{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,21]],"date-time":"2026-10-21T03:57:36Z","timestamp":1792555056542,"version":"4.5.0"},"reference-count":18,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,4,1]],"date-time":"2026-04-01T00:00:00Z","timestamp":1775001600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,4,1]],"date-time":"2026-04-01T00:00:00Z","timestamp":1775001600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,4,17]],"date-time":"2026-04-17T00:00:00Z","timestamp":1776384000000},"content-version":"vor","delay-in-days":16,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Zeitschrift f\u00fcr Medizinische Physik"],"published-print":{"date-parts":[[2026,4]]},"DOI":"10.1016\/j.zemedi.2026.04.002","type":"journal-article","created":{"date-parts":[[2026,4,27]],"date-time":"2026-04-27T03:25:28Z","timestamp":1777260328000},"update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":2,"title":["Error detection sensitivity and operational efficiency of phantom-based and phantom-less patient-specific quality assurance in proton therapy"],"prefix":"10.1016","author":[{"ORCID":"https:\/\/orcid.org\/0009-0007-4019-9439","authenticated-orcid":false,"given":"Lukas Cornelius","family":"Wolter","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yazeed","family":"Ghannam","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kenneth","family":"Poels","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefan","family":"Menkel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3988-4272","authenticated-orcid":false,"given":"Fabian","family":"Hennings","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kevin","family":"Souris","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Theresa","family":"Lenk","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8178-3144","authenticated-orcid":false,"given":"Kristin","family":"St\u00fctzer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4261-4214","authenticated-orcid":false,"given":"Christian","family":"Richter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.zemedi.2026.04.002_b0005","doi-asserted-by":"crossref","first-page":"1165","DOI":"10.1016\/j.ijrobp.2015.04.031","article-title":"Identification of patient benefit from proton therapy for advanced head and neck cancer patients based on individual and subgroup normal tissue complication probability analysis","volume":"92","author":"Jakobi","year":"2015","journal-title":"Int J Radiation Oncology*Biology*Physics"},{"key":"10.1016\/j.zemedi.2026.04.002_b0010","doi-asserted-by":"crossref","DOI":"10.1259\/bjr.20150195","article-title":"Intensity modulated proton therapy","volume":"88","author":"Kooy","year":"2015","journal-title":"Br J Radiol"},{"key":"10.1016\/j.zemedi.2026.04.002_b0015","doi-asserted-by":"crossref","first-page":"e678","DOI":"10.1002\/mp.13622","article-title":"AAPM task group 224: Comprehensive proton therapy machine quality assurance","volume":"46","author":"Arjomandy","year":"2019","journal-title":"Med Phys"},{"key":"10.1016\/j.zemedi.2026.04.002_b0020","doi-asserted-by":"crossref","first-page":"631","DOI":"10.3390\/cancers7020631","article-title":"Towards effective and efficient patient-specific quality assurance for spot scanning proton therapy","volume":"7","author":"Zhu","year":"2015","journal-title":"Cancers (Basel)"},{"key":"10.1016\/j.zemedi.2026.04.002_b0025","doi-asserted-by":"crossref","DOI":"10.1002\/mp.12810","article-title":"Tolerance limits and methodologies for IMRT measurement-based verification QA: Recommendations of AAPM Task Group No. 218","volume":"45","author":"Miften","year":"2018","journal-title":"Med Phys"},{"key":"10.1016\/j.zemedi.2026.04.002_b0030","doi-asserted-by":"crossref","first-page":"1700","DOI":"10.1118\/1.4943377","article-title":"Fast multipurpose Monte Carlo simulation for proton therapy using multi\u2010 and many\u2010core CPU architectures","volume":"43","author":"Souris","year":"2016","journal-title":"Med Phys"},{"key":"10.1016\/j.zemedi.2026.04.002_b0035","doi-asserted-by":"crossref","first-page":"747","DOI":"10.1016\/j.ijrobp.2020.03.036","article-title":"Daily Adaptive Proton Therapy: Is it Appropriate to Use Analytical Dose Calculations for Plan Adaption?","volume":"107","author":"Nenoff","year":"2020","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.zemedi.2026.04.002_b0040","doi-asserted-by":"crossref","DOI":"10.1259\/bjr.20190594","article-title":"Online daily adaptive proton therapy","volume":"93","author":"Albertini","year":"2020","journal-title":"Br J Radiol"},{"key":"10.1016\/j.zemedi.2026.04.002_b0045","doi-asserted-by":"crossref","first-page":"514","DOI":"10.1016\/j.radonc.2017.09.037","article-title":"Treatment log files as a tool to identify treatment plan sensitivity to inaccuracies in scanned proton beam delivery","volume":"125","author":"Belosi","year":"2017","journal-title":"Radiotherapy and Oncology"},{"key":"10.1016\/j.zemedi.2026.04.002_b0050","article-title":"Use of treatment log files in spot scanning proton therapy as part of patient-specific quality assurance","volume":"40","author":"Li","year":"2013","journal-title":"Med Phys"},{"key":"10.1016\/j.zemedi.2026.04.002_b0055","doi-asserted-by":"crossref","DOI":"10.1088\/1361-6560\/ab9f5e","article-title":"Update on yesterday\u2019s dose\u2014Use of delivery log-files for daily adaptive proton therapy (DAPT)","volume":"65","author":"Matter","year":"2020","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.zemedi.2026.04.002_b0060","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1016\/j.ejmp.2019.12.018","article-title":"Platform for automatic patient quality assurance via Monte Carlo simulations in proton therapy","volume":"70","author":"Guterres Marmitt","year":"2020","journal-title":"Phys Med"},{"key":"10.1016\/j.zemedi.2026.04.002_b0065","doi-asserted-by":"crossref","DOI":"10.1088\/1361-6560\/ad7cbd","article-title":"First clinical implementation of a highly efficient daily online adapted proton therapy (DAPT) workflow","volume":"69","author":"Albertini","year":"2024","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.zemedi.2026.04.002_b0070","doi-asserted-by":"crossref","DOI":"10.1002\/mp.14868","article-title":"Report of Task Group 201 of the American Association of Physicists in Medicine: Quality management of external beam therapy data transfer","volume":"48","author":"Siochi","year":"2021","journal-title":"Med Phys"},{"key":"10.1016\/j.zemedi.2026.04.002_b0075","doi-asserted-by":"crossref","DOI":"10.1002\/mp.17637","article-title":"Validity of one\u2010time phantomless patient\u2010specific quality assurance in proton therapy with regard to the reproducibility of beam delivery","author":"Wolter","year":"2025","journal-title":"Med Phys"},{"key":"10.1016\/j.zemedi.2026.04.002_b0080","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/1748-717X-8-127","article-title":"Application of failure mode and effects analysis to treatment planning in scanned proton beam radiotherapy","volume":"8","author":"Cantone","year":"2013","journal-title":"Radiat Oncol"},{"key":"10.1016\/j.zemedi.2026.04.002_b0085","doi-asserted-by":"crossref","DOI":"10.1088\/1361-6560\/aae2f4","article-title":"Alternatives to patient specific verification measurements in proton therapy: a comparative experimental study with intentional errors","volume":"63","author":"Matter","year":"2018","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.zemedi.2026.04.002_b0090","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1002\/mp.13246","article-title":"Automation of routine elements for spot\u2010scanning proton patient\u2010specific quality assurance","volume":"46","author":"Hernandez Morales","year":"2019","journal-title":"Med Phys"}],"container-title":["Zeitschrift f\u00fcr Medizinische Physik"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S093938892600053X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S093938892600053X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,4,27]],"date-time":"2026-04-27T03:25:31Z","timestamp":1777260331000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S093938892600053X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4]]},"references-count":18,"alternative-id":["S093938892600053X"],"URL":"https:\/\/doi.org\/10.1016\/j.zemedi.2026.04.002","relation":{},"ISSN":["0939-3889"],"issn-type":[{"value":"0939-3889","type":"print"}],"subject":[],"published":{"date-parts":[[2026,4]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Error detection sensitivity and operational efficiency of phantom-based and phantom-less patient-specific quality assurance in proton therapy","name":"articletitle","label":"Article Title"},{"value":"Zeitschrift f\u00fcr Medizinische Physik","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.zemedi.2026.04.002","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 The Author(s). Published by Elsevier GmbH on behalf of DGMP, \u00d6GMP and SSRMP.","name":"copyright","label":"Copyright"}]}}