{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,30]],"date-time":"2026-05-30T03:10:30Z","timestamp":1780110630158,"version":"3.54.0"},"reference-count":5,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[1994,10,1]],"date-time":"1994-10-01T00:00:00Z","timestamp":780969600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[1994,10,1]],"date-time":"1994-10-01T00:00:00Z","timestamp":780969600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["ajo.com","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["American Journal of Ophthalmology"],"published-print":{"date-parts":[[1994,10]]},"DOI":"10.1016\/s0002-9394(14)75813-1","type":"journal-article","created":{"date-parts":[[2014,9,26]],"date-time":"2014-09-26T06:11:16Z","timestamp":1411711876000},"page":"533-535","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":34,"title":["Transient Lens Changes After Diode Laser Retinal Photoablation for Retinopathy of Prematurity"],"prefix":"10.1016","volume":"118","author":[{"suffix":"JR.","given":"Antonio","family":"Capone","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Arlene V.","family":"Drack","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/S0002-9394(14)75813-1_bib359","doi-asserted-by":"crossref","first-page":"444","DOI":"10.1016\/S0002-9394(14)71402-3","article-title":"Diode-laser photocoagulation for zone 1 threshold retinopathy of prematurity","volume":"116","author":"Capone","year":"1993","journal-title":"Am. J. Ophthalmol."},{"key":"10.1016\/S0002-9394(14)75813-1_bib360","doi-asserted-by":"crossref","first-page":"583","DOI":"10.1016\/S0002-9394(14)74733-6","article-title":"Transient punctate lenticular opacities as a complication of argon laser photoablation in an infant with retinopathy of prematurity","volume":"113","author":"Drack","year":"1992","journal-title":"Am. J. Ophthalmol."},{"key":"10.1016\/S0002-9394(14)75813-1_bib361","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1016\/S0002-9394(14)73088-0","article-title":"Argon laser-induced cataract in an infant with retinopathy of prematurity","volume":"117","author":"Pogrebniak","year":"1994","journal-title":"Am. J. Ophthalmol."},{"key":"10.1016\/S0002-9394(14)75813-1_bib362","doi-asserted-by":"crossref","first-page":"1068","DOI":"10.1001\/archopht.1982.01030040046003","article-title":"Photocoagulation-induced lens opacity","volume":"100","author":"Lakhanpal","year":"1982","journal-title":"Arch. Ophthalmol."},{"key":"10.1016\/S0002-9394(14)75813-1_bib363","doi-asserted-by":"crossref","first-page":"314","DOI":"10.1016\/S0022-3476(73)80180-5","article-title":"Transient cataract in low-birth-weight infants","volume":"82","author":"Alden","year":"1973","journal-title":"J. Pediatr."}],"container-title":["American Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0002939414758131?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0002939414758131?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,11]],"date-time":"2025-09-11T13:26:41Z","timestamp":1757597201000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0002939414758131"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1994,10]]},"references-count":5,"journal-issue":{"issue":"4","published-print":{"date-parts":[[1994,10]]}},"alternative-id":["S0002939414758131"],"URL":"https:\/\/doi.org\/10.1016\/s0002-9394(14)75813-1","relation":{},"ISSN":["0002-9394"],"issn-type":[{"value":"0002-9394","type":"print"}],"subject":[],"published":{"date-parts":[[1994,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Transient Lens Changes After Diode Laser Retinal Photoablation for Retinopathy of Prematurity","name":"articletitle","label":"Article Title"},{"value":"American Journal of Ophthalmology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/S0002-9394(14)75813-1","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"simple-article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 1994 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}