{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,27]],"date-time":"2026-03-27T18:22:59Z","timestamp":1774635779951,"version":"3.50.1"},"reference-count":29,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2025,8,1]],"date-time":"2025-08-01T00:00:00Z","timestamp":1754006400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,8,1]],"date-time":"2025-08-01T00:00:00Z","timestamp":1754006400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2023,12,4]],"date-time":"2023-12-04T00:00:00Z","timestamp":1701648000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Zeitschrift f\u00fcr Medizinische Physik"],"published-print":{"date-parts":[[2025,8]]},"DOI":"10.1016\/j.zemedi.2023.12.002","type":"journal-article","created":{"date-parts":[[2024,1,5]],"date-time":"2024-01-05T03:36:08Z","timestamp":1704425768000},"page":"282-291","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":2,"title":["Evaluation of RADIANCE Monte Carlo algorithm for treatment planning in electron based Intraoperative Radiotherapy (IOERT)"],"prefix":"10.1016","volume":"35","author":[{"ORCID":"https:\/\/orcid.org\/0009-0000-9368-2167","authenticated-orcid":false,"given":"Charoula","family":"Iliaskou","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Giulio","family":"Rossi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5701-8947","authenticated-orcid":false,"given":"Ilias","family":"Sachpazidis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vasilios","family":"Boronikolas","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0074-3328","authenticated-orcid":false,"given":"Mark","family":"Gainey","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4220-9083","authenticated-orcid":false,"given":"Dimos","family":"Baltas","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"issue":"3","key":"10.1016\/j.zemedi.2023.12.002_b0005","doi-asserted-by":"crossref","first-page":"289","DOI":"10.1097\/00000658-198409000-00006","article-title":"Intraoperative electron beam irradiation for patients with unresectable pancreatic carcinoma","volume":"200","author":"Shipley","year":"1984","journal-title":"Ann Surg"},{"key":"10.1016\/j.zemedi.2023.12.002_b0010","doi-asserted-by":"crossref","first-page":"S226","DOI":"10.1093\/annonc\/10.suppl_4.S226","article-title":"Studies of intraoperative radiotherapy in carcinoma of the pancreas","volume":"10","author":"Sindelar","year":"1999","journal-title":"Ann Oncol"},{"key":"10.1016\/j.zemedi.2023.12.002_b0015","first-page":"91","article-title":"ESTRO IORT Task Force\/ACROP recommendations for intraoperative radiation therapy in borderline-resected pancreatic cancer","volume":"23","author":"Calvo","year":"2020","journal-title":"Clin Transl Radiat Oncol"},{"key":"10.1016\/j.zemedi.2023.12.002_b0020","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1016\/j.radonc.2020.03.040","article-title":"ESTRO IORT Task Force\/ACROP recommendations for intraoperative radiation therapy in unresected pancreatic cancer","volume":"148","author":"Calvo","year":"2020","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.zemedi.2023.12.002_b0025","first-page":"29","article-title":"ESTRO\/ACROP IORT recommendations for intraoperative radiation therapy in primary locally advanced rectal cancer","volume":"25","author":"Calvo","year":"2020","journal-title":"Clin Transl Radiat Oncol"},{"key":"10.1016\/j.zemedi.2023.12.002_b0030","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1016\/j.radonc.2020.07.019","article-title":"Intraoperative radiation therapy (IORT) for soft tissue sarcoma \u2013 ESTRO IORT Task Force\/ACROP recommendations","volume":"150","author":"Roeder","year":"2020","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.zemedi.2023.12.002_b0035","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1016\/j.radonc.2020.04.059","article-title":"ESTRO IORT Task Force\/ACROP recommendations for intraoperative radiation therapy with electrons (IOERT) in breast cancer","volume":"149","author":"Fastner","year":"2020","journal-title":"Radiother Oncol"},{"issue":"5","key":"10.1016\/j.zemedi.2023.12.002_b0040","doi-asserted-by":"crossref","first-page":"1476","DOI":"10.1118\/1.2194447","article-title":"Intraoperative radiation therapy using mobile electron linear accelerators: Report of AAPM Radiation Therapy Committee Task Group No. 72","volume":"33","author":"Beddar","year":"2006","journal-title":"Med Phys"},{"issue":"5","key":"10.1016\/j.zemedi.2023.12.002_b0045","doi-asserted-by":"crossref","first-page":"700","DOI":"10.1016\/S0001-2092(06)61769-9","article-title":"Mobile linear accelerators for intraoperative radiation therapy","volume":"74","author":"Beddar","year":"2001","journal-title":"Aorn j"},{"issue":"1","key":"10.1016\/j.zemedi.2023.12.002_b0050","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1186\/s13014-016-0754-z","article-title":"Present state and issues in IORT Physics","volume":"12","author":"Hensley","year":"2017","journal-title":"Radiation Oncol"},{"issue":"2","key":"10.1016\/j.zemedi.2023.12.002_b0055","first-page":"196","article-title":"RADIANCE\u2014a planning software for intra-operative radiation therapy","volume":"4","author":"Valdivieso-Casique","year":"2015","journal-title":"Transl Cancer Res"},{"issue":"8","key":"10.1016\/j.zemedi.2023.12.002_b0060","doi-asserted-by":"crossref","first-page":"2263","DOI":"10.1088\/0031-9155\/45\/8\/315","article-title":"DPM, a fast, accurate Monte Carlo code optimized for photon and electron radiotherapy treatment planning dose calculations","volume":"45","author":"Sempau","year":"2000","journal-title":"Phys Med Biol"},{"issue":"23","key":"10.1016\/j.zemedi.2023.12.002_b0065","doi-asserted-by":"crossref","first-page":"7159","DOI":"10.1088\/0031-9155\/59\/23\/7159","article-title":"Feasibility assessment of the interactive use of a Monte Carlo algorithm in treatment planning for intraoperative electron radiation therapy","volume":"59","author":"Guerra","year":"2014","journal-title":"Phys Med Biol"},{"issue":"1","key":"10.1016\/j.zemedi.2023.12.002_b0070","doi-asserted-by":"crossref","first-page":"230","DOI":"10.1002\/acm2.12027","article-title":"Commissioning, clinical implementation, and performance of the Mobetron 2000 for intraoperative radiation therapy","volume":"18","author":"Wootton","year":"2017","journal-title":"J Appl Clin Med Phys"},{"key":"10.1016\/j.zemedi.2023.12.002_b0075","unstructured":"Kawrakow RD, Mainegra-Hing E, Tessier F, Townson RW, Walters BRB. EGSnrc toolkit for Monte Carlo simulation of ionizing radiation transport; 2000. https:\/\/doi.org\/10.4224\/40001303."},{"key":"10.1016\/j.zemedi.2023.12.002_b0080","doi-asserted-by":"crossref","unstructured":"D. 6800-2:2020-08. Procedures of dosimetry with probe-type detectors for photon and electron radiation \u2013 Part 2: Ionization chamber dosimetry of high energy photon and electron radiation; 2020. https:\/\/doi.org\/10.31030\/3152276.","DOI":"10.31030\/3152276"},{"key":"10.1016\/j.zemedi.2023.12.002_b0085","article-title":"Phase space determination from measured dose data for intraoperative electron radiation therapy","volume":"375","author":"Herranz","year":"2014","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.zemedi.2023.12.002_b0090","article-title":"Advanced design of radiotherapy equipment : IORT and small animal irradiators","author":"Villa Abaunza","year":"2022","journal-title":"Doctoral dissertation, Universidad Complutense de Madrid, Facultad de Ciencias F\u00edsicas"},{"issue":"11","key":"10.1016\/j.zemedi.2023.12.002_b0095","doi-asserted-by":"crossref","first-page":"5887","DOI":"10.1118\/1.3643029","article-title":"A PENELOPE-based system for the automated Monte Carlo simulation of clinacs and voxelized geometries\u2014application to far-from-axis fields","volume":"38","author":"Sempau","year":"2011","journal-title":"Med Phys"},{"key":"10.1016\/j.zemedi.2023.12.002_b0100","doi-asserted-by":"crossref","first-page":"e1","DOI":"10.1016\/j.ejmp.2020.06.021","article-title":"Beam modeling and beam model commissioning for Monte Carlo dose calculation-based radiation therapy treatment planning: Report of AAPM Task Group 157","volume":"47","author":"Ma","year":"2020","journal-title":"Med Phys"},{"key":"10.1016\/j.zemedi.2023.12.002_b0105","unstructured":"https:\/\/github.com\/mwgeurts\/gamma [accessed]."},{"key":"10.1016\/j.zemedi.2023.12.002_b0110","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1088\/0031-9155\/41\/1\/009","article-title":"The calibration of CT Hounsfield units for radiotherapy treatment planning","volume":"41","author":"Uwe Schneider","year":"1996","journal-title":"Phys Med Biol"},{"issue":"7","key":"10.1016\/j.zemedi.2023.12.002_b0115","doi-asserted-by":"crossref","first-page":"1579","DOI":"10.1118\/1.599024","article-title":"Photon dose calculation of a three-dimensional treatment planning system compared to the Monte Carlo code BEAM","volume":"27","author":"Francescon","year":"2000","journal-title":"Med Phys"},{"key":"10.1016\/j.zemedi.2023.12.002_b0120","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1016\/j.ejmp.2018.12.037","article-title":"3D Monte Carlo dosimetry of intraoperative electron radiation therapy (IOERT)","volume":"57","author":"Alhamada","year":"2019","journal-title":"Phys Med"},{"issue":"1","key":"10.1016\/j.zemedi.2023.12.002_b0125","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1016\/j.ejmp.2012.06.005","article-title":"Validation of a commercial TPS based on the VMC++ Monte Carlo code for electron beams: Commissioning and dosimetric comparison with EGSnrc in homogeneous and heterogeneous phantoms","volume":"30","author":"Ferretti","year":"2014","journal-title":"Phys Med"},{"issue":"3","key":"10.1016\/j.zemedi.2023.12.002_b0130","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1002\/acm2.12836","article-title":"Modeling the head of PRIMUS linear accelerator for electron-mode at 10 MeV for different applicators","volume":"21","author":"Negm","year":"2020","journal-title":"J Appl Clin Med Phys"},{"issue":"22","key":"10.1016\/j.zemedi.2023.12.002_b0135","doi-asserted-by":"crossref","first-page":"4019","DOI":"10.1088\/0031-9155\/47\/22\/308","article-title":"Influence of initial electron beam characteristics on Monte Carlo calculated absorbed dose distributions for linear accelerator electron beams","volume":"47","author":"Peter","year":"2002","journal-title":"Phys Med Biol"},{"issue":"20","key":"10.1016\/j.zemedi.2023.12.002_b0140","doi-asserted-by":"crossref","first-page":"6151","DOI":"10.1088\/0031-9155\/54\/20\/008","article-title":"The accuracy of EGSnrc, Geant4 and PENELOPE Monte Carlo systems for the simulation of electron scatter in external beam radiotherapy","volume":"54","author":"Faddegon","year":"2009","journal-title":"Phys Med Biol"},{"issue":"9","key":"10.1016\/j.zemedi.2023.12.002_b0145","doi-asserted-by":"crossref","first-page":"4186","DOI":"10.1118\/1.2969070","article-title":"Accelerator beam data commissioning equipment and procedures: Report of the TG-106 of the Therapy Physics Committee of the AAPM","volume":"35","author":"Das","year":"2008","journal-title":"Med Phys"}],"container-title":["Zeitschrift f\u00fcr Medizinische Physik"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0939388923001496?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0939388923001496?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,12,18]],"date-time":"2025-12-18T14:25:24Z","timestamp":1766067924000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0939388923001496"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,8]]},"references-count":29,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2025,8]]}},"alternative-id":["S0939388923001496"],"URL":"https:\/\/doi.org\/10.1016\/j.zemedi.2023.12.002","relation":{},"ISSN":["0939-3889"],"issn-type":[{"value":"0939-3889","type":"print"}],"subject":[],"published":{"date-parts":[[2025,8]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Evaluation of RADIANCE Monte Carlo algorithm for treatment planning in electron based Intraoperative Radiotherapy (IOERT)","name":"articletitle","label":"Article Title"},{"value":"Zeitschrift f\u00fcr Medizinische Physik","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.zemedi.2023.12.002","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2023 The Author(s). Published by Elsevier GmbH on behalf of DGMP, \u00d6GMP and SSRMP.","name":"copyright","label":"Copyright"}]}}