{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,15]],"date-time":"2026-07-15T04:27:00Z","timestamp":1784089620720,"version":"3.55.0"},"reference-count":15,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2024,10,1]],"date-time":"2024-10-01T00:00:00Z","timestamp":1727740800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,10,1]],"date-time":"2024-10-01T00:00:00Z","timestamp":1727740800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,7,12]],"date-time":"2024-07-12T00:00:00Z","timestamp":1720742400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["jtcvstechniques.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["JTCVS Techniques"],"published-print":{"date-parts":[[2024,10]]},"DOI":"10.1016\/j.xjtc.2024.07.007","type":"journal-article","created":{"date-parts":[[2024,7,26]],"date-time":"2024-07-26T18:59:02Z","timestamp":1722020342000},"page":"19-28","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":3,"special_numbering":"C","title":["Transcatheter electrosurgical aortic septostomy optimizes distal landing zone in chronic dissection"],"prefix":"10.1016","volume":"27","author":[{"given":"Alexander P.","family":"Nissen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yazan M.","family":"Duwayri","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"William D.","family":"Jordan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vasilis C.","family":"Babaliaros","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert J.","family":"Lederman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2290-1729","authenticated-orcid":false,"given":"Bradley G.","family":"Leshnower","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"6","key":"10.1016\/j.xjtc.2024.07.007_bib1","doi-asserted-by":"crossref","first-page":"2092","DOI":"10.1016\/j.athoracsur.2014.06.066","article-title":"Thoracic endovascular aortic repair for chronic DeBakey IIIb aortic dissection","volume":"98","author":"Hughes","year":"2014","journal-title":"Ann Thorac Surg"},{"issue":"5","key":"10.1016\/j.xjtc.2024.07.007_bib2","doi-asserted-by":"crossref","first-page":"1074","DOI":"10.1016\/j.jtcvs.2011.03.008","article-title":"Endovascular repair of complicated chronic distal aortic dissections: intermediate outcomes and complications","volume":"142","author":"Kang","year":"2011","journal-title":"J Thorac Cardiovasc Surg"},{"issue":"3","key":"10.1016\/j.xjtc.2024.07.007_bib3","doi-asserted-by":"crossref","first-page":"914","DOI":"10.1016\/j.athoracsur.2012.09.053","article-title":"Thoracic endografting reduces morbidity and remodels the thoracic aorta in DeBakey III aneurysms","volume":"95","author":"Leshnower","year":"2013","journal-title":"Ann Thorac Surg"},{"issue":"6","key":"10.1016\/j.xjtc.2024.07.007_bib4","first-page":"784","article-title":"Techniques and outcomes of false lumen embolization in chronic type B aortic dissection","volume":"59","author":"Rohlffs","year":"2018","journal-title":"J Cardiovasc Surg (Torino)"},{"issue":"1","key":"10.1016\/j.xjtc.2024.07.007_bib5","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1583\/13-4463MR-R.1","article-title":"Addressing persistent false lumen flow in chronic aortic dissection: the knickerbocker technique","volume":"21","author":"K\u00f6lbel","year":"2014","journal-title":"J Endovasc Ther"},{"issue":"25 Pt A","key":"10.1016\/j.xjtc.2024.07.007_bib6","doi-asserted-by":"crossref","first-page":"2795","DOI":"10.1016\/j.jacc.2014.04.015","article-title":"Caval-aortic access to allow transcatheter aortic valve replacement in otherwise ineligible patients: initial human experience","volume":"63","author":"Greenbaum","year":"2014","journal-title":"J Am Coll Cardiol"},{"issue":"1","key":"10.1016\/j.xjtc.2024.07.007_bib7","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1016\/j.jvs.2018.06.200","article-title":"Toronto PowerWire fenestration technique to access false lumen branches in fenestrated endovascular aneurysm repair for chronic type B dissection","volume":"69","author":"Stella","year":"2019","journal-title":"J Vasc Surg"},{"issue":"2","key":"10.1016\/j.xjtc.2024.07.007_bib8","doi-asserted-by":"crossref","first-page":"e183","DOI":"10.4244\/EIJ-D-19-00688","article-title":"Fenestration of an aortic endovascular graft using an electrified coronary guidewire","volume":"16","author":"Sulimov","year":"2020","journal-title":"EuroIntervention"},{"issue":"9","key":"10.1016\/j.xjtc.2024.07.007_bib9","doi-asserted-by":"crossref","first-page":"1437","DOI":"10.1016\/j.radcr.2020.06.015","article-title":"Novel method for\u00a0endovascular fenestration using radiofrequency transseptal needle for aortic dissection with malperfusion syndrome","volume":"15","author":"Yagi","year":"2020","journal-title":"Radiol Case Rep"},{"issue":"5","key":"10.1016\/j.xjtc.2024.07.007_bib10","doi-asserted-by":"crossref","first-page":"511","DOI":"10.1016\/j.jacc.2016.10.024","article-title":"Transcaval access and closure for transcatheter aortic valve replacement: a prospective investigation","volume":"69","author":"Greenbaum","year":"2017","journal-title":"J Am Coll Cardiol"},{"issue":"16","key":"10.1016\/j.xjtc.2024.07.007_bib11","doi-asserted-by":"crossref","first-page":"1745","DOI":"10.1016\/j.jacc.2013.01.057","article-title":"Aortic access from the vena cava for large caliber transcatheter cardiovascular interventions: pre-clinical validation","volume":"61","author":"Halabi","year":"2013","journal-title":"J Am Coll Cardiol"},{"issue":"3","key":"10.1016\/j.xjtc.2024.07.007_bib12","doi-asserted-by":"crossref","first-page":"959","DOI":"10.1016\/j.athoracsur.2019.10.005","article-title":"Society for Vascular Surgery (SVS) and Society of Thoracic Surgeons (STS) reporting standards for type B aortic dissections","volume":"109","author":"Lombardi","year":"2020","journal-title":"Ann Thorac Surg"},{"issue":"5","key":"10.1016\/j.xjtc.2024.07.007_bib13","doi-asserted-by":"crossref","first-page":"1776","DOI":"10.1016\/j.jtcvs.2021.07.049","article-title":"Aortic septotomy to optimize landing zones during thoracic endovascular aortic repair for chronic type B aortic dissection","volume":"165","author":"Fukuhara","year":"2023","journal-title":"J Thorac Cardiovasc Surg"},{"issue":"2","key":"10.1016\/j.xjtc.2024.07.007_bib14","article-title":"Initial experience with a modified \u201ccandy-plug\u201d technique for false lumen embolization in chronic type B aortic dissection","volume":"9","author":"Miles","year":"2023","journal-title":"J Vasc Surg Cases Innov Tech"},{"issue":"2","key":"10.1016\/j.xjtc.2024.07.007_bib15","article-title":"Candy-plug: failure to launch","volume":"9","author":"Sweet","year":"2023","journal-title":"J Vasc Surg Cases Innov Tech"}],"container-title":["JTCVS Techniques"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2666250724002803?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2666250724002803?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2024,10,18]],"date-time":"2024-10-18T06:18:53Z","timestamp":1729232333000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2666250724002803"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,10]]},"references-count":15,"alternative-id":["S2666250724002803"],"URL":"https:\/\/doi.org\/10.1016\/j.xjtc.2024.07.007","relation":{},"ISSN":["2666-2507"],"issn-type":[{"value":"2666-2507","type":"print"}],"subject":[],"published":{"date-parts":[[2024,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Transcatheter electrosurgical aortic septostomy optimizes distal landing zone in chronic dissection","name":"articletitle","label":"Article Title"},{"value":"JTCVS Techniques","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.xjtc.2024.07.007","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 The Author(s). Published by Elsevier Inc. on behalf of The American Association for Thoracic Surgery.","name":"copyright","label":"Copyright"}]}}