shunt Devices","name":"articletitle","label":"Article Title"},{"value":"World Neurosurgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.wneu.2019.06.095","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2019 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}