{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,10]],"date-time":"2026-10-10T17:44:40Z","timestamp":1791654280021,"version":"4.3.4"},"reference-count":35,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2025,5,1]],"date-time":"2025-05-01T00:00:00Z","timestamp":1746057600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,5,1]],"date-time":"2025-05-01T00:00:00Z","timestamp":1746057600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2025,3,3]],"date-time":"2025-03-03T00:00:00Z","timestamp":1740960000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100007064","name":"NuVasive","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100007064","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.fr","clinicalkey.jp","clinicalkey.es","clinicalkey.com.au","clinicalkey.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["World Neurosurgery"],"published-print":{"date-parts":[[2025,5]]},"DOI":"10.1016\/j.wneu.2025.123878","type":"journal-article","created":{"date-parts":[[2025,3,8]],"date-time":"2025-03-08T23:16:04Z","timestamp":1741475764000},"page":"123878","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":3,"special_numbering":"C","title":["Safety and Feasibility of Transabdominal Muscle Action Potential Monitoring in Lateral Lumbar Surgery"],"prefix":"10.1016","volume":"197","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1331-6413","authenticated-orcid":false,"given":"Kaveh","family":"Khajavi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jim","family":"Youssef","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert K.","family":"Eastlack","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeffrey R.","family":"Balzer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Greg","family":"Niznik","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"William","family":"Smith","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.wneu.2025.123878_bib1","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1007\/s00586-015-3886-1","article-title":"MIS lateral spine surgery: a systematic literature review of complications, outcomes, and economics","volume":"24","author":"Lehmen","year":"2015","journal-title":"Eur Spine J"},{"issue":"Suppl 2","key":"10.1016\/j.wneu.2025.123878_bib2","doi-asserted-by":"crossref","first-page":"S140","DOI":"10.1007\/s00586-007-0416-9","article-title":"History of the development of intraoperative spinal cord monitoring","volume":"16","author":"Tamaki","year":"2007","journal-title":"Eur Spine J"},{"key":"10.1016\/j.wneu.2025.123878_bib3","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1097\/00003086-197306000-00017","article-title":"Functional monitoring of spinal cord activity during spinal surgery","author":"Vauzelle","year":"1973","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.wneu.2025.123878_bib4","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1038\/285227a0","article-title":"Stimulation of the cerebral cortex in the intact human subject","volume":"285","author":"Merton","year":"1980","journal-title":"Nature"},{"key":"10.1016\/j.wneu.2025.123878_bib5","doi-asserted-by":"crossref","first-page":"551","DOI":"10.1227\/00006123-199110000-00011","article-title":"Noninvasive intraoperative monitoring of motor evoked potentials under propofol anesthesia: effects of spinal surgery on the amplitude and latency of motor evoked potentials","volume":"29","author":"Jellinek","year":"1991","journal-title":"Neurosurgery"},{"key":"10.1016\/j.wneu.2025.123878_bib6","doi-asserted-by":"crossref","DOI":"10.1155\/2021\/2684855","article-title":"Transcranial electrical motor evoked potential in predicting positive functional outcome of patients after decompressive spine surgery: review on challenges and recommendations towards objective interpretation","volume":"2021","author":"Jamaludin","year":"2021","journal-title":"Behav Neurol"},{"key":"10.1016\/j.wneu.2025.123878_bib7","doi-asserted-by":"crossref","first-page":"911","DOI":"10.1097\/BRS.0000000000003433","article-title":"Neuroanesthesia guidelines for optimizing transcranial motor evoked potential neuromonitoring during deformity and complex spinal surgery: a delphi consensus study","volume":"45","author":"Walker","year":"2020","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.1016\/j.wneu.2025.123878_bib8","doi-asserted-by":"crossref","first-page":"689","DOI":"10.1007\/s10877-022-00903-4","article-title":"Intraoperative transabdominal MEPs: four case reports","volume":"37","author":"Allison","year":"2023","journal-title":"J Clin Monit Comput"},{"key":"10.1016\/j.wneu.2025.123878_bib9","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1186\/s12871-020-00974-3","article-title":"Retrospective analysis of cases of intraoperative awareness in a large multi-hospital health system reported in the early postoperative period","volume":"20","author":"Deis","year":"2020","journal-title":"BMC Anesthesiol"},{"key":"10.1016\/j.wneu.2025.123878_bib10","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1080\/21646821.2021.1866934","article-title":"Roadmap for motor evoked potential (MEP) monitoring for patients undergoing lumbar and lumbosacral spinal fusion procedures","volume":"61","author":"Wilent","year":"2021","journal-title":"Neurodiagn J"},{"key":"10.1016\/j.wneu.2025.123878_bib11","doi-asserted-by":"crossref","first-page":"439","DOI":"10.4103\/0970-9185.137297","article-title":"Tongue bite injury after use of transcranial electric stimulation motor-evoked potential monitoring","volume":"30","author":"Williams","year":"2014","journal-title":"J Anaesthesiol Clin Pharmacol"},{"key":"10.1016\/j.wneu.2025.123878_bib12","doi-asserted-by":"crossref","first-page":"226","DOI":"10.4236\/ojanes.2012.25052","article-title":"Tongue laceration during neurophysiologic monitoring with motor evoked potentials","volume":"02","author":"Pisklakov","year":"2012","journal-title":"Open J Anesthesiol"},{"key":"10.1016\/j.wneu.2025.123878_bib13","doi-asserted-by":"crossref","first-page":"663","DOI":"10.1213\/ANE.0b013e3182542331","article-title":"The incidence of bite injuries associated with transcranial motor-evoked potential monitoring","volume":"115","author":"Tamkus","year":"2012","journal-title":"Anesth Analg"},{"key":"10.1016\/j.wneu.2025.123878_bib14","doi-asserted-by":"crossref","first-page":"844","DOI":"10.1007\/s00540-018-2562-0","article-title":"Bite injuries caused by transcranial electrical stimulation motor-evoked potentials' monitoring: incidence, associated factors, and clinical course","volume":"32","author":"Yata","year":"2018","journal-title":"J Anesth"},{"key":"10.1016\/j.wneu.2025.123878_bib15","doi-asserted-by":"crossref","first-page":"1155","DOI":"10.1097\/ALN.0b013e3181b8f694","article-title":"Tube-in-tube emergency airway management after a bitten endotracheal tube caused by repetitive transcranial electrical stimulation during spinal cord surgery","volume":"111","author":"Duma","year":"2009","journal-title":"Anesthesiology"},{"key":"10.1016\/j.wneu.2025.123878_bib16","doi-asserted-by":"crossref","first-page":"424","DOI":"10.4103\/0019-5049.118520","article-title":"Loss of integrity of a reinforced endotracheal tube by patient bite","volume":"57","author":"Jain","year":"2013","journal-title":"Indian J Anaesth"},{"key":"10.1016\/j.wneu.2025.123878_bib17","doi-asserted-by":"crossref","first-page":"416","DOI":"10.1097\/00004691-200210000-00005","article-title":"Safety of intraoperative transcranial electrical stimulation motor evoked potential monitoring","volume":"19","author":"MacDonald","year":"2002","journal-title":"J Clin Neurophysiol"},{"key":"10.1016\/j.wneu.2025.123878_bib18","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1016\/B978-0-12-819826-1.00003-X","article-title":"Safety issues during surgical monitoring","volume":"186","author":"Journee","year":"2022","journal-title":"Handb Clin Neurol"},{"key":"10.1016\/j.wneu.2025.123878_bib19","doi-asserted-by":"crossref","first-page":"430","DOI":"10.14245\/ns.2142440.220","article-title":"Intraoperative neuromonitoring during lateral lumbar interbody fusion","volume":"18","author":"Alluri","year":"2021","journal-title":"Neurospine"},{"key":"10.1016\/j.wneu.2025.123878_bib20","doi-asserted-by":"crossref","first-page":"549","DOI":"10.1007\/s10877-015-9713-8","article-title":"Trans-cranial motor evoked potential detection of femoral nerve injury in trans-psoas lateral lumbar interbody fusion","volume":"29","author":"Chaudhary","year":"2015","journal-title":"J Clin Monit Comput"},{"key":"10.1016\/j.wneu.2025.123878_bib21","doi-asserted-by":"crossref","first-page":"296","DOI":"10.1016\/j.spinee.2021.07.017","article-title":"Femoral nerve neuromonitoring for lateral lumbar interbody fusion surgery","volume":"22","author":"Silverstein","year":"2022","journal-title":"Spine J"},{"key":"10.1016\/j.wneu.2025.123878_bib22","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1080\/21646821.2015.1012456","article-title":"Motor evoked potentials for femoral nerve protection in transpsoas lateral access surgery of the spine","volume":"55","author":"Block","year":"2015","journal-title":"Neurodiagn J"},{"key":"10.1016\/j.wneu.2025.123878_bib23","doi-asserted-by":"crossref","first-page":"1254","DOI":"10.1097\/BRS.0000000000000357","article-title":"Saphenous nerve somatosensory evoked potentials: a novel technique to monitor the femoral nerve during transpsoas lumbar lateral interbody fusion","volume":"39","author":"Silverstein","year":"2014","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.1016\/j.wneu.2025.123878_bib24","doi-asserted-by":"crossref","first-page":"1763","DOI":"10.1016\/j.spinee.2018.02.024","article-title":"Use of motor evoked potentials during lateral lumbar interbody fusion reduces postoperative deficits","volume":"18","author":"Riley","year":"2018","journal-title":"Spine J"},{"key":"10.1016\/j.wneu.2025.123878_bib25","first-page":"e655","article-title":"Novel transabdominal motor action potential (TaMAP) neuromonitoring system for spinal surgery","volume":"8","author":"Hoshide","year":"2016","journal-title":"Cureus"},{"key":"10.1016\/j.wneu.2025.123878_bib26","doi-asserted-by":"crossref","first-page":"S37","DOI":"10.1097\/BRS.0b013e3181d8338e","article-title":"The evidence for intraoperative neurophysiological monitoring in spine surgery: does it make a difference?","volume":"35","author":"Fehlings","year":"2010","journal-title":"Spine"},{"key":"10.1016\/j.wneu.2025.123878_bib27","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1007\/s10877-010-9269-6","article-title":"Increases in voltage may produce false-negatives when using transcranial motor evoked potentials to detect an isolated nerve root injury","volume":"24","author":"Lyon","year":"2010","journal-title":"J Clin Monit Comput"},{"key":"10.1016\/j.wneu.2025.123878_bib28","doi-asserted-by":"crossref","first-page":"513","DOI":"10.1097\/WNP.0000000000000796","article-title":"Success rate of obtaining baseline somatosensory and motor evoked potentials in 695 consecutive cranial and spine surgeries","volume":"39","author":"Gonzalez","year":"2022","journal-title":"J Clin Neurophysiol"},{"key":"10.1016\/j.wneu.2025.123878_bib29","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1097\/WNP.0b013e31802ed2d4","article-title":"Success rate of motor evoked potentials for intraoperative neurophysiologic monitoring: effects of age, lesion location, and preoperative neurologic deficits","volume":"24","author":"Chen","year":"2007","journal-title":"J Clin Neurophysiol"},{"key":"10.1016\/j.wneu.2025.123878_bib30","doi-asserted-by":"crossref","first-page":"9","DOI":"10.14245\/kjs.2016.13.1.9","article-title":"The applicability of intraoperative neuromonitoring in patients with preoperative motor weakness during spine surgery","volume":"13","author":"Lee","year":"2016","journal-title":"Korean J Spine"},{"key":"10.1016\/j.wneu.2025.123878_bib31","doi-asserted-by":"crossref","first-page":"31","DOI":"10.3171\/2010.9.SPINE09871","article-title":"Dynamically evoked, discrete-threshold electromyography in the extreme lateral interbody fusion approach","volume":"14","author":"Tohmeh","year":"2011","journal-title":"J Neurosurg Spine"},{"issue":"Suppl 3","key":"10.1016\/j.wneu.2025.123878_bib32","doi-asserted-by":"crossref","first-page":"378","DOI":"10.1007\/s00586-015-3871-8","article-title":"Can triggered electromyography monitoring throughout retraction predict postoperative symptomatic neuropraxia after XLIF? Results from a prospective multicenter trial","volume":"24","author":"Uribe","year":"2015","journal-title":"Eur Spine J"},{"key":"10.1016\/j.wneu.2025.123878_bib33","doi-asserted-by":"crossref","first-page":"1621","DOI":"10.1007\/s11999-011-2088-3","article-title":"Complications of the lateral transpsoas approach for lumbar interbody arthrodesis: a case series and literature review","volume":"470","author":"Sofianos","year":"2012","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.wneu.2025.123878_bib34","doi-asserted-by":"crossref","first-page":"11","DOI":"10.3171\/2011.2.SPINE10374","article-title":"An analysis of postoperative thigh symptoms after minimally invasive transpsoas lumbar interbody fusion","volume":"15","author":"Cummock","year":"2011","journal-title":"J Neurosurg Spine"},{"key":"10.1016\/j.wneu.2025.123878_bib35","doi-asserted-by":"crossref","first-page":"1581","DOI":"10.1007\/s00586-015-4182-9","article-title":"Multimodality intraoperative neuromonitoring in extreme lateral interbody fusion. Transcranial electrical stimulation as indispensable rearview","volume":"25","author":"Berends","year":"2016","journal-title":"Eur Spine J"}],"container-title":["World Neurosurgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1878875025002347?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1878875025002347?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,5,17]],"date-time":"2025-05-17T04:06:44Z","timestamp":1747454804000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1878875025002347"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5]]},"references-count":35,"alternative-id":["S1878875025002347"],"URL":"https:\/\/doi.org\/10.1016\/j.wneu.2025.123878","relation":{},"ISSN":["1878-8750"],"issn-type":[{"value":"1878-8750","type":"print"}],"subject":[],"published":{"date-parts":[[2025,5]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Safety and Feasibility of Transabdominal Muscle Action Potential Monitoring in Lateral Lumbar Surgery","name":"articletitle","label":"Article Title"},{"value":"World Neurosurgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.wneu.2025.123878","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 The Author(s). Published by Elsevier Inc.","name":"copyright","label":"Copyright"}],"article-number":"123878"}}