{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,2]],"date-time":"2026-05-02T15:10:36Z","timestamp":1777734636656,"version":"3.51.4"},"reference-count":34,"publisher":"Cambridge University Press (CUP)","issue":"4","license":[{"start":{"date-parts":[[2021,8,20]],"date-time":"2021-08-20T00:00:00Z","timestamp":1629417600000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/www.cambridge.org\/core\/terms"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Robotica"],"published-print":{"date-parts":[[2022,4]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Due to increasing demand for rehabilitation and therapy for cerebrovascular diseases, patients require advanced development of medical rehabilitation robots. In our laboratory, we focus on the formation capability of the substitute neural path caused by brain plasticity using the kinesthetic illusion (KI), which is effective for therapies using robots. In KI, people perceive an illusionary limb movement without an actual movement when a vibration stimulus is applied to a limb\u2019s tendons. In previous research, the optimal frequency that induces the maximum KI has a correlation factor of about 0.5 with the tendon\u2019s natural frequency when a human subject is in a state of laxity. However, we do not know whether the above finding can be applied to actual rehabilitation because muscles and tendons are sometimes in tonus during rehabilitation, a state that varies the natural frequency. In this study, we investigate the correlation between the optimal and natural frequencies of tendon by systematically changing their tension to clarify the effects on the illusion induced by the muscle and the tendon when they are in tonus. We identified a negative correlation between the optimal and natural frequencies when they are in tonus, although a positive correlation appeared when they are in laxity. This result suggests that KI\u2019s optimal frequency should be changed based on the degree of the tendon and muscle tonus. Therefore, our present findings provide a suitable vibration frequency that induces KI due to the degree of the tendon and muscle tonus during robot therapies.<\/jats:p>","DOI":"10.1017\/s0263574721001107","type":"journal-article","created":{"date-parts":[[2021,8,20]],"date-time":"2021-08-20T07:02:35Z","timestamp":1629442955000},"page":"1222-1232","source":"Crossref","is-referenced-by-count":6,"title":["Degree of muscle-and-tendon tonus effects on kinesthetic illusion in wrist joints toward advanced rehabilitation robotics"],"prefix":"10.1017","volume":"40","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7540-9810","authenticated-orcid":false,"given":"Hiraku","family":"Komura","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takumu","family":"Kubo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masakazu","family":"Honda","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masahiro","family":"Ohka","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"56","published-online":{"date-parts":[[2021,8,20]]},"reference":[{"key":"S0263574721001107_ref6","doi-asserted-by":"publisher","DOI":"10.1016\/j.jelekin.2008.04.002"},{"key":"S0263574721001107_ref32","doi-asserted-by":"publisher","DOI":"10.1016\/0021-9290(94)00137-S"},{"key":"S0263574721001107_ref13","unstructured":"[13] Motus, Nova , \u201cMotus Hand,\u201d [Online]. https:\/\/motusnova.com\/hand\/. [Accessed 20 May 2021]."},{"key":"S0263574721001107_ref29","doi-asserted-by":"publisher","DOI":"10.1109\/AIM.2019.8868657"},{"key":"S0263574721001107_ref14","unstructured":"[14] CyberGrasp systems, \u201cCyberGrasp,\u201d [Online]. http:\/\/www.cyberglovesystems.com\/cybergrasp. [Accessed 20 May 2021]."},{"key":"S0263574721001107_ref16","unstructured":"[16] Neofect, \u201cNeofect Smart Glove,\u201d [Online]. https:\/\/www.neofect.com\/us\/smart-glove. [Accessed 20 May 2021]."},{"key":"S0263574721001107_ref7","unstructured":"[7] Loureiro, R. C. , Belda-Lois, J. M. , Lima, E. R. , Pons, J. L. , Sanchez-Lacuesta, J. J. and Harwin, W. S. , \u201cUpper Limb Tremor Suppression in ADL via an Orthosis Incorporating a Controllable Double Viscous Beam Actuator,\u201d Proceedings 9th International Conference on Rehabilitation Robotics ICORR, Chicago (2005)."},{"key":"S0263574721001107_ref31","first-page":"69","article-title":"A guide to appropriate use of Correlation coefficient in medical research","volume":"24","author":"Mukaka","year":"2012","journal-title":"Malawi Med. J."},{"key":"S0263574721001107_ref10","doi-asserted-by":"publisher","DOI":"10.1109\/TNSRE.2017.2692520"},{"key":"S0263574721001107_ref34","doi-asserted-by":"publisher","DOI":"10.1589\/jpts.28.419"},{"key":"S0263574721001107_ref24","doi-asserted-by":"publisher","DOI":"10.1007\/s00221-005-0325-2"},{"key":"S0263574721001107_ref26","doi-asserted-by":"publisher","DOI":"10.1152\/jn.00025.2010"},{"key":"S0263574721001107_ref22","doi-asserted-by":"publisher","DOI":"10.1126\/scitranslmed.aao6990"},{"key":"S0263574721001107_ref4","first-page":"361","article-title":"State-of-the-art robotic devices for wrist rehabilitation: Design and control aspects","volume":"50","author":"Hussain","year":"2014","journal-title":"Syst."},{"key":"S0263574721001107_ref20","doi-asserted-by":"publisher","DOI":"10.1177\/0269215515593610"},{"key":"S0263574721001107_ref5","unstructured":"[5] Sasaki, D. , Noritsugu, T. and Takaiwa, M. , \u201cDevelopment of Active Support Splint Driven by Pneumatic Soft Actuator (ASSIST),\u201d Proceedings IEEE International Conference on Robotics and Automation (ICRA), Spain (2005)."},{"key":"S0263574721001107_ref21","doi-asserted-by":"publisher","DOI":"10.1109\/ACCESS.2020.2969789"},{"key":"S0263574721001107_ref28","doi-asserted-by":"publisher","DOI":"10.1109\/MHS.2015.7438265"},{"key":"S0263574721001107_ref17","doi-asserted-by":"publisher","DOI":"10.1186\/s12984-016-0125-x"},{"key":"S0263574721001107_ref11","doi-asserted-by":"publisher","DOI":"10.1017\/S0263574714001490"},{"key":"S0263574721001107_ref33","unstructured":"[33] Yamada, H. and Evan, G. F. , \u201cStrength of Biological Materials,\u201d The Williams and Wilkins Company, (1970)."},{"key":"S0263574721001107_ref18","doi-asserted-by":"publisher","DOI":"10.1523\/JNEUROSCI.19-14-06134.1999"},{"key":"S0263574721001107_ref9","doi-asserted-by":"publisher","DOI":"10.1109\/TNSRE.2018.2853143"},{"key":"S0263574721001107_ref15","doi-asserted-by":"publisher","DOI":"10.1186\/1743-0003-6-28"},{"key":"S0263574721001107_ref2","unstructured":"[2] GBD 2016 Stroke Collaborators, \u201cGlobal, regional, and national burden of stroke, 1990\u20132016: A systematic analysis for the Global Burden of Disease Study 2016,\u201d Lancet Neurol. 48, 439\u2013458 (2019)."},{"key":"S0263574721001107_ref25","doi-asserted-by":"publisher","DOI":"10.1152\/jn.91075.2008"},{"key":"S0263574721001107_ref12","doi-asserted-by":"publisher","DOI":"10.1017\/S0263574719000651"},{"key":"S0263574721001107_ref27","doi-asserted-by":"publisher","DOI":"10.1109\/MHS.2014.7006082"},{"key":"S0263574721001107_ref8","doi-asserted-by":"publisher","DOI":"10.1109\/ICORR.2007.4428434"},{"key":"S0263574721001107_ref23","doi-asserted-by":"publisher","DOI":"10.1007\/BF00239377"},{"key":"S0263574721001107_ref19","doi-asserted-by":"publisher","DOI":"10.1589\/jpts.26.1115"},{"key":"S0263574721001107_ref30","doi-asserted-by":"publisher","DOI":"10.1523\/JNEUROSCI.0683-09.2009"},{"key":"S0263574721001107_ref1","unstructured":"[1] Ministry of Health, Labour and Welfare, \u201cSummary of Patient Survey,\u201d (2017) [Online]. Available: https:\/\/www.mhlw.go.jp\/toukei\/saikin\/hw\/kanja\/17\/index.html. [Accessed 20 May 2021]."},{"key":"S0263574721001107_ref3","doi-asserted-by":"publisher","DOI":"10.1186\/1743-0003-11-3"}],"container-title":["Robotica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cambridge.org\/core\/services\/aop-cambridge-core\/content\/view\/S0263574721001107","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,3,10]],"date-time":"2022-03-10T03:32:41Z","timestamp":1646883161000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cambridge.org\/core\/product\/identifier\/S0263574721001107\/type\/journal_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,8,20]]},"references-count":34,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2022,4]]}},"alternative-id":["S0263574721001107"],"URL":"https:\/\/doi.org\/10.1017\/s0263574721001107","relation":{},"ISSN":["0263-5747","1469-8668"],"issn-type":[{"value":"0263-5747","type":"print"},{"value":"1469-8668","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,8,20]]}}}