{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T20:45:27Z","timestamp":1786999527475,"version":"build-2736575974"},"reference-count":28,"publisher":"Cambridge University Press (CUP)","issue":"10","license":[{"start":{"date-parts":[[2025,10,16]],"date-time":"2025-10-16T00:00:00Z","timestamp":1760572800000},"content-version":"unspecified","delay-in-days":15,"URL":"https:\/\/www.cambridge.org\/core\/terms"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Robotica"],"published-print":{"date-parts":[[2025,10]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>With increasing age, many elderly individuals will not be able to stand normally. To solve this problem, a knee exoskeleton is designed. The knee joint is designed as a variable stiffness structure. It can adjust its stiffness according to the body\u2019s movement state, ensuring precise assistance while also enhancing human comfort. The variable stiffness mechanism consists of an elastic output actuator and a stiffness-adjusting actuator. The elastic output actuator is mainly responsible for the output of the joint torque. The stiffness-adjusting actuator is mainly responsible for adjusting the joint stiffness. These two mechanisms are analysed separately. Based on their relationship with the whole mechanism, a stiffness model of the entire knee joint is established. Experiments are subsequently conducted to evaluate the variable stiffness joint. The stiffness identification experiment indicates that the actual stiffness of the whole knee joint is essentially consistent with the theoretical value. The trajectory tracking experiment demonstrates that the joint exhibits excellent trajectory tracking capability, although stiffness has a certain effect. The exoskeleton assistive effect experiment demonstrates the ability of the exoskeleton to assist in standing. Additionally, the experiment on subjects with exoskeletons of different stiffnesses determines the impact of stiffness on human comfort.<\/jats:p>","DOI":"10.1017\/s0263574725102695","type":"journal-article","created":{"date-parts":[[2025,10,16]],"date-time":"2025-10-16T10:45:47Z","timestamp":1760611547000},"page":"3737-3754","source":"Crossref","is-referenced-by-count":2,"title":["Design of a novel auxiliary standing knee exoskeleton with variable stiffness"],"prefix":"10.1017","volume":"43","author":[{"ORCID":"https:\/\/orcid.org\/0009-0007-6945-7438","authenticated-orcid":false,"given":"Gong","family":"Cheng","sequence":"first","affiliation":[{"name":"South China University of Technology"},{"name":"South China University of Technology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yanjiang","family":"Huang","sequence":"additional","affiliation":[{"name":"South China University of Technology"},{"name":"South China University of Technology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6636-0306","authenticated-orcid":false,"given":"Kai","family":"Wang","sequence":"additional","affiliation":[{"name":"Foshan University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xianmin","family":"Zhang","sequence":"additional","affiliation":[{"name":"South China University of Technology"},{"name":"South China University of Technology"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"56","published-online":{"date-parts":[[2025,10,16]]},"reference":[{"key":"S0263574725102695_ref9","doi-asserted-by":"crossref","unstructured":"[9] Daines, K. , Lemaire, E. D. , Smith, A. and Herbert-Copley, A. , \u201cSit-to-Stand and Stand-to-Sit Crutch Use for Lower Extremity Powered Exoskeletons,\u201d In: 2017 IEEE International Symposium on Robotics and Intelligent Sensors (IRIS), IEEE (2017) pp. 358\u2013363.","DOI":"10.1109\/IRIS.2017.8250148"},{"key":"S0263574725102695_ref6","doi-asserted-by":"publisher","DOI":"10.1017\/S0263574725000220"},{"key":"S0263574725102695_ref4","doi-asserted-by":"publisher","DOI":"10.1017\/S0263574725101781"},{"key":"S0263574725102695_ref19","doi-asserted-by":"publisher","DOI":"10.1109\/TMECH.2017.2704521"},{"key":"S0263574725102695_ref1","doi-asserted-by":"publisher","DOI":"10.3390\/ijerph182211802"},{"key":"S0263574725102695_ref20","doi-asserted-by":"publisher","DOI":"10.1080\/01691864.2016.1154800"},{"key":"S0263574725102695_ref22","doi-asserted-by":"publisher","DOI":"10.1016\/j.mechmachtheory.2018.07.024"},{"key":"S0263574725102695_ref23","doi-asserted-by":"publisher","DOI":"10.1016\/j.mechmachtheory.2021.104716"},{"key":"S0263574725102695_ref27","doi-asserted-by":"publisher","DOI":"10.1109\/TMECH.2020.3032372"},{"key":"S0263574725102695_ref28","doi-asserted-by":"publisher","DOI":"10.1017\/S0263574725000451"},{"key":"S0263574725102695_ref15","doi-asserted-by":"crossref","unstructured":"[15] Kimura, M. , Pham, H. , Kawanishi, M. and Narikiyo, T. , \u201cEMG-Force-Sensorless Power Assist System Control Based on Multi-Class Support Vector Machine,\u201d In: 11th IEEE International Conference on Control & Automation (ICCA), IEEE (2014) pp. 284\u2013289.","DOI":"10.1109\/ICCA.2014.6870933"},{"key":"S0263574725102695_ref16","doi-asserted-by":"crossref","unstructured":"[16] Choi, G. , Lee, D. , Kang, I. and Young, A. J. , \u201cEffect of Assistance Timing in Knee Extensor Muscle Activation During Sit-to-Stand Using a Bilateral Robotic Knee Exoskeleton,\u201d In: 2021 43rd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC), IEEE (2021) pp. 4879\u20134882.","DOI":"10.1109\/EMBC46164.2021.9629965"},{"key":"S0263574725102695_ref18","doi-asserted-by":"crossref","unstructured":"[18] Shepherd, M. K. and Rouse, E. J. , \u201cDesign and Characterization of a Torque-controllable Actuator for Knee Assistance During Sit-to-Stand,\u201d In: 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), IEEE (2016) pp. 2228\u20132231.","DOI":"10.1109\/EMBC.2016.7591172"},{"key":"S0263574725102695_ref7","doi-asserted-by":"publisher","DOI":"10.1017\/S0263574723000693"},{"key":"S0263574725102695_ref3","doi-asserted-by":"crossref","unstructured":"[3] Kim, S.-W. , Song, J. , Suh, S. , Lee, W. and Kang, S. , \u201cDesign and Experiment of a Passive Sit-to-Stand and Walking (STSW) Assistance Device for the Elderly,\u201d In: 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), IEEE (2018) pp. 1781\u20131784.","DOI":"10.1109\/EMBC.2018.8512540"},{"key":"S0263574725102695_ref5","doi-asserted-by":"crossref","unstructured":"[5] Hiyama, T. , Kato, Y. and Inoue, T. , \u201cSit-to-Stand Assistance System Based on Using EMG to Predict Movement,\u201d In: 2017 26th IEEE International Symposium on Robot and Human Interactive Communication (RO-MAN), IEEE (2017) pp. 81\u201387.","DOI":"10.1109\/ROMAN.2017.8172284"},{"key":"S0263574725102695_ref11","doi-asserted-by":"publisher","DOI":"10.1109\/LRA.2022.3148799"},{"key":"S0263574725102695_ref21","doi-asserted-by":"publisher","DOI":"10.1109\/TBME.2012.2207895"},{"key":"S0263574725102695_ref24","first-page":"1","article-title":"Adaptive command filter backstepping sliding mode control for variable stiffness exoskeleton with input saturation constraint","volume":"73","author":"Zhu","year":"2024","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"S0263574725102695_ref26","doi-asserted-by":"publisher","DOI":"10.1109\/TMECH.2021.3063374"},{"key":"S0263574725102695_ref25","doi-asserted-by":"publisher","DOI":"10.1109\/TII.2023.3240749"},{"key":"S0263574725102695_ref8","doi-asserted-by":"publisher","DOI":"10.1109\/TMECH.2018.2799865"},{"key":"S0263574725102695_ref10","doi-asserted-by":"crossref","unstructured":"[10] Sarkisian, S. V. , Gunnell, A. J. , Foreman, K. B. and Lenzi, T. , \u201cKnee Exoskeleton Reduces Muscle Effort and Improves Balance During Sit-to-Stand Transitions After Stroke: A Case Study,\u201d In: 2022 International Conference on Rehabilitation Robotics (ICORR), IEEE (2022) pp. 1\u20136.","DOI":"10.1109\/ICORR55369.2022.9896571"},{"key":"S0263574725102695_ref2","doi-asserted-by":"crossref","unstructured":"[2] Chuy, O. , Hirata, Y. , Wang, Z. and Kosuge, K. , \u201cApproach in Assisting a Sit-to-Stand Movement Using Robotic Walking Support System,\u201d In: 2006 IEEE\/RSJ International Conference on Intelligent Robots and Systems, IEEE (2006) pp. 4343\u20134348.","DOI":"10.1109\/IROS.2006.282007"},{"key":"S0263574725102695_ref14","doi-asserted-by":"publisher","DOI":"10.1016\/j.mechmachtheory.2020.103840"},{"key":"S0263574725102695_ref12","doi-asserted-by":"crossref","unstructured":"[12] Huo, W. , Mohammed, S. , Amirat, Y. and Kong, K. , \u201cActive Impedance Control of a Lower Limb Exoskeleton to Assist Sit-to-Stand Movement,\u201d In: 2016 IEEE international conference on robotics and automation (ICRA), IEEE (2016) pp. 3530\u20133536.","DOI":"10.1109\/ICRA.2016.7487534"},{"key":"S0263574725102695_ref17","doi-asserted-by":"publisher","DOI":"10.1017\/S0263574717000546"},{"key":"S0263574725102695_ref13","doi-asserted-by":"publisher","DOI":"10.1109\/LRA.2022.3145580"}],"container-title":["Robotica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cambridge.org\/core\/services\/aop-cambridge-core\/content\/view\/S0263574725102695","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,18]],"date-time":"2025-11-18T08:27:11Z","timestamp":1763454431000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cambridge.org\/core\/product\/identifier\/S0263574725102695\/type\/journal_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10]]},"references-count":28,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2025,10]]}},"alternative-id":["S0263574725102695"],"URL":"https:\/\/doi.org\/10.1017\/s0263574725102695","relation":{},"ISSN":["0263-5747","1469-8668"],"issn-type":[{"value":"0263-5747","type":"print"},{"value":"1469-8668","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,10]]}}}