{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,24]],"date-time":"2026-07-24T22:48:36Z","timestamp":1784933316901,"version":"3.55.0"},"reference-count":25,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2023,7,1]],"date-time":"2023-07-01T00:00:00Z","timestamp":1688169600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2023,7,1]],"date-time":"2023-07-01T00:00:00Z","timestamp":1688169600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2023,3,22]],"date-time":"2023-03-22T00:00:00Z","timestamp":1679443200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["World Neurosurgery"],"published-print":{"date-parts":[[2023,7]]},"DOI":"10.1016\/j.wneu.2023.03.062","type":"journal-article","created":{"date-parts":[[2023,3,24]],"date-time":"2023-03-24T13:10:27Z","timestamp":1679663427000},"page":"e254-e263","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":4,"special_numbering":"C","title":["Intraoperative Cone-Beam Computed Tomography Assessment of Spinal Pedicle Screws Placement Precision Is in Full Agreement with Postoperative Computed Tomography Assessment"],"prefix":"10.1016","volume":"175","author":[{"given":"Hiroki","family":"Ohashi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9026-7627","authenticated-orcid":false,"given":"Daichi","family":"Kawamura","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Keisuke","family":"Hatano","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"So","family":"Ohashi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Satoru","family":"Tochigi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Akira","family":"Isoshima","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroyasu","family":"Nagashima","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2322-3405","authenticated-orcid":false,"given":"Katharina","family":"Otani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6105-0480","authenticated-orcid":false,"given":"Kostadin","family":"Karagiozov","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Satoshi","family":"Tani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3490-385X","authenticated-orcid":false,"given":"Yuichi","family":"Murayama","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.wneu.2023.03.062_bib1","doi-asserted-by":"crossref","first-page":"231","DOI":"10.5435\/JAAOS-D-15-00638","article-title":"Percutaneous pedicle screw stabilization: surgical technique, fracture reduction, and review of current spine trauma applications","volume":"26","author":"Alander","year":"2018","journal-title":"J\u00a0Am Acad Orthop Surg"},{"key":"10.1016\/j.wneu.2023.03.062_bib2","first-page":"303","article-title":"Percutaneous pedicle screw fixation technique in the thoracic and lumbar spine-Tips and Tricks","volume":"28","author":"Gazzeri","year":"2016","journal-title":"Surg Technol Int"},{"key":"10.1016\/j.wneu.2023.03.062_bib3","doi-asserted-by":"crossref","first-page":"2392","DOI":"10.1097\/01.brs.0000238973.13294.16","article-title":"Comparison of pelvic fixation techniques in neuromuscular spinal deformity correction: Galveston rod versus iliac and lumbosacral screws","volume":"31","author":"Peelle","year":"2006","journal-title":"Spine"},{"key":"10.1016\/j.wneu.2023.03.062_bib4","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1007\/s12306-016-0438-8","article-title":"Pedicle screw insertion techniques: an update and review of the literature","volume":"100","author":"Perna","year":"2016","journal-title":"Musculoskeletal Surg"},{"key":"10.1016\/j.wneu.2023.03.062_bib5","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1016\/j.clineuro.2015.05.016","article-title":"Percutaneous versus open pedicle screw fixation for treatment of thoracolumbar fractures: systematic review and meta-analysis of comparative studies","volume":"135","author":"Phan","year":"2015","journal-title":"Clin Neurol Neurosurg"},{"key":"10.1016\/j.wneu.2023.03.062_bib6","doi-asserted-by":"crossref","first-page":"196","DOI":"10.3171\/2013.11.SPINE13413","article-title":"The accuracy of pedicle screw placement using intraoperative image guidance systems","volume":"20","author":"Mason","year":"2014","journal-title":"J\u00a0Neurosurg Spine"},{"key":"10.1016\/j.wneu.2023.03.062_bib7","doi-asserted-by":"crossref","first-page":"817","DOI":"10.1016\/j.spinee.2009.06.014","article-title":"Accuracy of upper thoracic pedicle screw placement using three-dimensional image guidance","volume":"9","author":"Bledsoe","year":"2009","journal-title":"Spine J"},{"key":"10.1016\/j.wneu.2023.03.062_bib8","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1016\/j.ijsp.2011.11.002","article-title":"Intraoperative 3-dimensional imaging (O-arm) for assessment of pedicle screw position: does it prevent unacceptable screw placement?","volume":"6","author":"Sembrano","year":"2012","journal-title":"Int J Spine Surg"},{"key":"10.1016\/j.wneu.2023.03.062_bib9","doi-asserted-by":"crossref","first-page":"2527","DOI":"10.1097\/01.BRS.0000092341.56793.F1","article-title":"Inter- and intraobserver reliability of computed tomography in assessment of thoracic pedicle screw placement","volume":"28","author":"Rao","year":"2003","journal-title":"Spine"},{"key":"10.1016\/j.wneu.2023.03.062_bib10","doi-asserted-by":"crossref","first-page":"2906","DOI":"10.1007\/s00586-017-5139-y","article-title":"Accuracy of a new intraoperative cone beam CT imaging technique (Artis zeego II) compared to postoperative CT scan for assessment of pedicle screws placement and breaches detection","volume":"26","author":"Cordemans","year":"2017","journal-title":"Eur Spine J"},{"key":"10.1016\/j.wneu.2023.03.062_bib11","doi-asserted-by":"crossref","first-page":"2917","DOI":"10.1007\/s00586-017-5195-3","article-title":"Pedicle screw insertion accuracy in terms of breach and reposition using a new intraoperative cone beam computed tomography imaging technique and evaluation of the factors associated with these parameters of accuracy: a series of 695 screws","volume":"26","author":"Cordemans","year":"2017","journal-title":"Eur Spine J"},{"key":"10.1016\/j.wneu.2023.03.062_bib12","doi-asserted-by":"crossref","first-page":"1427","DOI":"10.1227\/NEU.0b013e31820b4f1c","article-title":"Robotic digital subtraction angiography systems within the hybrid operating room","volume":"68","author":"Murayama","year":"2011","journal-title":"Neurosurgery"},{"key":"10.1016\/j.wneu.2023.03.062_bib13","doi-asserted-by":"crossref","first-page":"2811","DOI":"10.1007\/s00586-017-4968-z","article-title":"Radiation exposure to the patients in thoracic and lumbar spine fusion using a new intraoperative cone-beam computed tomography imaging technique: a preliminary study","volume":"26","author":"Kaminski","year":"2017","journal-title":"Eur Spine J"},{"key":"10.1016\/j.wneu.2023.03.062_bib14","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1097\/RLI.0000000000000519","article-title":"Advanced robotic angiography systems for image guidance during conventional transarterial chemoembolization: impact on radiation dose and image quality","volume":"54","author":"Vogl","year":"2019","journal-title":"Invest Radiol"},{"key":"10.1016\/j.wneu.2023.03.062_bib15","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1097\/00007632-199001000-00004","article-title":"Accuracy of pedicular screw placement in\u00a0vivo","volume":"15","author":"Gertzbein","year":"1990","journal-title":"Spine"},{"issue":"4 Suppl Spine","key":"10.1016\/j.wneu.2023.03.062_bib16","doi-asserted-by":"crossref","first-page":"325","DOI":"10.3171\/spi.2004.100.4.0325","article-title":"Thoracic pedicle screws: postoperative computerized tomography scanning assessment","volume":"100","author":"Heary","year":"2004","journal-title":"J\u00a0Neurosurg"},{"key":"10.1016\/j.wneu.2023.03.062_bib17","series-title":"Handbook of Inter-Rater Reliability","author":"Gwet","year":"2014"},{"key":"10.1016\/j.wneu.2023.03.062_bib18","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1093\/ptj\/85.3.257","article-title":"The kappa statistic in reliability studies: use, interpretation, and sample size requirements","volume":"85","author":"Sim","year":"2005","journal-title":"Phys Ther"},{"key":"10.1016\/j.wneu.2023.03.062_bib19","doi-asserted-by":"crossref","first-page":"159","DOI":"10.2307\/2529310","article-title":"The measurement of observer agreement for categorical data","volume":"33","author":"Landis","year":"1977","journal-title":"Biometrics"},{"key":"10.1016\/j.wneu.2023.03.062_bib20","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1007\/s00586-011-2011-3","article-title":"Accuracy of pedicle screw placement: a systematic review of prospective in\u00a0vivo studies comparing free hand, fluoroscopy guidance and navigation techniques","volume":"21","author":"Gelalis","year":"2012","journal-title":"Eur Spine J"},{"key":"10.1016\/j.wneu.2023.03.062_bib21","doi-asserted-by":"crossref","first-page":"112","DOI":"10.5312\/wjo.v5.i2.112","article-title":"Techniques and accuracy of thoracolumbar pedicle screw placement","volume":"5","author":"Puvanesarajah","year":"2014","journal-title":"World J Orthop"},{"key":"10.1016\/j.wneu.2023.03.062_bib22","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1097\/00007632-199001000-00004","article-title":"Accuracy of pedicular screw placement in\u00a0vivo","volume":"15","author":"Gertzbein","year":"1990","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.1016\/j.wneu.2023.03.062_bib23","doi-asserted-by":"crossref","first-page":"E13","DOI":"10.3171\/2017.3.FOCUS1710","article-title":"Robotic versus fluoroscopy-guided pedicle screw insertion for metastatic spinal disease: a matched-cohort comparison","volume":"42","author":"Solomiichuk","year":"2017","journal-title":"Neurosurg Focus"},{"issue":"4 Suppl Spine","key":"10.1016\/j.wneu.2023.03.062_bib24","doi-asserted-by":"crossref","first-page":"325","DOI":"10.3171\/spi.2004.100.4.0325","article-title":"Thoracic pedicle screws: postoperative computerized tomography scanning assessment","volume":"100","author":"Heary","year":"2004","journal-title":"J\u00a0Neurosurg"},{"key":"10.1016\/j.wneu.2023.03.062_bib25","doi-asserted-by":"crossref","first-page":"112","DOI":"10.5312\/wjo.v5.i2.112","article-title":"Techniques and accuracy of thoracolumbar pedicle screw placement","volume":"5","author":"Puvanesarajah","year":"2014","journal-title":"World J Orthop"}],"container-title":["World Neurosurgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1878875023003856?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1878875023003856?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T09:19:35Z","timestamp":1761815975000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1878875023003856"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,7]]},"references-count":25,"alternative-id":["S1878875023003856"],"URL":"https:\/\/doi.org\/10.1016\/j.wneu.2023.03.062","relation":{},"ISSN":["1878-8750"],"issn-type":[{"value":"1878-8750","type":"print"}],"subject":[],"published":{"date-parts":[[2023,7]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Intraoperative Cone-Beam Computed Tomography Assessment of Spinal Pedicle Screws Placement Precision Is in Full Agreement with Postoperative Computed Tomography Assessment","name":"articletitle","label":"Article Title"},{"value":"World Neurosurgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.wneu.2023.03.062","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2023 The Author(s). Published by Elsevier Inc.","name":"copyright","label":"Copyright"}]}}