{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,5,13]],"date-time":"2025-05-13T21:42:00Z","timestamp":1747172520668,"version":"3.40.5"},"reference-count":33,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2024,8,1]],"date-time":"2024-08-01T00:00:00Z","timestamp":1722470400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,8,1]],"date-time":"2024-08-01T00:00:00Z","timestamp":1722470400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,3,12]],"date-time":"2024-03-12T00:00:00Z","timestamp":1710201600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["jsesreviewsreportstech.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["JSES Reviews, Reports, and Techniques"],"published-print":{"date-parts":[[2024,8]]},"DOI":"10.1016\/j.xrrt.2024.02.003","type":"journal-article","created":{"date-parts":[[2024,3,16]],"date-time":"2024-03-16T09:28:59Z","timestamp":1710581339000},"page":"393-397","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Outcomes following fixation of distal clavicle fractures utilizing arthroscopically assisted coracoclavicular ligament stabilization with a suspensory endobutton and cerclage tape"],"prefix":"10.1016","volume":"4","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9128-9513","authenticated-orcid":false,"given":"Benjamin R.","family":"Campbell","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6630-8487","authenticated-orcid":false,"given":"Philip M.","family":"Petrucelli","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kenneth A.","family":"Kearns","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.xrrt.2024.02.003_bib1","doi-asserted-by":"crossref","first-page":"417","DOI":"10.1097\/BOT.0000000000001481","article-title":"Hook plate fixation for acute unstable distal clavicle fracture: a systematic review and meta-analysis","volume":"33","author":"Asadollahi","year":"2019","journal-title":"J\u00a0Orthop Trauma"},{"key":"10.1016\/j.xrrt.2024.02.003_bib2","doi-asserted-by":"crossref","first-page":"e655","DOI":"10.1016\/j.eats.2015.07.010","article-title":"Arthroscopic-assisted management of unstable distal-third clavicle fractures: conoid ligament reconstruction and fracture cerclage with sutures","volume":"4","author":"Cisneros","year":"2015","journal-title":"Arthrosc Tech"},{"key":"10.1016\/j.xrrt.2024.02.003_bib3","doi-asserted-by":"crossref","first-page":"835","DOI":"10.1016\/j.jseint.2021.05.007","article-title":"Arthroscopic coracoclavicular button fixation versus anatomic locking plate fixation for unstable distal clavicular fractures","volume":"5","author":"Erden","year":"2021","journal-title":"JSES Int"},{"key":"10.1016\/j.xrrt.2024.02.003_bib4","first-page":"167","article-title":"Outcome of operative treatment in fresh lateral clavicular fracture","volume":"76","author":"Eskola","year":"1987","journal-title":"Ann Chir Gynaecol"},{"key":"10.1016\/j.xrrt.2024.02.003_bib5","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1177\/230949900701500103","article-title":"Temporary coracoclavicular screw fixation for displaced distal clavicle fractures","volume":"15","author":"Fazal","year":"2007","journal-title":"J\u00a0Orthop Surg (Hong Kong)"},{"key":"10.1016\/j.xrrt.2024.02.003_bib6","doi-asserted-by":"crossref","first-page":"254","DOI":"10.2106\/JBJS.19.00590","article-title":"Neer type-II distal clavicle fractures: a cost-effectiveness analysis of fixation techniques","volume":"102","author":"Fox","year":"2020","journal-title":"J\u00a0Bone Joint Surg Am"},{"key":"10.1016\/j.xrrt.2024.02.003_bib7","first-page":"1358","article-title":"Surgical treatment for distal clavicle fracture associated with coracoclavicular ligament rupture using a cannulated screw fixation technique","volume":"60","author":"Jin","year":"2006","journal-title":"J\u00a0Trauma"},{"key":"10.1016\/j.xrrt.2024.02.003_bib8","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1016\/j.jse.2007.04.012","article-title":"A\u00a0method for internal fixation of unstable distal clavicle fractures: early observations using a new technique","volume":"17","author":"Kalamaras","year":"2008","journal-title":"J\u00a0Shoulder Elbow Surg"},{"key":"10.1016\/j.xrrt.2024.02.003_bib9","doi-asserted-by":"crossref","first-page":"522","DOI":"10.1097\/00005373-200109000-00016","article-title":"Treatment of distal clavicle fracture using kirschner wires and tension-band wires","volume":"51","author":"Kao","year":"2001","journal-title":"J\u00a0Trauma Acute Care Surg"},{"key":"10.1016\/j.xrrt.2024.02.003_bib10","doi-asserted-by":"crossref","first-page":"158","DOI":"10.1097\/01.blo.0000203469.66055.6a","article-title":"Surgical treatment of distal clavicle fractures using the clavicular hook plate","volume":"447","author":"Kashii","year":"2006","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.xrrt.2024.02.003_bib11","doi-asserted-by":"crossref","first-page":"447","DOI":"10.2106\/JBJS.H.00034","article-title":"Fractures of the clavicle","volume":"91","author":"Khan","year":"2009","journal-title":"J\u00a0Bone Joint Surg Am"},{"key":"10.1016\/j.xrrt.2024.02.003_bib12","doi-asserted-by":"crossref","first-page":"135","DOI":"10.4055\/cios20010","article-title":"Current concepts for classification and treatment of distal clavicle fractures","volume":"12","author":"Kim","year":"2020","journal-title":"Clin Orthop Surg"},{"key":"10.1016\/j.xrrt.2024.02.003_bib13","doi-asserted-by":"crossref","first-page":"1283","DOI":"10.1007\/s00402-015-2271-1","article-title":"Arthroscopically assisted stabilization of displaced lateral clavicle fractures with coracoclavicular instability","volume":"135","author":"Kraus","year":"2015","journal-title":"Arch Orthop Trauma Surg"},{"key":"10.1016\/j.xrrt.2024.02.003_bib14","doi-asserted-by":"crossref","first-page":"1701","DOI":"10.1007\/s00264-018-4108-3","article-title":"Complications with the clavicle hook plate after fixation of Neer type II clavicle fractures","volume":"43","author":"Lopiz","year":"2019","journal-title":"Int Orthop"},{"key":"10.1016\/j.xrrt.2024.02.003_bib15","doi-asserted-by":"crossref","first-page":"1429","DOI":"10.1007\/s00167-013-2772-9","article-title":"Outcome of arthroscopic treatment for displaced lateral clavicle fractures using a double button device","volume":"23","author":"Loriaut","year":"2015","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"10.1016\/j.xrrt.2024.02.003_bib16","doi-asserted-by":"crossref","first-page":"1189","DOI":"10.1007\/s00167-012-2089-0","article-title":"Treatment for unstable distal clavicle fractures (Neer 2) with locking T-plate and additional PDS cerclage","volume":"21","author":"Martetschl\u00e4ger","year":"2013","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"10.1016\/j.xrrt.2024.02.003_bib17","doi-asserted-by":"crossref","first-page":"423","DOI":"10.1016\/j.jse.2011.08.053","article-title":"Treatment of clavicle fractures: current concepts review","volume":"21","author":"van der Meijden","year":"2012","journal-title":"J\u00a0Shoulder Elbow Surg"},{"key":"10.1016\/j.xrrt.2024.02.003_bib18","doi-asserted-by":"crossref","first-page":"1393","DOI":"10.1007\/s00402-019-03219-2","article-title":"Outcome of arthroscopy-assisted treatment for distal clavicle fractures","volume":"139","author":"Mochizuki","year":"2019","journal-title":"Arch Orthop Trauma Surg"},{"key":"10.1016\/j.xrrt.2024.02.003_bib19","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1097\/00003086-196805000-00007","article-title":"Fractures of the distal third of the clavicle","volume":"58","author":"Neer","year":"1968","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.xrrt.2024.02.003_bib20","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1186\/s13018-022-03108-2","article-title":"What is the optimal surgical treatment for Neer type IIB (IIC) distal clavicle fractures? A systematic review and meta-analysis","volume":"17","author":"Panagopoulos","year":"2022","journal-title":"J\u00a0Orthop Surg Res"},{"key":"10.1016\/j.xrrt.2024.02.003_bib21","doi-asserted-by":"crossref","first-page":"452","DOI":"10.1067\/mse.2002.126613","article-title":"Epidemiology of clavicle fractures","volume":"11","author":"Postacchini","year":"2002","journal-title":"J\u00a0Shoulder Elbow Surg"},{"key":"10.1016\/j.xrrt.2024.02.003_bib22","doi-asserted-by":"crossref","first-page":"110","DOI":"10.1007\/s101430100186","article-title":"Intraspinal migration of a Kirschner wire 3 months after clavicular fracture fixation","volume":"25","author":"Regel","year":"2002","journal-title":"Neurosurg Rev"},{"key":"10.1016\/j.xrrt.2024.02.003_bib23","doi-asserted-by":"crossref","first-page":"778","DOI":"10.2106\/00004623-200404000-00016","article-title":"Primary nonoperative treatment of displaced lateral fractures of the clavicle","volume":"86","author":"Robinson","year":"2004","journal-title":"J\u00a0Bone Joint Surg Am"},{"key":"10.1016\/j.xrrt.2024.02.003_bib24","doi-asserted-by":"crossref","first-page":"1359","DOI":"10.2106\/00004623-200407000-00002","article-title":"Estimating the risk of nonunion following nonoperative treatment of a clavicular fracture","volume":"86","author":"Robinson","year":"2004","journal-title":"J\u00a0Bone Joint Surg Am"},{"key":"10.1016\/j.xrrt.2024.02.003_bib25","doi-asserted-by":"crossref","first-page":"2570","DOI":"10.1016\/j.jse.2021.03.151","article-title":"Functional outcomes and complications following combined locking plate and tunneled suspensory device fixation of lateral-end clavicle nonunions","volume":"30","author":"Robinson","year":"2021","journal-title":"J\u00a0Shoulder Elbow Surg"},{"key":"10.1016\/j.xrrt.2024.02.003_bib26","doi-asserted-by":"crossref","first-page":"94","DOI":"10.1097\/BTH.0000000000000203","article-title":"Arthroscopy-assisted treatment of displaced distal clavicle fractures utilizing curved buttons and suture tape with a single coracoclavicular tunnel","volume":"22","author":"Rose","year":"2018","journal-title":"Tech Hand Up Extrem Surg"},{"key":"10.1016\/j.xrrt.2024.02.003_bib27","doi-asserted-by":"crossref","first-page":"1237","DOI":"10.1016\/j.otsr.2018.07.025","article-title":"Arthroscopy-assisted fixation of fracture of the distal part of the clavicle by subcoracoid suture and clavicle button","volume":"104","author":"Sautet","year":"2018","journal-title":"Orthop Traumatol Surg Res"},{"key":"10.1016\/j.xrrt.2024.02.003_bib28","doi-asserted-by":"crossref","first-page":"853","DOI":"10.1016\/j.otsr.2019.03.012","article-title":"Complications after surgical treatment of distal clavicle fractures","volume":"105","author":"Singh","year":"2019","journal-title":"Orthop Traumatol Surg Res"},{"key":"10.1016\/j.xrrt.2024.02.003_bib29","doi-asserted-by":"crossref","DOI":"10.1177\/2325967116657810","article-title":"Closed-loop double endobutton technique for repair of unstable distal clavicle fractures","volume":"4","author":"Struhl","year":"2016","journal-title":"Orthop J Sports Med"},{"key":"10.1016\/j.xrrt.2024.02.003_bib30","doi-asserted-by":"crossref","first-page":"399","DOI":"10.1007\/s00402-011-1455-6","article-title":"Arthroscopic stabilization for Neer type 2 fracture of the distal clavicle fracture","volume":"132","author":"Takase","year":"2012","journal-title":"Arch Orthop Trauma Surg"},{"key":"10.1016\/j.xrrt.2024.02.003_bib31","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1186\/s13018-021-02904-6","article-title":"Different internal fixation methods for unstable distal clavicle fractures in adults: a systematic review and network meta-analysis","volume":"17","author":"Xu","year":"2022","journal-title":"J\u00a0Orthop Surg Res"},{"key":"10.1016\/j.xrrt.2024.02.003_bib32","doi-asserted-by":"crossref","first-page":"982","DOI":"10.1016\/j.jse.2018.11.041","article-title":"A\u00a0biomechanical comparison of new techniques for distal clavicular fracture repair versus locked plating","volume":"28","author":"Yagnik","year":"2019","journal-title":"J\u00a0Shoulder Elbow Surg"},{"key":"10.1016\/j.xrrt.2024.02.003_bib33","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1186\/s13018-019-1073-5","article-title":"Treatment of unstable distal-third clavicule fractures using minimal invasive closed-loop double endobutton technique","volume":"14","author":"Zheng","year":"2019","journal-title":"J\u00a0Orthop Surg Res"}],"container-title":["JSES Reviews, Reports, and Techniques"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2666639124000324?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2666639124000324?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2024,7,26]],"date-time":"2024-07-26T22:15:51Z","timestamp":1722032151000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2666639124000324"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,8]]},"references-count":33,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2024,8]]}},"alternative-id":["S2666639124000324"],"URL":"https:\/\/doi.org\/10.1016\/j.xrrt.2024.02.003","relation":{},"ISSN":["2666-6391"],"issn-type":[{"type":"print","value":"2666-6391"}],"subject":[],"published":{"date-parts":[[2024,8]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Outcomes following fixation of distal clavicle fractures utilizing arthroscopically assisted coracoclavicular ligament stabilization with a suspensory endobutton and cerclage tape","name":"articletitle","label":"Article Title"},{"value":"JSES Reviews, Reports, and Techniques","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.xrrt.2024.02.003","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 The Author(s). Published by Elsevier Inc. on behalf of American Shoulder & Elbow Surgeons.","name":"copyright","label":"Copyright"}]}}