{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,16]],"date-time":"2026-10-16T00:15:41Z","timestamp":1792109741181,"version":"4.4.0"},"reference-count":31,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2022,7,1]],"date-time":"2022-07-01T00:00:00Z","timestamp":1656633600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2022,7,1]],"date-time":"2022-07-01T00:00:00Z","timestamp":1656633600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2022,7,1]],"date-time":"2022-07-01T00:00:00Z","timestamp":1656633600000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-017"},{"start":{"date-parts":[[2022,7,1]],"date-time":"2022-07-01T00:00:00Z","timestamp":1656633600000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"},{"start":{"date-parts":[[2022,7,1]],"date-time":"2022-07-01T00:00:00Z","timestamp":1656633600000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-012"},{"start":{"date-parts":[[2022,7,1]],"date-time":"2022-07-01T00:00:00Z","timestamp":1656633600000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2022,7,1]],"date-time":"2022-07-01T00:00:00Z","timestamp":1656633600000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-004"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["World Neurosurgery"],"published-print":{"date-parts":[[2022,7]]},"DOI":"10.1016\/j.wneu.2022.03.137","type":"journal-article","created":{"date-parts":[[2022,4,4]],"date-time":"2022-04-04T20:55:12Z","timestamp":1649105712000},"page":"e377-e383","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":5,"special_numbering":"C","title":["The Feasibility of Creating Image-Based Patient-Specific Drill Guides for the Atlantoaxial Instabilities Using Open-Source CAD Software and Desktop 3D Printers"],"prefix":"10.1016","volume":"163","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2952-605X","authenticated-orcid":false,"given":"Azad","family":"Malikov","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ahmet Eren","family":"Secen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Denizhan","family":"Divanlioglu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Goksal","family":"Gunerhan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ozgur","family":"Ocal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ugur Kemal","family":"Gunduz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.wneu.2022.03.137_bib1","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1007\/s00586-009-1181-8","article-title":"Evaluation of anatomic landmarks and safe zones for screw placement in the atlas via the posterior arch","volume":"19","author":"Gebauer","year":"2010","journal-title":"Eur Spine J"},{"key":"10.1016\/j.wneu.2022.03.137_bib2","doi-asserted-by":"crossref","first-page":"678","DOI":"10.1227\/01.NEU.0000367632.45384.5A","article-title":"Direct posterior reduction and fixation for the treatment of basilar invagination with atlantoaxial dislocation","volume":"66","author":"Jian","year":"2010","journal-title":"Neurosurgery"},{"key":"10.1016\/j.wneu.2022.03.137_bib3","doi-asserted-by":"crossref","first-page":"37","DOI":"10.3340\/jkns.2010.48.1.37","article-title":"Surgical treatment of craniovertebral junction instability\u202f: clinical outcomes and effectiveness in personal experience","volume":"48","author":"Song","year":"2010","journal-title":"J\u00a0Korean Neurosurg Soc"},{"key":"10.1016\/j.wneu.2022.03.137_bib4","doi-asserted-by":"crossref","first-page":"476","DOI":"10.1016\/j.spinee.2012.06.010","article-title":"Routine insertion of the lateral mass screw via the posterior arch for C1 fixation: feasibility and related complications","volume":"12","author":"Yeom","year":"2012","journal-title":"Spine J"},{"key":"10.1016\/j.wneu.2022.03.137_bib5","doi-asserted-by":"crossref","first-page":"410","DOI":"10.1302\/0301-620X.75B3.8496209","article-title":"Vertebral artery injury during anterior decompression of the cervical spine. A retrospective Rev ten patients","volume":"75","author":"Smith","year":"1993","journal-title":"J\u00a0Bone Joint Surg Br"},{"key":"10.1016\/j.wneu.2022.03.137_bib6","first-page":"205","article-title":"Clinical application and Efficacy analysis of 3D navigation Module in the treatment of atlantoaxial instability","volume":"2","author":"Bo-kang","year":"2018","journal-title":"Clin Surg Res Commun"},{"key":"10.1016\/j.wneu.2022.03.137_bib7","doi-asserted-by":"crossref","first-page":"138","DOI":"10.4103\/2542-4157.219374","article-title":"Efficacy and safety of a digital navigation template combined with cervical pedicle screw implantation: study protocol for a prospective, single-center, self-controlled, clinical trial","volume":"2","author":"Wei","year":"2017","journal-title":"Clinical Trials Orthop Disorders"},{"key":"10.1016\/j.wneu.2022.03.137_bib8","doi-asserted-by":"crossref","first-page":"E193","DOI":"10.1097\/BSD.0000000000000813","article-title":"Accuracy and safety in screw placement in the high cervical spine: retrospective analysis of O-arm-based navigation-assisted C1 lateral mass and C2 pedicle screws","volume":"32","author":"Hur","year":"2019","journal-title":"Clin Spine Surg"},{"key":"10.1016\/j.wneu.2022.03.137_bib9","doi-asserted-by":"crossref","first-page":"113","DOI":"10.3171\/2012.5.SPINE11399","article-title":"Pedicle screw navigation: a systematic review and meta-analysis of perforation risk for computer-navigated versus freehand insertion","volume":"17","author":"Shin","year":"2012","journal-title":"J\u00a0Neurosurg Spine"},{"key":"10.1016\/j.wneu.2022.03.137_bib10","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1016\/j.wneu.2012.03.011","article-title":"Worldwide survey on the use of navigation in spine surgery","volume":"79","author":"H\u00e4rtl","year":"2013","journal-title":"World Neurosurg"},{"key":"10.1016\/j.wneu.2022.03.137_bib11","doi-asserted-by":"crossref","first-page":"827","DOI":"10.1007\/s00264-015-2813-8","article-title":"A novel navigation template for fixation of acetabular posterior column fractures with antegrade lag screws: design and application","volume":"40","author":"Chen","year":"2016","journal-title":"Int Orthop"},{"key":"10.1016\/j.wneu.2022.03.137_bib12","first-page":"214","article-title":"Application of navigation template to fixation of sacral fracture using three-dimensional reconstruction and reverse engineering technique","volume":"12","author":"Zhang","year":"2009","journal-title":"Chin J Traumatol"},{"key":"10.1016\/j.wneu.2022.03.137_bib13","doi-asserted-by":"crossref","first-page":"e5557","DOI":"10.1097\/MD.0000000000005557","article-title":"Application of a 3-dimensional printed navigation template in Bernese periacetabular osteotomies: a cadaveric study","volume":"95","author":"Zhou","year":"2016","journal-title":"Medicine (Baltimore)"},{"key":"10.1016\/j.wneu.2022.03.137_bib14","doi-asserted-by":"crossref","first-page":"298","DOI":"10.1002\/rcs.1439","article-title":"An optimal design for patient-specific templates for pedicle spine screws placement","volume":"9","author":"Ferrari","year":"2013","journal-title":"Int J Med Robot"},{"key":"10.1016\/j.wneu.2022.03.137_bib15","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1007\/s10439-013-0890-7","article-title":"Improved accuracy with 3D planning and patient-specific instruments during simulated pelvic bone tumor surgery","volume":"42","author":"Cartiaux","year":"2014","journal-title":"Ann Biomed Eng"},{"key":"10.1016\/j.wneu.2022.03.137_bib16","doi-asserted-by":"crossref","first-page":"1504","DOI":"10.1177\/1071100715595695","article-title":"Utility of 3D Printing for Complex distal Tibial Fractures and Malleolar Avulsion fractures: Technical Tip","volume":"36","author":"Chung","year":"2015","journal-title":"Foot Ankle Int"},{"key":"10.1016\/j.wneu.2022.03.137_bib17","doi-asserted-by":"crossref","first-page":"E341","DOI":"10.1097\/BRS.0000000000000772","article-title":"Safe and accurate midcervical pedicle screw insertion procedure with the patient-specific screw guide template system","volume":"40","author":"Kaneyama","year":"2015","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.1016\/j.wneu.2022.03.137_bib18","doi-asserted-by":"crossref","first-page":"E340","DOI":"10.1097\/BRS.0000000000001807","article-title":"Accurate and simple screw insertion procedure with patient-specific screw guide templates for posterior C1-C2 fixation","volume":"42","author":"Sugawara","year":"2017","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.1016\/j.wneu.2022.03.137_bib19","doi-asserted-by":"crossref","first-page":"4","DOI":"10.4184\/asj.2017.11.1.4","article-title":"A\u00a0novel patient-specific drill guide Template for pedicle screw Insertion into the Subaxial cervical spine Utilizing Stereolithographic Modelling: an in\u00a0Vitro study","volume":"11","author":"Bundoc","year":"2017","journal-title":"Asian Spine J"},{"key":"10.1016\/j.wneu.2022.03.137_bib20","first-page":"20","article-title":"Development of a patient-specific guide for high cervical spine fixation","volume":"54","author":"Nanni","year":"2019","journal-title":"Rev Bras Ortop (Sao Paulo)"},{"key":"10.1016\/j.wneu.2022.03.137_bib21","doi-asserted-by":"crossref","first-page":"2675","DOI":"10.1097\/00007632-200010150-00022","article-title":"Cervical pedicle screws: comparative accuracy of two insertion techniques","volume":"25","author":"Ludwig","year":"2000","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.1016\/j.wneu.2022.03.137_bib22","doi-asserted-by":"crossref","first-page":"1655","DOI":"10.1097\/00007632-200007010-00009","article-title":"Placement of pedicle screws in the human cadaveric cervical spine: comparative accuracy of three techniques","volume":"25","author":"Ludwig","year":"2000","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.1016\/j.wneu.2022.03.137_bib23","doi-asserted-by":"crossref","first-page":"231","DOI":"10.3171\/2014.3.SPINE13730","article-title":"A novel screw guiding method with a screw guide template system for posterior C-2 fixation: clinical article","volume":"21","author":"Kaneyama","year":"2014","journal-title":"J\u00a0Neurosurg Spine"},{"key":"10.1016\/j.wneu.2022.03.137_bib24","doi-asserted-by":"crossref","first-page":"e13769","DOI":"10.1097\/MD.0000000000013769","article-title":"The effectiveness and safety of 3-dimensional printed composite guide plate for atlantoaxial pedicle screw: a retrospective study","volume":"98","author":"Wang","year":"2019","journal-title":"Medicine"},{"key":"10.1016\/j.wneu.2022.03.137_bib25","first-page":"231","article-title":"Application of 3D printing in orthopedics of scoliosis","author":"LI","year":"2016","journal-title":"Acad J Second Military Med Uni"},{"key":"10.1016\/j.wneu.2022.03.137_bib26","doi-asserted-by":"crossref","first-page":"488","DOI":"10.1007\/s001130170111","article-title":"Development and validation of the Visual Analogue Scale (VAS) spine score","volume":"104","author":"Knop","year":"2011","journal-title":"Unfallchirurg"},{"key":"10.1016\/j.wneu.2022.03.137_bib27","doi-asserted-by":"crossref","first-page":"240","DOI":"10.3109\/10929088.2011.605173","article-title":"Efficacy and accuracy of a novel rapid prototyping drill template for cervical pedicle screw placement","volume":"16","author":"Lu","year":"2011","journal-title":"Computer Aided Surgery"},{"key":"10.1016\/j.wneu.2022.03.137_bib28","doi-asserted-by":"crossref","first-page":"1983","DOI":"10.1097\/BRS.0b013e31825ab547","article-title":"Development of a new technique for pedicle screw and Magerl screw insertion using a 3-dimensional image guide","volume":"37","author":"Kawaguchi","year":"2012","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.1016\/j.wneu.2022.03.137_bib29","doi-asserted-by":"crossref","first-page":"e0214460","DOI":"10.1371\/journal.pone.0214460","article-title":"Design and basic research on accuracy of a novel individualized three-dimensional printed navigation template in atlantoaxial pedicle screw placement","volume":"14","author":"Chen","year":"2019","journal-title":"PLoS One"},{"key":"10.1016\/j.wneu.2022.03.137_bib30","doi-asserted-by":"crossref","first-page":"1483","DOI":"10.1007\/s00402-016-2530-9","article-title":"Accuracy assessment of atlantoaxial pedicle screws assisted by a novel drill guide template","volume":"136","author":"Jiang","year":"2016","journal-title":"Arch Orthop Trauma Surg"},{"key":"10.1016\/j.wneu.2022.03.137_bib31","doi-asserted-by":"crossref","first-page":"297","DOI":"10.1097\/00005131-200205000-00002","article-title":"Iatrogenic nerve injury in acetabular fracture surgery: a comparison of monitored and unmonitored procedures","volume":"16","author":"Haidukewych","year":"2002","journal-title":"J\u00a0Orthop Trauma"}],"container-title":["World Neurosurgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1878875022004326?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1878875022004326?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T09:11:20Z","timestamp":1761815480000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1878875022004326"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,7]]},"references-count":31,"alternative-id":["S1878875022004326"],"URL":"https:\/\/doi.org\/10.1016\/j.wneu.2022.03.137","relation":{},"ISSN":["1878-8750"],"issn-type":[{"value":"1878-8750","type":"print"}],"subject":[],"published":{"date-parts":[[2022,7]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"The Feasibility of Creating Image-Based Patient-Specific Drill Guides for the Atlantoaxial Instabilities Using Open-Source CAD Software and Desktop 3D Printers","name":"articletitle","label":"Article Title"},{"value":"World Neurosurgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.wneu.2022.03.137","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2022 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}