{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,21]],"date-time":"2025-10-21T00:43:35Z","timestamp":1761007415628,"version":"build-2065373602"},"reference-count":29,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2016,5,17]],"date-time":"2016-05-17T00:00:00Z","timestamp":1463443200000},"content-version":"vor","delay-in-days":6652,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["aao-hnsfjournals.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Otolaryngol.--head neck surg."],"published-print":{"date-parts":[[1998,3]]},"abstract":"<jats:p>The auditory brain stem implant has been used effectively to provide hearing sensations to individuals deafened by bilateral auditory nerve tumors (neurofibromatosis type 2). During tumor removal, the auditory brain stem implant is implanted into the lateral recess of the fourth ventricle by a translabyrinthine approach and is intended to stimulate auditory neurons of the cochlear nucleus complex. A new eight\u2010electrode multichannel auditory brain stem implant was developed and evaluated in 20 patients who had at least 3\u00a0months' experience with the device. Mild nonauditory sensations (primarily tingling in the head or torso) were encountered in some instances but could be managed by changing the stimulus characteristics or excluding electrodes. Testing of perceptual performance indicated significant benefit from the device for communication purposes, including sound\u2010only sentence recognition scores in three patients ranging from 49% to 58% and ability to converse on the telephone. These results indicate that significant auditory benefit can be derived from direct multichannel electrical stimulation of the auditory portion of the human brain stem.<\/jats:p>","DOI":"10.1016\/s0194-59989870304-3","type":"journal-article","created":{"date-parts":[[2022,9,28]],"date-time":"2022-09-28T13:24:09Z","timestamp":1664371449000},"page":"291-303","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":11,"title":["The Multichannel Auditory Brain Stem Implant: Performance in Twenty Patients"],"prefix":"10.1002","volume":"118","author":[{"given":"Steven R.","family":"Otto","sequence":"first","affiliation":[{"name":"House Ear Institute, the House Ear Clinic Los Angeles California"},{"name":"Cochlear Corporation Englewood Colorado"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Robert V.","family":"Shannon","sequence":"additional","affiliation":[{"name":"House Ear Institute, the House Ear Clinic Los Angeles California"},{"name":"Cochlear Corporation Englewood Colorado"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Derald E.","family":"Brackmann","sequence":"additional","affiliation":[{"name":"House Ear Institute, the House Ear Clinic Los Angeles California"},{"name":"Cochlear Corporation Englewood Colorado"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"William E.","family":"Hitselberger","sequence":"additional","affiliation":[{"name":"House Ear Institute, the House Ear Clinic Los Angeles California"},{"name":"Cochlear Corporation Englewood Colorado"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Steven","family":"Staller","sequence":"additional","affiliation":[{"name":"House Ear Institute, the House Ear Clinic Los Angeles California"},{"name":"Cochlear Corporation Englewood Colorado"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christine","family":"Menapace","sequence":"additional","affiliation":[{"name":"House Ear Institute, the House Ear Clinic Los Angeles California"},{"name":"Cochlear Corporation Englewood Colorado"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2016,5,17]]},"reference":[{"key":"e_1_2_5_2_1","doi-asserted-by":"publisher","DOI":"10.1177\/019459988409200111"},{"key":"e_1_2_5_3_1","doi-asserted-by":"publisher","DOI":"10.1682\/JRRD.1987.07.0009"},{"key":"e_1_2_5_4_1","doi-asserted-by":"publisher","DOI":"10.1177\/019459989310800602"},{"key":"e_1_2_5_5_1","doi-asserted-by":"publisher","DOI":"10.1177\/019459989310800603"},{"key":"e_1_2_5_6_1","first-page":"175","volume-title":"Advances in cochlear implants.","author":"Shannon RV","year":"1994"},{"key":"e_1_2_5_7_1","first-page":"36","article-title":"Multichannel auditory brainstem implant: case studies comparing fitting strategies and results","volume":"104","author":"Otto SR","year":"1994","journal-title":"Ann Otol Rhinol Laryngol Suppl"},{"key":"e_1_2_5_8_1","doi-asserted-by":"publisher","DOI":"10.1001\/jama.1993.03510190072029"},{"key":"e_1_2_5_9_1","doi-asserted-by":"publisher","DOI":"10.1038\/329246a0"},{"key":"e_1_2_5_10_1","first-page":"393","article-title":"Case of tumors in the skull, dura mater and brain","volume":"18","author":"Wishart JH","year":"1822","journal-title":"Edinburgh Med Surg J"},{"key":"e_1_2_5_11_1","doi-asserted-by":"publisher","DOI":"10.1001\/archotol.1980.00790360007003"},{"key":"e_1_2_5_12_1","first-page":"9","article-title":"Clinical trials of the auditory brainstem implant","volume":"7","author":"Staller S","year":"1995","journal-title":"Audiol Today"},{"key":"e_1_2_5_13_1","first-page":"33","article-title":"Intraoperative electrophysiologic monitoring to assist placement of auditory brainstem implant","volume":"104","author":"Waring MD","year":"1995","journal-title":"Ann Otol Rhinol Laryngol Suppl"},{"key":"e_1_2_5_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/0168-5597(95)00022-K"},{"key":"e_1_2_5_15_1","first-page":"99","volume-title":"Cochlear prostheses.","author":"Patrick JF","year":"1990"},{"key":"e_1_2_5_16_1","doi-asserted-by":"publisher","DOI":"10.1109\/10.126616"},{"key":"e_1_2_5_17_1","first-page":"724","article-title":"Evaluation of MRI compatibility of the modified Nucleus multichannel auditory brainstem and cochlear implants","volume":"17","author":"Heller JW","year":"1996","journal-title":"Am J Otol"},{"key":"e_1_2_5_18_1","doi-asserted-by":"publisher","DOI":"10.1121\/1.402826"},{"volume-title":"Technical reference manual.","year":"1995","key":"e_1_2_5_19_1"},{"key":"e_1_2_5_20_1","doi-asserted-by":"publisher","DOI":"10.1097\/00003446-199102000-00002"},{"key":"e_1_2_5_21_1","doi-asserted-by":"publisher","DOI":"10.1097\/00003446-199310000-00006"},{"key":"e_1_2_5_22_1","first-page":"15","article-title":"Evaluation of a new spectral peak coding strategy for the Nucleus 22 channel cochlear implant system","volume":"15","author":"Skinner M","year":"1994","journal-title":"Am J Otol"},{"key":"e_1_2_5_23_1","doi-asserted-by":"publisher","DOI":"10.1044\/jshd.4102.256"},{"volume-title":"Sound Effects Recognition Test (SERT).","year":"1977","author":"Finitzo\u2010Hieber T","key":"e_1_2_5_24_1"},{"volume-title":"Development of a new children's test of speech discrimination. St.","year":"1980","author":"Elliott LL","key":"e_1_2_5_25_1"},{"volume-title":"Iowa Audiovisual Speech Perception Laser Videodisc.","year":"1987","author":"Tyler RS","key":"e_1_2_5_26_1"},{"volume-title":"CUNY Topic Related Sentence Test Laser Videodisk.","year":"1988","author":"Boothroyd A","key":"e_1_2_5_27_1"},{"key":"e_1_2_5_28_1","doi-asserted-by":"publisher","DOI":"10.1016\/0378-5955(89)90110-X"},{"key":"e_1_2_5_29_1","doi-asserted-by":"publisher","DOI":"10.1016\/0378-5955(90)90173-M"},{"key":"e_1_2_5_30_1","doi-asserted-by":"publisher","DOI":"10.1126\/science.270.5234.303"}],"container-title":["Otolaryngology\u2013Head and Neck Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/S0194-59989870304-3","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1016\/S0194-59989870304-3","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/aao-hnsfjournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1016\/S0194-59989870304-3","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,20]],"date-time":"2025-10-20T12:56:45Z","timestamp":1760965005000},"score":1,"resource":{"primary":{"URL":"https:\/\/aao-hnsfjournals.onlinelibrary.wiley.com\/doi\/10.1016\/S0194-59989870304-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1998,3]]},"references-count":29,"journal-issue":{"issue":"3","published-print":{"date-parts":[[1998,3]]}},"alternative-id":["10.1016\/S0194-59989870304-3"],"URL":"https:\/\/doi.org\/10.1016\/s0194-59989870304-3","archive":["Portico"],"relation":{},"ISSN":["0194-5998","1097-6817"],"issn-type":[{"type":"print","value":"0194-5998"},{"type":"electronic","value":"1097-6817"}],"subject":[],"published":{"date-parts":[[1998,3]]},"assertion":[{"value":"2016-05-17","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}