{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,23]],"date-time":"2026-06-23T15:48:41Z","timestamp":1782229721855,"version":"3.54.5"},"reference-count":45,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T00:00:00Z","timestamp":1777593600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T00:00:00Z","timestamp":1777593600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2025,4,11]],"date-time":"2025-04-11T00:00:00Z","timestamp":1744329600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100002347","name":"Federal Ministry of Education and Research Bonn Office","doi-asserted-by":"publisher","award":["01EC1005B"],"award-info":[{"award-number":["01EC1005B"]}],"id":[{"id":"10.13039\/501100002347","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Zeitschrift f\u00fcr Medizinische Physik"],"published-print":{"date-parts":[[2026,5]]},"DOI":"10.1016\/j.zemedi.2025.04.002","type":"journal-article","created":{"date-parts":[[2025,5,2]],"date-time":"2025-05-02T08:05:02Z","timestamp":1746173102000},"page":"226-237","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Standardization of bone mineral density and microstructure from high-resolution CT-scans of the spine in a multicenter setting"],"prefix":"10.1016","volume":"36","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9010-713X","authenticated-orcid":false,"given":"Jaime A.","family":"Pe\u00f1a","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Reinhard","family":"Barkmann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3117-1569","authenticated-orcid":false,"given":"Stefan","family":"Reinhold","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5595-5205","authenticated-orcid":false,"given":"Timo","family":"Damm","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tobias","family":"Fricke","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jan","family":"Bastgen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Felix","family":"Thomsen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Claus-C.","family":"Gl\u00fcer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.zemedi.2025.04.002_b0005","doi-asserted-by":"crossref","unstructured":"NIH Consensus Development Panel on Osteoporosis Prevention, Diagnosis, and Therapy. Osteoporosis prevention, diagnosis, and therapy. JAMA 2001;285:785\u201395. DOI: 10.1001\/jama.285.6.785.","DOI":"10.1001\/jama.285.6.785"},{"key":"10.1016\/j.zemedi.2025.04.002_b0010","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1093\/ndt\/gfaa192","article-title":"European Consensus Statement on the diagnosis and management of osteoporosis in chronic kidney disease stages G4\u2013G5D","volume":"36","author":"Evenepoel","year":"2021","journal-title":"Nephrology Dial Transplant"},{"key":"10.1016\/j.zemedi.2025.04.002_b0015","unstructured":"IOF. Epidemiology of osteoporosis and fragility fractures | International Osteoporosis Foundation n.d. https:\/\/www.osteoporosis.foundation\/facts-statistics\/epidemiology-of-osteoporosis-and-fragility-fractures#ref_1 (accessed May 28, 2024)."},{"key":"10.1016\/j.zemedi.2025.04.002_b0020","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1016\/j.jocd.2007.12.010","article-title":"Clinical use of quantitative computed tomography and peripheral quantitative computed tomography in the management of osteoporosis in adults: the 2007 ISCD Official Positions","volume":"11","author":"Engelke","year":"2008","journal-title":"J Clin Densit"},{"key":"10.1016\/j.zemedi.2025.04.002_b0025","doi-asserted-by":"crossref","first-page":"568","DOI":"10.1016\/j.bone.2012.10.036","article-title":"High resolution quantitative computed tomography-based assessment of trabecular microstructure and strength estimates by finite-element analysis of the spine, but not DXA, reflects vertebral fracture status in men with glucocorticoid-induced osteoporosis","volume":"52","author":"Graeff","year":"2013","journal-title":"Bone"},{"key":"10.1016\/j.zemedi.2025.04.002_b0030","doi-asserted-by":"crossref","first-page":"178","DOI":"10.1016\/j.jot.2015.08.006","article-title":"Quantitative computed tomography and opportunistic bone density screening by dual use of computed tomography scans","volume":"3","author":"Brett","year":"2015","journal-title":"J Orthopaedic Transl"},{"key":"10.1016\/j.zemedi.2025.04.002_b0035","doi-asserted-by":"crossref","first-page":"552","DOI":"10.1007\/s00223-024-01303-3","article-title":"Long-term reproducibility of BMD-measurements with clinical QCT using simultaneous and asynchronous calibration methods and different measurement and reconstruction protocols","volume":"115","author":"Du Mont","year":"2024","journal-title":"Calcif Tissue Int"},{"key":"10.1016\/j.zemedi.2025.04.002_b0040","doi-asserted-by":"crossref","first-page":"1225","DOI":"10.1016\/j.medengphy.2014.06.010","article-title":"Inter-scanner differences in in vivo QCT measurements of the density and strength of the proximal femur remain after correction with anthropomorphic standardization phantoms","volume":"36","author":"Carpenter","year":"2014","journal-title":"Med Eng Phys"},{"key":"10.1016\/j.zemedi.2025.04.002_b0045","doi-asserted-by":"crossref","first-page":"5123","DOI":"10.1088\/0031-9155\/55\/17\/015","article-title":"Interphantom and interscanner variations for Hounsfield units\u2014establishment of reference values for HU in a commercial QA phantom","volume":"55","author":"Sande","year":"2010","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.zemedi.2025.04.002_b0050","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1016\/j.jocd.2021.02.004","article-title":"Accuracy, linearity and precision of spine QCT vBMD phantom measurements for different brands of CT scanner: a multicentre study","volume":"25","author":"Zhao","year":"2022","journal-title":"J Clin Densitom"},{"key":"10.1016\/j.zemedi.2025.04.002_b0055","doi-asserted-by":"crossref","DOI":"10.1088\/2057-1976\/aad66a","article-title":"The effect of different CT scanners, scan parameters and scanning setup on Hounsfield units and calibrated bone density: a phantom study","volume":"4","author":"Free","year":"2018","journal-title":"Biomed Phys Eng Express"},{"key":"10.1016\/j.zemedi.2025.04.002_b0060","doi-asserted-by":"crossref","unstructured":"Shuhart CR, Yeap SS, Anderson PA, Jankowski LG, Lewiecki EM, Morse LR, et al. Executive summary of the 2019 ISCD position development conference on monitoring treatment, DXA Cross-calibration and Least Significant Change, Spinal Cord Injury, Peri-prosthetic and Orthopedic Bone Health, Transgender Medicine, and Pediatrics. J Clin Densit 2019;22:453\u201371. DOI: 10.1016\/j.jocd.2019.07.001.","DOI":"10.1016\/j.jocd.2019.07.001"},{"key":"10.1016\/j.zemedi.2025.04.002_b0065","doi-asserted-by":"crossref","first-page":"174","DOI":"10.1007\/BF02106097","article-title":"European semi-anthropomorphic spine phantom for the calibration of bone densitometers: assessment of precision, stability and accuracy the European quantitation of osteoporosis study group","volume":"5","author":"Pearson","year":"1995","journal-title":"Osteoporosis Int"},{"key":"10.1016\/j.zemedi.2025.04.002_b0070","doi-asserted-by":"crossref","first-page":"1503","DOI":"10.1002\/jbmr.5650091002","article-title":"Universal standardization for dual X\u2010ray absorptiometry: Patient and phantom cross\u2010calibration results","volume":"9","author":"Genant","year":"1994","journal-title":"J Bone Mineral Res"},{"key":"10.1016\/j.zemedi.2025.04.002_b0075","doi-asserted-by":"crossref","unstructured":"Reinhold S, Damm T, Huber L, Andresen R, Barkmann R, Gl\u00fcer C-C, et al. An Analysis by Synthesis Approach for Automatic Vertebral Shape Identification in Clinical QCT. In: Brox T, Bruhn A, Fritz M, editors. Pattern Recognition, vol. 11269, Cham: Springer International Publishing; 2019, p. 73\u201388. DOI: 10.1007\/978-3-030-12939-2_6.","DOI":"10.1007\/978-3-030-12939-2_6"},{"key":"10.1016\/j.zemedi.2025.04.002_b0080","series-title":"Bone strength surrogate markers: comprehensive assessment of osteoporosis and osteoporosis treatment in vivo using high-resolution computed tomography","author":"Graeff","year":"2011"},{"key":"10.1016\/j.zemedi.2025.04.002_b0085","doi-asserted-by":"crossref","first-page":"194","DOI":"10.1016\/j.bone.2018.08.024","article-title":"Improved accuracy in the assessment of vertebral cortical thickness by quantitative computed tomography using the Iterative Convolution OptimizatioN (ICON) method","volume":"120","author":"Damm","year":"2019","journal-title":"Bone"},{"key":"10.1016\/j.zemedi.2025.04.002_b0090","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1046\/j.1365-2818.1997.1340694.x","article-title":"A new method for the model\u2010independent assessment of thickness in three\u2010dimensional images","volume":"185","author":"Hildebrand","year":"1997","journal-title":"J Microscopy"},{"key":"10.1016\/j.zemedi.2025.04.002_b0095","doi-asserted-by":"crossref","unstructured":"Griffith JF, Adams JE, Genant HK. Diagnosis and Classification of Vertebral Fracture. In: Rosen CJ, editor. Primer on the metabolic bone diseases and disorders of mineral metabolism, Ames, USA: John Wiley & Sons, Inc.; 2013, p. 317\u201335. DOI: 10.1002\/9781118453926.ch37.","DOI":"10.1002\/9781118453926.ch37"},{"key":"10.1016\/j.zemedi.2025.04.002_b0100","series-title":"A language and environment for statistical computing","author":"R Core Team","year":"2020"},{"key":"10.1016\/j.zemedi.2025.04.002_b0105","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1055\/s-2006-927278","article-title":"Statistische Verfahren zum Vergleich zweier Messmethoden und zur Kalibrierung: Konkordanz-, Korrelations- und Regressionsanalyse am Beispiel der Augeninnendruckmessung","volume":"224","author":"Koch","year":"2007","journal-title":"Klin Monatsbl Augenheilkd"},{"key":"10.1016\/j.zemedi.2025.04.002_b0110","doi-asserted-by":"crossref","first-page":"4174","DOI":"10.1118\/1.4950874","article-title":"Bone-marrow densitometry: assessment of marrow space of human vertebrae by single energy high resolution-quantitative computed tomography: bone-marrow densitometry by CT","volume":"43","author":"Pe\u00f1a","year":"2016","journal-title":"Med Phys"},{"key":"10.1016\/j.zemedi.2025.04.002_b0115","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1016\/S8756-3282(98)00159-8","article-title":"Calibration of trabecular bone structure measurements of in vivo three-dimensional peripheral quantitative computed tomography with 28-\u03bcm-resolution microcomputed tomography","volume":"24","author":"Laib","year":"1999","journal-title":"Bone"},{"key":"10.1016\/j.zemedi.2025.04.002_b0120","doi-asserted-by":"crossref","first-page":"1607","DOI":"10.1007\/s00198-020-05438-5","article-title":"Guidelines for the assessment of bone density and microarchitecture in vivo using high-resolution peripheral quantitative computed tomography","volume":"31","author":"Whittier","year":"2020","journal-title":"Osteoporos Int"},{"key":"10.1016\/j.zemedi.2025.04.002_b0125","doi-asserted-by":"crossref","first-page":"931","DOI":"10.1016\/j.bone.2011.07.021","article-title":"Deriving tissue density and elastic modulus from microCT bone scans","volume":"49","author":"Wagner","year":"2011","journal-title":"Bone"},{"key":"10.1016\/j.zemedi.2025.04.002_b0130","doi-asserted-by":"crossref","unstructured":"Reinhold S, Damm T, B\u00fcsse S, Gorb S, Gl\u00fcer C-C, Koch R. An Analysis by Synthesis Method that Allows Accurate Spatial Modeling of Thickness of Cortical Bone from Clinical QCT. In: Martel AL, Abolmaesumi P, Stoyanov D, Mateus D, Zuluaga MA, Zhou SK, et al., editors. Medical Image Computing and Computer Assisted Intervention \u2013 MICCAI 2020, vol. 12266, Cham: Springer International Publishing; 2020, p. 641\u201351. DOI: 10.1007\/978-3-030-59725-2_62.","DOI":"10.1007\/978-3-030-59725-2_62"},{"key":"10.1016\/j.zemedi.2025.04.002_b0135","doi-asserted-by":"crossref","first-page":"361","DOI":"10.14444\/6049","article-title":"Differences in trabecular bone, cortical shell, and endplate microstructure across the lumbar spine","volume":"13","author":"Palepu","year":"2019","journal-title":"Int J Spine Surg"},{"key":"10.1016\/j.zemedi.2025.04.002_b0140","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1016\/j.jbspin.2005.03.023","article-title":"Antero\u2013postero differences in cortical thickness and cortical porosity of T12 to L5 vertebral bodies","volume":"73","author":"Fazzalari","year":"2006","journal-title":"Joint Bone Spine"},{"key":"10.1016\/j.zemedi.2025.04.002_b0145","doi-asserted-by":"crossref","first-page":"236","DOI":"10.1002\/mp.12632","article-title":"Quantitative imaging of peripheral trabecular bone microarchitecture using MDCT","volume":"45","author":"Chen","year":"2018","journal-title":"Med Phys"},{"key":"10.1016\/j.zemedi.2025.04.002_b0150","doi-asserted-by":"crossref","first-page":"224","DOI":"10.1097\/00003086-198505000-00026","article-title":"Assessment of metabolic bone diseases by quantitative computed tomography","author":"Richardson","year":"1985","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.zemedi.2025.04.002_b0155","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1002\/jbmr.2924","article-title":"Assessment of bone fragility in patients with multiple myeloma using QCT-based finite element modeling","volume":"32","author":"Campbell","year":"2017","journal-title":"J Bone Miner Res"},{"key":"10.1016\/j.zemedi.2025.04.002_b0160","doi-asserted-by":"crossref","first-page":"1672","DOI":"10.1359\/jbmr.090416","article-title":"Improvements in vertebral body strength under teriparatide treatment assessed in vivo by finite element analysis: results from the EUROFORS study","volume":"24","author":"Graeff","year":"2009","journal-title":"J Bone Mineral Res"},{"key":"10.1016\/j.zemedi.2025.04.002_b0165","doi-asserted-by":"crossref","first-page":"1355","DOI":"10.1002\/jbmr.1870","article-title":"Comparative effects of teriparatide and risedronate in glucocorticoid\u2010induced osteoporosis in men: 18\u2010month results of the EuroGIOPs trial","volume":"28","author":"Gl\u00fcer","year":"2013","journal-title":"J Bone Miner Res"},{"key":"10.1016\/j.zemedi.2025.04.002_b0170","doi-asserted-by":"crossref","first-page":"415","DOI":"10.1002\/jbmr.3919","article-title":"Clinical in vivo assessment of bone microarchitecture with CT scanners: an enduring challenge","volume":"35","author":"Tran","year":"2020","journal-title":"J Bone Miner Res"},{"key":"10.1016\/j.zemedi.2025.04.002_b0175","doi-asserted-by":"crossref","DOI":"10.1016\/j.bone.2020.115653","article-title":"Quantification of 3D microstructural parameters of trabecular bone is affected by the analysis software","volume":"142","author":"Mys","year":"2021","journal-title":"Bone"},{"key":"10.1016\/j.zemedi.2025.04.002_b0180","doi-asserted-by":"crossref","first-page":"1023","DOI":"10.1097\/00004728-198911000-00015","article-title":"Impact of marrow fat on accuracy of quantitative CT","volume":"13","author":"Gl\u00fcer","year":"1989","journal-title":"J Comput Assist Tomogr"},{"key":"10.1016\/j.zemedi.2025.04.002_b0185","doi-asserted-by":"crossref","first-page":"456","DOI":"10.1016\/j.bone.2007.10.021","article-title":"Bone mineralization density distribution in health and disease","volume":"42","author":"Roschger","year":"2008","journal-title":"Bone"},{"key":"10.1016\/j.zemedi.2025.04.002_b0190","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1016\/j.bone.2017.03.049","article-title":"Validation of cortical bone mineral density distribution using micro-computed tomography","volume":"99","author":"Mashiatulla","year":"2017","journal-title":"Bone"},{"key":"10.1016\/j.zemedi.2025.04.002_b0195","unstructured":"Thomsen F. Medical 3D image processing applied to computed tomography and magnetic resonance imaging 2017. DOI: 10.13140\/RG.2.2.10998.80966."},{"key":"10.1016\/j.zemedi.2025.04.002_b0200","series-title":"Medical Imaging 2023: Computer-Aided Diagnosis","first-page":"52","article-title":"CT-HARMONICA: physics-based CT harmonization for reliable lung density quantification","author":"Sotoudeh-Paima","year":"2023"},{"key":"10.1016\/j.zemedi.2025.04.002_b0205","doi-asserted-by":"crossref","DOI":"10.1016\/j.compmedimag.2020.101816","article-title":"Noise reduction using novel loss functions to compute tissue mineral density and trabecular bone volume fraction on low resolution QCT","volume":"86","author":"Thomsen","year":"2020","journal-title":"Comput Med Imag Graphics"},{"key":"10.1016\/j.zemedi.2025.04.002_b0210","doi-asserted-by":"crossref","first-page":"836","DOI":"10.1002\/mp.15430","article-title":"Performance of a deep learning\u2010based CT image denoising method: generalizability over dose, reconstruction kernel, and slice thickness","volume":"49","author":"Zeng","year":"2022","journal-title":"Med Phys"},{"key":"10.1016\/j.zemedi.2025.04.002_b0215","series-title":"Medical Imaging 2024: Image Processing","first-page":"45","article-title":"Inter-vendor harmonization of CT reconstruction kernels using unpaired image translation","author":"Krishnan","year":"2024"},{"key":"10.1016\/j.zemedi.2025.04.002_b0220","doi-asserted-by":"crossref","DOI":"10.1093\/bjrai\/ubae012","article-title":"Clinical applications of generative artificial intelligence in radiology: image translation, synthesis, and text generation","volume":"1","author":"Zhong","year":"2024","journal-title":"BJR|Artif Intelligence"},{"key":"10.1016\/j.zemedi.2025.04.002_bib221","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1016\/j.zemedi.2022.04.001","article-title":"Dose-efficient assessment of trabecular microstructure using ultra-high-resolution photon-counting CT","volume":"32","author":"Pe\u00f1a","year":"2022","journal-title":"Zeitschrift F\u00fcr Medizinische Physik"}],"container-title":["Zeitschrift f\u00fcr Medizinische Physik"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0939388925000716?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0939388925000716?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,6,23]],"date-time":"2026-06-23T15:24:25Z","timestamp":1782228265000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0939388925000716"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5]]},"references-count":45,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2026,5]]}},"alternative-id":["S0939388925000716"],"URL":"https:\/\/doi.org\/10.1016\/j.zemedi.2025.04.002","relation":{},"ISSN":["0939-3889"],"issn-type":[{"value":"0939-3889","type":"print"}],"subject":[],"published":{"date-parts":[[2026,5]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Standardization of bone mineral density and microstructure from high-resolution CT-scans of the spine in a multicenter setting","name":"articletitle","label":"Article Title"},{"value":"Zeitschrift f\u00fcr Medizinische Physik","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.zemedi.2025.04.002","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 The Author(s). Published by Elsevier GmbH on behalf of DGMP, \u00d6GMP and SSRMP.","name":"copyright","label":"Copyright"}]}}