{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,7]],"date-time":"2026-11-07T13:28:47Z","timestamp":1794058127553,"version":"4.8.0"},"reference-count":39,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,12,1]],"date-time":"2026-12-01T00:00:00Z","timestamp":1796083200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,12,1]],"date-time":"2026-12-01T00:00:00Z","timestamp":1796083200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,10,10]],"date-time":"2026-10-10T00:00:00Z","timestamp":1791590400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["World Neurosurgery"],"published-print":{"date-parts":[[2026,12]]},"DOI":"10.1016\/j.wneu.2026.125418","type":"journal-article","created":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T23:23:34Z","timestamp":1792106614000},"page":"125418","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"special_numbering":"C","title":["A Modular Cranial Phantom for External Ventricular Drain Placement Simulation: Design and Evaluation"],"prefix":"10.1016","volume":"216","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5634-8960","authenticated-orcid":false,"given":"Alessandro","family":"Iop","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6571-0623","authenticated-orcid":false,"given":"Andrii","family":"Matviienko","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ingemar","family":"Markstr\u00f6m","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0000-9554-637X","authenticated-orcid":false,"given":"Jan","family":"Van Frankenhuyzen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John","family":"Van Den Dobbelsteen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0007-2646-0469","authenticated-orcid":false,"given":"Massimo","family":"Bottini","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1039-2098","authenticated-orcid":false,"given":"Victor E.","family":"Staartjes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Victor Gabriel","family":"El-Hajj","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Erik","family":"Edstr\u00f6m","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3776-6136","authenticated-orcid":false,"given":"Adrian","family":"Elmi-Terander","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mario","family":"Romero","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.wneu.2026.125418_bib1","doi-asserted-by":"crossref","first-page":"453","DOI":"10.21037\/atm.2016.12.24","article-title":"Innovations in surgery simulation: a review of past, current and future techniques","volume":"4","author":"Badash","year":"2016","journal-title":"Ann Transl Med"},{"key":"10.1016\/j.wneu.2026.125418_bib2","doi-asserted-by":"crossref","first-page":"1203","DOI":"10.1001\/archsurg.134.11.1203","article-title":"Simulation and virtual reality in surgical education: real or unreal?","volume":"134","author":"Gorman","year":"1999","journal-title":"Arch Surg"},{"key":"10.1016\/j.wneu.2026.125418_bib3","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1023\/A:1008819912213","article-title":"Conceptual and procedural knowledge","volume":"7","author":"McCormick","year":"1997","journal-title":"Int J Technol Des Educ"},{"key":"10.1016\/j.wneu.2026.125418_bib4","doi-asserted-by":"crossref","first-page":"509","DOI":"10.1016\/j.amjsurg.2020.12.016","article-title":"Simulation in surgical education","volume":"221","author":"Lu","year":"2021","journal-title":"Am J Surg"},{"key":"10.1016\/j.wneu.2026.125418_bib5","doi-asserted-by":"crossref","first-page":"304","DOI":"10.3171\/2016.1.JNS152263","article-title":"The relative efficacy of 3 different freehand frontal ventriculostomy trajectories: a prospective neuronavigation-assisted simulation study","volume":"126","author":"Kirkman","year":"2017","journal-title":"J Neurosurg"},{"key":"10.1016\/j.wneu.2026.125418_bib6","doi-asserted-by":"crossref","first-page":"ONS162","DOI":"10.1227\/01.NEU.0000312390.83127.7F","article-title":"Safety and accuracy of bedside external ventricular drain placement","volume":"63","author":"Kakarla","year":"2008","journal-title":"Oper Neurosurg"},{"key":"10.1016\/j.wneu.2026.125418_bib7","first-page":"10","article-title":"Patient-specific polyvinyl alcohol phantom fabrication with ultrasound and x-ray contrast for brain tumor surgery planning","volume":"161","author":"Mackle","year":"2020","journal-title":"J Vis Exp"},{"key":"10.1016\/j.wneu.2026.125418_bib8","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1016\/j.wneu.2018.07.015","article-title":"Effectiveness of cadaveric simulation in neurosurgical training: a review of the literature","volume":"118","author":"Gnanakumar","year":"2018","journal-title":"World Neurosurg"},{"key":"10.1016\/j.wneu.2026.125418_bib13","doi-asserted-by":"crossref","first-page":"6067","DOI":"10.3390\/s22166067","article-title":"Extended reality in neurosurgical education: a systematic review","volume":"22","author":"Iop","year":"2022","journal-title":"Sensors"},{"key":"10.1016\/j.wneu.2026.125418_bib14","series-title":"Extended Abstracts of the CHI Conference on Human Factors in Computing Systems","first-page":"1","article-title":"Exploring the influence of object shapes and colors on depth perception in virtual reality for minimally invasive neurosurgical training","author":"Iop","year":"2024"},{"key":"10.1016\/j.wneu.2026.125418_bib15","series-title":"Extended Abstracts of the 2021 CHI Conference on Human Factors in Computing Systems","first-page":"1","article-title":"A study on the size of tangible organ-shaped controllers for exploring medical data in vr","author":"Reinschluessel","year":"2021"},{"key":"10.1016\/j.wneu.2026.125418_bib16","doi-asserted-by":"crossref","DOI":"10.3389\/fsurg.2022.821060","article-title":"Virtual reality for surgical planning\u2013evaluation based on two liver tumor resections","volume":"9","author":"Reinschluessel","year":"2022","journal-title":"Front Surg"},{"key":"10.1016\/j.wneu.2026.125418_bib17","series-title":"CHI Conference on Human Factors in Computing Systems Extended Abstracts","first-page":"1","article-title":"Evaluating soft organ-shaped tangibles for medical virtual reality","author":"Muender","year":"2022"},{"key":"10.1016\/j.wneu.2026.125418_bib18","series-title":"2024 IEEE Conference on Virtual Reality and 3D User Interfaces Abstracts and Workshops (VRW).","first-page":"117","article-title":"Did I do well? Personalized assessment of trainees\u2019 performance in augmented reality-assisted neurosurgical training","author":"Eom","year":"2024"},{"key":"10.1016\/j.wneu.2026.125418_bib19","doi-asserted-by":"crossref","first-page":"S256","DOI":"10.1016\/j.neuroimage.2010.03.007","article-title":"A head phantom prototype to verify subdural electrode localization tools in epilepsy surgery","volume":"54","author":"Ku\u00df","year":"2011","journal-title":"Neuroimage"},{"key":"10.1016\/j.wneu.2026.125418_bib20","doi-asserted-by":"crossref","first-page":"537","DOI":"10.3390\/bioengineering9100537","article-title":"Development of a CT-compatible, anthropomorphic skull and brain phantom for neurosurgical planning, training, and simulation","volume":"9","author":"Lai","year":"2022","journal-title":"Bioengineering"},{"key":"10.1016\/j.wneu.2026.125418_bib21","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s10916-024-02133-4","article-title":"Development and validation of a neurosurgical phantom for simulating external ventricular drain placement","volume":"49","author":"Van Doormaal","year":"2025","journal-title":"J Med Syst"},{"key":"10.1016\/j.wneu.2026.125418_bib22","article-title":"3D printing surgical phantoms and their role in the visualization of medical procedures","volume":"6","author":"Higgins","year":"2022","journal-title":"Ann 3D Print Med"},{"key":"10.1016\/j.wneu.2026.125418_bib23","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1186\/s41205-021-00099-4","article-title":"3D printing in neurosurgery education: a review","volume":"7","author":"Thiong\u2019o","year":"2021","journal-title":"3D Print Med"},{"key":"10.1016\/j.wneu.2026.125418_bib24","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1016\/j.matdes.2016.09.063","article-title":"A composite hydrogel for brain tissue phantoms","volume":"112","author":"Forte","year":"2016","journal-title":"Mater Des"},{"key":"10.1016\/j.wneu.2026.125418_bib25","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1016\/j.ultras.2014.11.004","article-title":"MRI compatible head phantom for ultrasound surgery","volume":"57","author":"Menikou","year":"2015","journal-title":"Ultrasonics"},{"key":"10.1016\/j.wneu.2026.125418_bib26","doi-asserted-by":"crossref","first-page":"3234","DOI":"10.1118\/1.2219091","article-title":"A realistic phantom for brain-shift simulations","volume":"33","author":"Reinertsen","year":"2006","journal-title":"Med Phys"},{"key":"10.1016\/j.wneu.2026.125418_bib31","doi-asserted-by":"crossref","first-page":"314","DOI":"10.3171\/jns.2004.101.2.0314","article-title":"A realistic brain tissue phantom for intraparenchymal infusion studies","volume":"101","author":"Chen","year":"2004","journal-title":"J Neurosurg"},{"key":"10.1016\/j.wneu.2026.125418_bib32","doi-asserted-by":"crossref","first-page":"1070","DOI":"10.3171\/2014.12.JNS141867","article-title":"Development of a 3D-printed external ventricular drain placement simulator: technical note","volume":"123","author":"Tai","year":"2015","journal-title":"J Neurosurg"},{"key":"10.1016\/j.wneu.2026.125418_bib33","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1227\/ons.0000000000000272","article-title":"Overcoming barriers in neurosurgical education: a novel approach to practical ventriculostomy simulation","volume":"23","author":"Amini","year":"2022","journal-title":"Operative Neurosurg"},{"key":"10.1016\/j.wneu.2026.125418_bib34","article-title":"The effect of augmented reality on the accuracy and learning curve of external ventricular drain placement","volume":"51","author":"Gestel","year":"2021","journal-title":"Neurosurg Focus"},{"key":"10.1016\/j.wneu.2026.125418_bib35","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1007\/s10055-026-01338-x","article-title":"Towards the target and not beyond: 2D vs 3D visual aids in MR-based neurosurgical simulation","volume":"30","author":"Cascarano","year":"2026","journal-title":"Virtual Real"},{"key":"10.1016\/j.wneu.2026.125418_bib36","doi-asserted-by":"crossref","first-page":"884","DOI":"10.1227\/neu.0000000000002293","article-title":"Improved accuracy and lowered learning curve of ventricular targeting using augmented reality-phantom and cadaveric model testing","volume":"92","author":"Bounajem","year":"2023","journal-title":"Neurosurgery"},{"key":"10.1016\/j.wneu.2026.125418_bib37","doi-asserted-by":"crossref","first-page":"6497","DOI":"10.1109\/TVCG.2024.3518258","article-title":"EVD surgical guidance with retro-reflective tool tracking and spatial reconstruction using head-mounted augmented reality device","volume":"31","author":"Li","year":"2025","journal-title":"IEEE Trans Vis Comput Graph"},{"key":"10.1016\/j.wneu.2026.125418_bib38","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1049\/htl2.12066","article-title":"Clinical trainee performance on task-based AR\/VR-guided surgical simulation is correlated with their 3D image spatial reasoning scores","volume":"11","author":"Eagleson","year":"2024","journal-title":"Healthc Technol Lett"},{"key":"10.1016\/j.wneu.2026.125418_bib39","doi-asserted-by":"crossref","first-page":"3913","DOI":"10.1109\/TVCG.2024.3390680","article-title":"Augmented reality-based contextual guidance through surgical tool tracking in neurosurgery","volume":"31","author":"Eom","year":"2025","journal-title":"IEEE Trans Vis Comput Graph"},{"key":"10.1016\/j.wneu.2026.125418_bib40","article-title":"Smart haptic gloves for virtual reality surgery simulation: a pilot study on external ventricular drain training","volume":"10","author":"Boutin","year":"2023","journal-title":"Front Robot AI"},{"key":"10.1016\/j.wneu.2026.125418_bib41","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1080\/02688697.2026.2620411","article-title":"Implementation of real-time intraoperative ultrasound and accuracy of transfrontal primary external ventricular drain placement following high-fidelity surgical simulation training","volume":"40","author":"Kotecha","year":"2026","journal-title":"Br J Neurosurg"},{"key":"10.1016\/j.wneu.2026.125418_bib42","article-title":"External Ventricular Drain (EVD) placement using a Hands-On training session on a simple three-dimensional (3D) model","volume":"14","author":"Podkovik","year":"2022","journal-title":"Cureus"},{"key":"10.1016\/j.wneu.2026.125418_bib43","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1109\/MCG.2004.1274062","article-title":"Haptics in minimally invasive surgical simulation and training","volume":"24","author":"Basdogan","year":"2004","journal-title":"IEEE Comput Graph Appl"},{"key":"10.1016\/j.wneu.2026.125418_bib44","doi-asserted-by":"crossref","first-page":"1015","DOI":"10.1016\/j.wneu.2017.06.140","article-title":"Virtual reality and simulation in neurosurgical training","volume":"106","author":"Bernardo","year":"2017","journal-title":"World Neurosurg"},{"key":"10.1016\/j.wneu.2026.125418_bib45","doi-asserted-by":"crossref","first-page":"e850","DOI":"10.1016\/j.wneu.2019.08.262","article-title":"A systematic review of simulation-based training in neurosurgery, part 1: cranial neurosurgery","volume":"133","author":"Patel","year":"2020","journal-title":"World Neurosurg"},{"key":"10.1016\/j.wneu.2026.125418_bib46","doi-asserted-by":"crossref","first-page":"436","DOI":"10.4253\/wjge.v6.i9.436","article-title":"Evaluation of surgical training in the era of simulation","volume":"6","author":"Shaharan","year":"2014","journal-title":"World J Gastrointest Endosc"},{"key":"10.1016\/j.wneu.2026.125418_bib47","doi-asserted-by":"crossref","first-page":"622","DOI":"10.1016\/j.surg.2009.10.068","article-title":"Methodologies for establishing validity in surgical simulation studies","volume":"147","author":"Van Nortwick","year":"2010","journal-title":"Surgery"}],"container-title":["World Neurosurgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1878875026006340?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1878875026006340?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,11,7]],"date-time":"2026-11-07T13:10:41Z","timestamp":1794057041000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1878875026006340"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,12]]},"references-count":39,"alternative-id":["S1878875026006340"],"URL":"https:\/\/doi.org\/10.1016\/j.wneu.2026.125418","relation":{},"ISSN":["1878-8750"],"issn-type":[{"value":"1878-8750","type":"print"}],"subject":[],"published":{"date-parts":[[2026,12]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"A Modular Cranial Phantom for External Ventricular Drain Placement Simulation: Design and Evaluation","name":"articletitle","label":"Article Title"},{"value":"World Neurosurgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.wneu.2026.125418","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 The Author(s). Published by Elsevier Inc.","name":"copyright","label":"Copyright"}],"article-number":"125418"}}