{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T00:53:24Z","timestamp":1791852804115,"version":"4.3.4"},"reference-count":26,"publisher":"Cambridge University Press (CUP)","issue":"3","license":[{"start":{"date-parts":[[2015,7,21]],"date-time":"2015-07-21T00:00:00Z","timestamp":1437436800000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/www.cambridge.org\/core\/terms"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Robotica"],"published-print":{"date-parts":[[2017,3]]},"abstract":"<jats:title>SUMMARY<\/jats:title><jats:p>An underactuated mechanism is presented as a new finger design for improving grasp adaptability of LARM Hand fingers. Underactuation is discussed as a feasible solution through several design structures for finger adaptability to shape and size of objects to be grasped. The proposed underactuated solution for a new LARM finger is characterized through simulation results in ADAMS environment for operation feasibility and performance.<\/jats:p>","DOI":"10.1017\/s0263574715000648","type":"journal-article","created":{"date-parts":[[2015,7,21]],"date-time":"2015-07-21T07:21:06Z","timestamp":1437463266000},"page":"483-497","source":"Crossref","is-referenced-by-count":29,"title":["Design and simulation of an underactuated finger mechanism for LARM Hand"],"prefix":"10.1017","volume":"35","author":[{"given":"M.","family":"Ceccarelli","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.","family":"Zottola","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"56","published-online":{"date-parts":[[2015,7,21]]},"reference":[{"key":"S0263574715000648_ref7","unstructured":"C. M. Gosselin and T. Lalibert\u00e8 , Underactuated mechanical finger with return actuation, US patent 5762390, June (1998)."},{"key":"S0263574715000648_ref1","doi-asserted-by":"publisher","DOI":"10.1007\/978-1-4471-4664-3"},{"key":"S0263574715000648_ref22","first-page":"39","article-title":"Design of LARM hand: Problems and solutions","volume":"10","author":"Carbone","year":"2008","journal-title":"J. Control Eng. Appl. Inform."},{"key":"S0263574715000648_ref24","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1017\/S0263574705002018","article-title":"Design and tests of a three finger hand with 1-DOF articulated fingers","volume":"24","author":"Rodriguez","year":"2006","journal-title":"Robotica"},{"key":"S0263574715000648_ref2","doi-asserted-by":"publisher","DOI":"10.1007\/978-1-4020-2110-7"},{"key":"S0263574715000648_ref9","first-page":"417","article-title":"Linkage under-actuated humanoid robotic hand with control of grasping force","volume":"2","author":"Zhang","year":"2010","journal-title":"Inform. Control, Autom. Robot. (CAR)"},{"key":"S0263574715000648_ref13","doi-asserted-by":"publisher","DOI":"10.1142\/S0219843611002538"},{"key":"S0263574715000648_ref18","unstructured":"J. F. Mullen , Mechanical Hand, US patent 3694021, September (1972)."},{"key":"S0263574715000648_ref6","first-page":"897","article-title":"Optimal design of driving mechanism in a 1-DOF anthropomorphic finger","volume":"41","author":"Ceccarelli","year":"2005","journal-title":"Mech. Mach. Theory"},{"key":"S0263574715000648_ref23","doi-asserted-by":"publisher","DOI":"10.1016\/S0094-114X(01)00035-0"},{"key":"S0263574715000648_ref25","unstructured":"M. Zottola , Master's Thesis \u2013 Design of an underactuated LARM finger mechanism for robotic hand, University of Cassino and South Latium, Cassino (2013)."},{"key":"S0263574715000648_ref12","doi-asserted-by":"publisher","DOI":"10.1109\/TRO.2009.2017138"},{"key":"S0263574715000648_ref8","doi-asserted-by":"crossref","unstructured":"M. C. Carrozza , G. Cappiello , G. Stellin , F. Zaccone , F. Vecchi , S. Micera and P. Dario , \u201cA Cosmetic Prosthetic Hand with Tendon Driven Under-Actuated Mechanism and Compliant Joints: Ongoing Research and Preliminary Results,\u201d Proceedings of the 2005 IEEE International Conference on Robotics and Automation (ICRA), Barcelona (Apr. 2005) pp. 2661\u20132666.","DOI":"10.1109\/ROBOT.2005.1570515"},{"key":"S0263574715000648_ref17","unstructured":"J. D. Crisman , C. Kanojia and I. Zeid I, Robot arm end-effectors, US patent 5570920 (1996)."},{"key":"S0263574715000648_ref16","first-page":"1","article-title":"Underactuation in robotic grasping hands","volume":"4","author":"Lalibert\u00e8","year":"2002","journal-title":"Mach. Robot. Control"},{"key":"S0263574715000648_ref15","volume-title":"Compliant Mechanisms","author":"Howell","year":"2001"},{"key":"S0263574715000648_ref10","doi-asserted-by":"publisher","DOI":"10.1080\/15397730802713397"},{"key":"S0263574715000648_ref5","doi-asserted-by":"publisher","DOI":"10.1109\/70.897777"},{"key":"S0263574715000648_ref26","doi-asserted-by":"crossref","unstructured":"L. Birglen and C. M. Gosselin , \u201cOn the Force Capability of Underactuated Fingers,\u201d Proceedings of the 2003 IEEE International Conference on Robotics and Automation (ICRA), Taipei, Vol. 1, (Sep. 2003) pp. 1139\u20131145.","DOI":"10.1109\/ROBOT.2003.1241746"},{"key":"S0263574715000648_ref14","doi-asserted-by":"crossref","unstructured":"M. Ceccarelli , C. Tavolieri and Z. Lu , \u201cDesign Considerations for Underactuated Grasp with a one D.O.F. Anthropomorphic Finger Mechanism,\u201d International Conference on Intelligent Robots and Systems IROS 2006, Beijing (Oct. 2006) pp. 1611\u20131616.","DOI":"10.1109\/IROS.2006.282051"},{"key":"S0263574715000648_ref20","doi-asserted-by":"crossref","unstructured":"R. Cabas , L. M. Cabas and C. Balaguer , \u201cOptimized Design of the Underactuated Robotic Hand,\u201d Proceedings of the 2006 IEEE International Conference on Robotics and Automation (ICRA), Orlando, Florida (May 2006) pp. 982\u2013987.","DOI":"10.1109\/ROBOT.2006.1641837"},{"key":"S0263574715000648_ref4","volume-title":"Gripping Systems","author":"Staretu","year":"2011"},{"key":"S0263574715000648_ref11","doi-asserted-by":"crossref","first-page":"332","DOI":"10.1007\/s11465-011-0229-8","article-title":"Analysis and optimal design of an underactuated finger mechanism for LARM hand","volume":"6","author":"Yao","year":"2011","journal-title":"Frontiers Mech. Eng."},{"key":"S0263574715000648_ref19","unstructured":"S. Bhatti , \u201cDesign of a multiple finger prosthetic hand with a passive adaptive grasp system,\u201d EE 4BI6 Electrical Engineering Biomedical Capstones, Paper 28, Hamilton, Canada (2010)."},{"key":"S0263574715000648_ref21","doi-asserted-by":"crossref","unstructured":"J. Zhao , L. Jiang , S. Shi , H. Cai , H. Liu and G. Hirzinger , \u201cA Five-Fingered Underactuated Prosthetic Hand System,\u201d Proceedings of the 2006 IEEE International Conference on Mechatronics and Automation, Luoyang (Jun. 2006) pp. 1453\u20131458.","DOI":"10.1109\/ICMA.2006.257843"},{"key":"S0263574715000648_ref3","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-540-30301-5"}],"container-title":["Robotica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cambridge.org\/core\/services\/aop-cambridge-core\/content\/view\/S0263574715000648","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,9,5]],"date-time":"2020-09-05T08:50:33Z","timestamp":1599295833000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cambridge.org\/core\/product\/identifier\/S0263574715000648\/type\/journal_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,7,21]]},"references-count":26,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2017,3]]}},"alternative-id":["S0263574715000648"],"URL":"https:\/\/doi.org\/10.1017\/s0263574715000648","relation":{},"ISSN":["0263-5747","1469-8668"],"issn-type":[{"value":"0263-5747","type":"print"},{"value":"1469-8668","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,7,21]]}}}