{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,19]],"date-time":"2026-10-19T06:56:36Z","timestamp":1792392996673,"version":"4.4.0"},"reference-count":40,"publisher":"Cambridge University Press (CUP)","issue":"7","license":[{"start":{"date-parts":[[2016,6,9]],"date-time":"2016-06-09T00:00:00Z","timestamp":1465430400000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/www.cambridge.org\/core\/terms"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Robotica"],"published-print":{"date-parts":[[2017,7]]},"abstract":"<jats:title>SUMMARY<\/jats:title><jats:p>During the past decade, robotics for cochlear implant electrode array insertion has been limited to manipulation assistance. Going beyond manipulation assistance, this paper presents the new concept of<jats:italic>perception augmentation<\/jats:italic>to detect and warn against the<jats:italic>onset<\/jats:italic>of intracochlear electrode array tip folding. This<jats:italic>online<\/jats:italic>failure detection method uses a combination of intraoperative electrode insertion force data and a predictive model of insertion force profile progression as a function of insertion depth. The predictive model uses statistical characterization of insertion force profiles during normal robotic electrode array insertions as well as the history of intra-operative insertion forces. Online detection of onset of tip folding is achieved using the predictive model as an input into a support vector machine classifier. Results show that the detection of tip folding onset can be achieved with an accuracy of 88% despite the use of intra-operative insertion force data representing incomplete insertion. This result is significant because it allows the surgeon or robot to choose a corrective action for preventing intra-cochlear complications.<\/jats:p>","DOI":"10.1017\/s0263574716000333","type":"journal-article","created":{"date-parts":[[2016,6,9]],"date-time":"2016-06-09T10:13:37Z","timestamp":1465467217000},"page":"1598-1615","source":"Crossref","is-referenced-by-count":11,"title":["Robot-assisted perception augmentation for online detection of insertion failure during cochlear implant surgery"],"prefix":"10.1017","volume":"35","author":[{"given":"J.","family":"Pile","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"G. B.","family":"Wanna","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"N.","family":"Simaan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"56","published-online":{"date-parts":[[2016,6,9]]},"reference":[{"key":"S0263574716000333_ref24","doi-asserted-by":"publisher","DOI":"10.1109\/TMECH.2014.2308479"},{"key":"S0263574716000333_ref17","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0b013e318219f6ac"},{"key":"S0263574716000333_ref3","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-642-14075-4_33"},{"key":"S0263574716000333_ref36","doi-asserted-by":"publisher","DOI":"10.1016\/j.heares.2004.11.007"},{"key":"S0263574716000333_ref6","unstructured":"P. A. Bromiley , \u201cProducts and convolutions of Gaussian distributions,\u201d Tech. rep., Medical School, Univ. Manchester, Manchester, UK, Tech. Rep 3, Manchester, UK (2003)."},{"key":"S0263574716000333_ref14","doi-asserted-by":"publisher","DOI":"10.1097\/AUD.0b013e31827e8163"},{"key":"S0263574716000333_ref32","volume-title":"Computational Science and Engineering","author":"Strang","year":"2007"},{"key":"S0263574716000333_ref12","doi-asserted-by":"publisher","DOI":"10.1090\/S0025-5718-96-00759-4"},{"key":"S0263574716000333_ref2","doi-asserted-by":"publisher","DOI":"10.1097\/00005537-200407000-00018"},{"key":"S0263574716000333_ref4","doi-asserted-by":"publisher","DOI":"10.1179\/cim.2001.2.2.135"},{"key":"S0263574716000333_ref23","doi-asserted-by":"crossref","unstructured":"J. Pile , M. Y. Cheung , J. Zhang and N. Simaan , \u201cAlgorithms and design Considerations for Robot Assisted Insertion of Perimodiolar Electrode Arrays,\u201d IEEE International Conference on Robotics and Automation (ICRA'2011), Shanghai, China (2011) pp. 2898\u20132904.","DOI":"10.1109\/ICRA.2011.5979987"},{"key":"S0263574716000333_ref18","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0b013e31821b3c88"},{"key":"S0263574716000333_ref35","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0b013e3182096dc2"},{"key":"S0263574716000333_ref15","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0b013e318238264d"},{"key":"S0263574716000333_ref29","volume-title":"Advances in Kernel Methods: Support Vector Learning","author":"Scholkopf","year":"1999"},{"key":"S0263574716000333_ref34","doi-asserted-by":"publisher","DOI":"10.1002\/lary.24728"},{"key":"S0263574716000333_ref30","doi-asserted-by":"publisher","DOI":"10.1162\/089976600300015565"},{"key":"S0263574716000333_ref16","doi-asserted-by":"crossref","unstructured":"H. H. King , R. Donlin and B. Hannaford , \u201cPerceptual thresholds for single vs. multi-finger haptic interaction,\u201d Proceedings of the IEEE Haptics Symposium, IEEE, Waltham, MA USA (2010) pp. 95\u201399.","DOI":"10.1109\/HAPTIC.2010.5444670"},{"key":"S0263574716000333_ref11","doi-asserted-by":"publisher","DOI":"10.1097\/00005537-200303000-00005"},{"key":"S0263574716000333_ref37","doi-asserted-by":"crossref","unstructured":"J. Zhang , S. Bhattacharyya and N. Simaan , \u201cModel and Parameter Identification of Friction During Robotic Insertion of Cochlear-Implant Electrode Arrays,\u201d Proceedings of the IEEE International Conference on Robotics and Automation (Kobe, Japan, 2009a) 3859\u20133864.","DOI":"10.1109\/ROBOT.2009.5152738"},{"key":"S0263574716000333_ref25","doi-asserted-by":"crossref","unstructured":"J. Pile and N. Simaan , \u201cCharacterization of Friction and Speed effects and Methods for Detection of Cochlear Implant Electrode Tip Fold-Over,\u201d Proceedings of the IEEE International Conference on Robotics and Automation, IEEE, Karlsruhe, Germany (May 2013) pp. 4409\u20134414.","DOI":"10.1109\/ICRA.2013.6631202"},{"key":"S0263574716000333_ref28","doi-asserted-by":"publisher","DOI":"10.1097\/01.mlg.0000167993.05007.35"},{"key":"S0263574716000333_ref38","doi-asserted-by":"publisher","DOI":"10.1115\/1.3039513"},{"key":"S0263574716000333_ref9","first-page":"859","article-title":"Improved and simplified methods for specifying positions of the electrode bands of a cochlear implant array","volume":"17","author":"Cohen","year":"1996","journal-title":"Am. J. Otology"},{"key":"S0263574716000333_ref20","doi-asserted-by":"crossref","first-page":"1092","DOI":"10.1097\/MAO.0b013e31825f24de","article-title":"Friction force measurement during cochlear implant insertion: Application to a force-controlled insertion tool design","volume":"33","author":"Miroir","year":"2012","journal-title":"Otology Neurotology"},{"key":"S0263574716000333_ref22","doi-asserted-by":"publisher","DOI":"10.1109\/TBME.2011.2160262"},{"key":"S0263574716000333_ref19","doi-asserted-by":"publisher","DOI":"10.3109\/00016480902998281"},{"key":"S0263574716000333_ref21","unstructured":"NIH Medical Arts, accessed 2011. http:\/\/www.medarts.nih.gov\/."},{"key":"S0263574716000333_ref13","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0b013e318184f492"},{"key":"S0263574716000333_ref26","doi-asserted-by":"crossref","unstructured":"J. Pile , G. B. Wanna and N. Simaan , \u201cForce-Based Flexible Path Plans for Robotic Electrode Insertion,\u201d Proceedings of the IEEE International Conference on Robotics and Automation, IEEE, Hong Kong (2014b) pp. 297\u2013303.","DOI":"10.1109\/ICRA.2014.6906625"},{"key":"S0263574716000333_ref39","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0b013e3181e7117e"},{"key":"S0263574716000333_ref33","doi-asserted-by":"publisher","DOI":"10.1109\/TBME.2007.891937"},{"key":"S0263574716000333_ref10","doi-asserted-by":"publisher","DOI":"10.1016\/j.otot.2010.10.003"},{"key":"S0263574716000333_ref5","doi-asserted-by":"publisher","DOI":"10.1179\/1754762811Y0000000007"},{"key":"S0263574716000333_ref40","doi-asserted-by":"crossref","unstructured":"J. Zhang , K. Xu , N. Simaan and S. Manolidis , \u201cA Pilot Study of Robot-Assisted Cochlear Implant Surgery Using Steerable Electrode Arrays,\u201d Medical Image Computing and Computer-Assisted Intervention : MICCAI .\u00a0.\u00a0. International Conference on Medical Image Computing and Computer-Assisted Intervention vol. 9 (Pt 1) (Copenhagen, Denmark, Jan. 2006) 33\u201340.","DOI":"10.1007\/11866565_5"},{"key":"S0263574716000333_ref27","doi-asserted-by":"crossref","first-page":"638","DOI":"10.1177\/0194599813519747","article-title":"Forces and trauma associated with minimally invasive image-guided cochlear implantation","volume":"150","author":"Rohani","year":"2014","journal-title":"Otolaryngology"},{"key":"S0263574716000333_ref1","doi-asserted-by":"publisher","DOI":"10.1159\/000081887"},{"key":"S0263574716000333_ref7","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0b013e3182204526"},{"key":"S0263574716000333_ref31","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0b013e3181f2ebc3"},{"key":"S0263574716000333_ref8","unstructured":"J. R. Clark , Toward Improved Cochlear Implant Insertion Using Magnetic Guidance. Masters' Thesis, University of Utah (2011)."}],"container-title":["Robotica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cambridge.org\/core\/services\/aop-cambridge-core\/content\/view\/S0263574716000333","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,7,1]],"date-time":"2022-07-01T09:53:55Z","timestamp":1656669235000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cambridge.org\/core\/product\/identifier\/S0263574716000333\/type\/journal_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,6,9]]},"references-count":40,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2017,7]]}},"alternative-id":["S0263574716000333"],"URL":"https:\/\/doi.org\/10.1017\/s0263574716000333","relation":{},"ISSN":["0263-5747","1469-8668"],"issn-type":[{"value":"0263-5747","type":"print"},{"value":"1469-8668","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,6,9]]}}}