{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T22:52:15Z","timestamp":1791327135822,"version":"4.3.1"},"reference-count":30,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2027,1,1]],"date-time":"2027-01-01T00:00:00Z","timestamp":1798761600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2027,1,1]],"date-time":"2027-01-01T00:00:00Z","timestamp":1798761600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T00:00:00Z","timestamp":1790726400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100003042","name":"Else Kr\u00f6ner Fresenius Foundation","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100003042","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Regulatory Toxicology and Pharmacology"],"published-print":{"date-parts":[[2027,1]]},"DOI":"10.1016\/j.yrtph.2026.106265","type":"journal-article","created":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T15:10:26Z","timestamp":1790781026000},"page":"106265","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"special_numbering":"C","title":["Biological-safety-by-design for bioresorbable intravascular drug-delivery implants: Operationalizing ISO 10993-1:2025 across device, degradation, and payload states"],"prefix":"10.1016","volume":"173","author":[{"ORCID":"https:\/\/orcid.org\/0009-0009-8760-3931","authenticated-orcid":false,"given":"Anna","family":"Fleischer","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4268-6154","authenticated-orcid":false,"given":"Johannes","family":"Braig","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tomasz","family":"J\u00fcngst","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Valentin","family":"Schwer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Heinz","family":"Schwer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0048-0302","authenticated-orcid":false,"given":"Oliver","family":"Sch\u00f6ffski","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.yrtph.2026.106265_bib1","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1016\/j.smim.2007.11.004","article-title":"Foreign body reaction to biomaterials","volume":"20","author":"Anderson","year":"2008","journal-title":"Semin. Immunol."},{"issue":"1","key":"10.1016\/j.yrtph.2026.106265_bib2","first-page":"78","article-title":"Material-mediated pyrogens in medical devices: myth or reality?","volume":"43","author":"Borton","year":"2026","journal-title":"ALTEX"},{"key":"10.1016\/j.yrtph.2026.106265_bib3","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1002\/jbm.b.35130","article-title":"Development of a novel low-background noise blood loop model for testing blood-contacting biomaterials and medical devices in fresh human blood","volume":"111","author":"Cahalan","year":"2023","journal-title":"J. Biomed. Mater. Res. B Appl. Biomater."},{"key":"10.1016\/j.yrtph.2026.106265_bib4","volume":"2026\/1231","year":"2026","journal-title":"Orkesterjournalen L"},{"key":"10.1016\/j.yrtph.2026.106265_bib5","first-page":"1","article-title":"Regulation (EU) 2017\/745 of 5 April 2017 on medical devices","volume":"L117","year":"2017","journal-title":"Off. J. Eur. Union"},{"key":"10.1016\/j.yrtph.2026.106265_bib6","series-title":"Guidance for Industry and Food and Drug Administration Staff","article-title":"Use of international standard ISO 10993-1, \"Biological evaluation of medical devices - part 1: evaluation and testing within a risk management process\"","year":"2023"},{"key":"10.1016\/j.yrtph.2026.106265_bib7","series-title":"Recognized Consensus Standards: ISO 10993-1","year":"2026"},{"key":"10.1016\/j.yrtph.2026.106265_bib8","doi-asserted-by":"crossref","DOI":"10.1016\/j.yrtph.2022.105164","article-title":"Report on investigation of ISO 10993-12 extraction conditions","volume":"131","author":"Heise","year":"2022","journal-title":"Regul. Toxicol. Pharmacol."},{"key":"10.1016\/j.yrtph.2026.106265_bib9","doi-asserted-by":"crossref","DOI":"10.3389\/fmedt.2022.1006984","article-title":"A case study: re-evaluating the biological risk following a processing aid change on a marketed cardiovascular implant device","volume":"4","author":"Hsia","year":"2022","journal-title":"Front. Med. Technol."},{"key":"10.1016\/j.yrtph.2026.106265_bib10","series-title":"ISO 10993-4:2017, Biological Evaluation of Medical Devices - Part 4: Selection of Tests for Interactions with Blood, Including Amendment 1:2025","year":"2017"},{"key":"10.1016\/j.yrtph.2026.106265_bib11","series-title":"ISO 10993-16:2017, Biological Evaluation of Medical Devices - Part 16: Toxicokinetic Study Design for Degradation Products and Leachables","year":"2017"},{"key":"10.1016\/j.yrtph.2026.106265_bib12","series-title":"ISO 10993-1:2018, Biological Evaluation of Medical Devices - Part 1: Evaluation and Testing Within a Risk Management Process","year":"2018"},{"key":"10.1016\/j.yrtph.2026.106265_bib13","series-title":"ISO 10993-9:2019, Biological Evaluation of Medical Devices - Part 9: Framework for Identification and Quantification of Potential Degradation Products","year":"2019"},{"key":"10.1016\/j.yrtph.2026.106265_bib14","series-title":"ISO 14971:2019, Medical Devices - Application of Risk Management to Medical Devices","year":"2019"},{"key":"10.1016\/j.yrtph.2026.106265_bib15","series-title":"Including Amendment 1:2022 (Determination of the Uncertainty Factor)","article-title":"ISO 10993-18:2020, biological evaluation of medical devices - part 18: chemical characterization of medical device materials within a risk management process","year":"2020"},{"key":"10.1016\/j.yrtph.2026.106265_bib16","series-title":"Including Amendment 1:2025","article-title":"ISO 10993-12:2021, biological evaluation of medical devices - part 12: sample preparation and reference materials","year":"2021"},{"key":"10.1016\/j.yrtph.2026.106265_bib17","series-title":"ISO\/TS 37137-1:2021, Biological Evaluation of Absorbable Medical Devices - Part 1: General Requirements","year":"2021"},{"key":"10.1016\/j.yrtph.2026.106265_bib18","series-title":"ISO 10993-17:2023, Biological Evaluation of Medical Devices - Part 17: Toxicological Risk Assessment of Medical Device Constituents, Including Amendment 1:2025","year":"2023"},{"key":"10.1016\/j.yrtph.2026.106265_bib19","series-title":"ISO 10993-1:2025, Biological Evaluation of Medical Devices - Part 1: Requirements and General Principles for the Evaluation of Biological Safety Within a Risk Management Process","year":"2025"},{"key":"10.1016\/j.yrtph.2026.106265_bib20","series-title":"ISO 10993-6:2026, Biological Evaluation of Medical Devices - Part 6: Tests for Local Effects After Implantation","year":"2026"},{"key":"10.1016\/j.yrtph.2026.106265_bib21","doi-asserted-by":"crossref","DOI":"10.1016\/j.mrrev.2021.108407","article-title":"Genotoxicity evaluation of medical devices: a regulatory perspective","volume":"789","author":"Kumaravel","year":"2022","journal-title":"Mutat. Res. Rev. Mutat. Res."},{"key":"10.1016\/j.yrtph.2026.106265_bib22","first-page":"269","article-title":"Strategy on biological evaluation for biodegradable\/absorbable materials and medical devices","volume":"29","author":"Liu","year":"2018","journal-title":"Bio Med. Mater. Eng."},{"key":"10.1016\/j.yrtph.2026.106265_bib23","doi-asserted-by":"crossref","first-page":"146","DOI":"10.1016\/j.thromres.2020.07.027","article-title":"In vitro hemocompatibility testing of medical devices","volume":"195","author":"Nalezinkov\u00e1","year":"2020","journal-title":"Thromb. Res."},{"key":"10.1016\/j.yrtph.2026.106265_bib24","doi-asserted-by":"crossref","first-page":"1465","DOI":"10.1021\/acs.biomac.9b00159","article-title":"Biocompatibility of resorbable polymers: a historical perspective and framework for the future","volume":"20","author":"Pappalardo","year":"2019","journal-title":"Biomacromolecules"},{"key":"10.1016\/j.yrtph.2026.106265_bib25","doi-asserted-by":"crossref","DOI":"10.1016\/j.yrtph.2024.105590","article-title":"Taring the scales: Weight-of-evidence framework for biocompatibility evaluations","volume":"149","author":"Street","year":"2024","journal-title":"Regul. Toxicol. Pharmacol."},{"key":"10.1016\/j.yrtph.2026.106265_bib26","doi-asserted-by":"crossref","DOI":"10.1016\/j.yrtph.2024.105622","article-title":"Is read-across for chemicals comparable to medical device equivalence and where to use it for conformity assessment?","volume":"149","author":"S\u00fcndermann","year":"2024","journal-title":"Regul. Toxicol. Pharmacol."},{"key":"10.1016\/j.yrtph.2026.106265_bib27","doi-asserted-by":"crossref","first-page":"939","DOI":"10.1021\/acsbiomaterials.1c01119","article-title":"Chemical characterization and non-targeted analysis of medical device extracts: a review of current approaches, gaps, and emerging practices","volume":"8","author":"Sussman","year":"2022","journal-title":"ACS Biomater. Sci. Eng."},{"key":"10.1016\/j.yrtph.2026.106265_bib28","doi-asserted-by":"crossref","first-page":"1068","DOI":"10.1007\/s10439-025-03702-5","article-title":"Chemical characterization in medical device evaluation: current practices, regulatory requirements, and future directions","volume":"53","author":"Szymanski","year":"2025","journal-title":"Ann. Biomed. Eng."},{"key":"10.1016\/j.yrtph.2026.106265_bib29","doi-asserted-by":"crossref","first-page":"99","DOI":"10.3389\/fbioe.2018.00099","article-title":"Blood-contacting biomaterials: in vitro evaluation of the hemocompatibility","volume":"6","author":"Weber","year":"2018","journal-title":"Front. Bioeng. Biotechnol."},{"key":"10.1016\/j.yrtph.2026.106265_bib30","doi-asserted-by":"crossref","DOI":"10.3389\/ftox.2026.1766769","article-title":"Compositional profiling for biodegradable medical devices: a framework for degradation-informed exposure and risk assessment","volume":"8","author":"Wilsey","year":"2026","journal-title":"Front. Toxicol."}],"container-title":["Regulatory Toxicology and Pharmacology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0273230026002382?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0273230026002382?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T22:32:14Z","timestamp":1791325934000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0273230026002382"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2027,1]]},"references-count":30,"alternative-id":["S0273230026002382"],"URL":"https:\/\/doi.org\/10.1016\/j.yrtph.2026.106265","relation":{},"ISSN":["0273-2300"],"issn-type":[{"value":"0273-2300","type":"print"}],"subject":[],"published":{"date-parts":[[2027,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Biological-safety-by-design for bioresorbable intravascular drug-delivery implants: Operationalizing ISO 10993-1:2025 across device, degradation, and payload states","name":"articletitle","label":"Article Title"},{"value":"Regulatory Toxicology and Pharmacology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.yrtph.2026.106265","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 The Authors. Published by Elsevier Inc.","name":"copyright","label":"Copyright"}],"article-number":"106265"}}