{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,4]],"date-time":"2026-02-04T17:41:09Z","timestamp":1770226869461,"version":"3.49.0"},"reference-count":20,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2023,12,1]],"date-time":"2023-12-01T00:00:00Z","timestamp":1701388800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2023,12,1]],"date-time":"2023-12-01T00:00:00Z","timestamp":1701388800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2023,9,22]],"date-time":"2023-09-22T00:00:00Z","timestamp":1695340800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["jtcvsopen.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["JTCVS Open"],"published-print":{"date-parts":[[2023,12]]},"DOI":"10.1016\/j.xjon.2023.09.028","type":"journal-article","created":{"date-parts":[[2023,9,26]],"date-time":"2023-09-26T12:19:08Z","timestamp":1695730748000},"page":"909-915","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":6,"special_numbering":"C","title":["The process and safety of removing chest tubes 4 to 12 hours after robotic pulmonary lobectomy and segmentectomy"],"prefix":"10.1016","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4991-2807","authenticated-orcid":false,"given":"Ashley J.","family":"McCormack","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mohamed","family":"El Zaeedi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Travis C.","family":"Geraci","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Robert J.","family":"Cerfolio","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.xjon.2023.09.028_bib1","doi-asserted-by":"crossref","first-page":"e65","DOI":"10.1093\/ejcts\/ezv476","article-title":"Variability in length of stay after uncomplicated pulmonary lobectomy: is length of stay a quality metric or a patient metric?","volume":"49","author":"Giambrone","year":"2016","journal-title":"Eur J Cardio Thorac Surg"},{"key":"10.1016\/j.xjon.2023.09.028_bib2","doi-asserted-by":"crossref","first-page":"667","DOI":"10.1016\/j.jtcvs.2019.08.038","article-title":"Postoperative day 1 discharge after anatomic lung resection: a Society of Thoracic Surgeons database analysis","volume":"159","author":"Linden","year":"2020","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.xjon.2023.09.028_bib3","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1016\/j.jtcvs.2007.08.066","article-title":"Results of a prospective algorithm to remove chest tubes after pulmonary resection with high output","volume":"135","author":"Cerfolio","year":"2008","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.xjon.2023.09.028_bib4","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1016\/j.thorsurg.2007.10.002","article-title":"The influence of preoperative risk stratification on fast-tracking patients after pulmonary resection","volume":"18","author":"Bryant","year":"2008","journal-title":"Thorac Surg Clin"},{"key":"10.1016\/j.xjon.2023.09.028_bib5","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1016\/j.athoracsur.2014.02.051","article-title":"Performing robotic lobectomy and segmentectomy: cost, profitability, and outcomes","volume":"98","author":"Nasir","year":"2014","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.xjon.2023.09.028_bib6","doi-asserted-by":"crossref","first-page":"22","DOI":"10.21037\/jovs.2017.01.06","article-title":"Robotic surgery for lung resections-total port approach: advantages and disadvantages","volume":"3","author":"Ramadan","year":"2017","journal-title":"J Vis Surg"},{"key":"10.1016\/j.xjon.2023.09.028_bib7","doi-asserted-by":"crossref","first-page":"816","DOI":"10.1378\/chest.128.2.816","article-title":"The management of chest tubes in patients with a pneumothorax and an air leak after pulmonary resection","volume":"128","author":"Cerfolio","year":"2005","journal-title":"Chest"},{"key":"10.1016\/j.xjon.2023.09.028_bib8","doi-asserted-by":"crossref","first-page":"232","DOI":"10.1016\/j.athoracsur.2014.03.003","article-title":"The incidence and management of postoperative chylothorax after pulmonary resection and thoracic mediastinal lymph node dissection","volume":"98","author":"Bryant","year":"2014","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.xjon.2023.09.028_bib9","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1093\/ejcts\/ezy301","article-title":"Guidelines for enhanced recovery after lung surgery: recommendations of the Enhanced Recovery After Surgery (ERAS\u00ae) Society and the European Society of Thoracic Surgeons (ESTS)","volume":"55","author":"Batchelor","year":"2019","journal-title":"Eur J Cardio Thorac Surg"},{"key":"10.1016\/j.xjon.2023.09.028_bib10","doi-asserted-by":"crossref","first-page":"1690","DOI":"10.1016\/j.athoracsur.2009.01.077","article-title":"The removal of chest tubes despite an air leak or a pneumothorax","volume":"87","author":"Cerfolio","year":"2009","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.xjon.2023.09.028_bib11","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1016\/j.thorsurg.2020.04.006","article-title":"Intraoperative anesthetic and surgical concerns for robotic thoracic surgery","volume":"30","author":"Geraci","year":"2020","journal-title":"Thorac Surg Clin"},{"key":"10.1016\/j.xjon.2023.09.028_bib12","article-title":"Efficiency Quality Index (EQI)-implementing a novel metric that delivers overall institutional excellence and value for patients","volume":"7","author":"Cerfolio","year":"2020","journal-title":"Front Surg"},{"key":"10.1016\/j.xjon.2023.09.028_bib13","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1016\/j.thorsurg.2021.02.005","article-title":"Postoperative air leaks after lung surgery: predictors, intraoperative techniques, and postoperative management","volume":"31","author":"Geraci","year":"2021","journal-title":"Thorac Surg Clin"},{"key":"10.1016\/j.xjon.2023.09.028_bib14","doi-asserted-by":"crossref","first-page":"234","DOI":"10.1016\/j.athoracsur.2021.06.088","article-title":"Discharging patients by postoperative day one after robotic anatomic pulmonary resection","volume":"114","author":"Geraci","year":"2022","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.xjon.2023.09.028_bib15","doi-asserted-by":"crossref","first-page":"3145","DOI":"10.21037\/jtd-22-574","article-title":"Use of a novel digital drainage system after pulmonary resection","volume":"14","author":"Geraci","year":"2022","journal-title":"J Thorac Dis"},{"key":"10.1016\/j.xjon.2023.09.028_bib16","doi-asserted-by":"crossref","first-page":"396","DOI":"10.1016\/j.athoracsur.2008.04.016","article-title":"The benefits of continuous and digital air leak assessment after elective pulmonary resection: a prospective study","volume":"86","author":"Cerfolio","year":"2008","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.xjon.2023.09.028_bib17","doi-asserted-by":"crossref","first-page":"1005","DOI":"10.1016\/j.athoracsur.2017.03.030","article-title":"The validation of a no-drain policy after thoracoscopic major lung resection","volume":"104","author":"Murakami","year":"2017","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.xjon.2023.09.028_bib18","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1093\/ejcts\/ezs679","article-title":"Omitting chest tube drainage after thoracoscopic major lung resection","volume":"44","author":"Ueda","year":"2013","journal-title":"Eur J Cardio Thorac Surg"},{"key":"10.1016\/j.xjon.2023.09.028_bib19","doi-asserted-by":"crossref","first-page":"657","DOI":"10.1093\/icvts\/ivaa170","article-title":"Early postoperative day 0 chest tube removal using a digital drainage device protocol after thoracoscopic major pulmonary resection","volume":"31","author":"Pfeuty","year":"2020","journal-title":"Interact Cardiovasc Thorac Surg"},{"key":"10.1016\/j.xjon.2023.09.028_bib20","doi-asserted-by":"crossref","first-page":"673","DOI":"10.1093\/ejcts\/ezy361","article-title":"The effects of low suction on digital drainage devices after lobectomy using video-assisted thoracoscopic surgery: a randomized controlled trial","volume":"55","author":"Holbek","year":"2019","journal-title":"Eur J Cardio Thorac Surg"}],"container-title":["JTCVS Open"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2666273623003005?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2666273623003005?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,11,12]],"date-time":"2025-11-12T20:51:36Z","timestamp":1762980696000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2666273623003005"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,12]]},"references-count":20,"alternative-id":["S2666273623003005"],"URL":"https:\/\/doi.org\/10.1016\/j.xjon.2023.09.028","relation":{},"ISSN":["2666-2736"],"issn-type":[{"value":"2666-2736","type":"print"}],"subject":[],"published":{"date-parts":[[2023,12]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"The process and safety of removing chest tubes 4 to 12 hours after robotic pulmonary lobectomy and segmentectomy","name":"articletitle","label":"Article Title"},{"value":"JTCVS Open","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.xjon.2023.09.028","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2023 The Author(s). Published by Elsevier Inc. on behalf of The American Association for Thoracic Surgery.","name":"copyright","label":"Copyright"}]}}