{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T01:38:59Z","timestamp":1760146739473},"reference-count":13,"publisher":"Cambridge University Press (CUP)","issue":"7","license":[{"start":{"date-parts":[[2007,6,29]],"date-time":"2007-06-29T00:00:00Z","timestamp":1183075200000},"content-version":"unspecified","delay-in-days":4746,"URL":"https:\/\/www.cambridge.org\/core\/terms"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J. Laryngol. Otol."],"published-print":{"date-parts":[[1994,7]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Intraoperative facial nerve monitoring has become an integral adjunct in facial nerve identification and preservation for patients undergoing cerebellopontine angle surgery. Since the first description of EMG monitoring of facial nerve activity intraoperatively, many systems have been developed. These systems often rely on unilateral monitoring of the facial nerve with auditory feedback to the surgeon, and it is difficult to distinguish between artifact and significant stimulation of the facial nerve.<\/jats:p><jats:p>In this paper, we present the use of a bilateral, multialarm, facial nerve monitoring system that has multiple advantages over previous systems. Furthermore, we review our experience with this bilateral system, comparing a group of 50 monitored patients to a group of 50 unmonitored patients.<\/jats:p>","DOI":"10.1017\/s0022215100127409","type":"journal-article","created":{"date-parts":[[2007,11,30]],"date-time":"2007-11-30T10:16:14Z","timestamp":1196417774000},"page":"551-556","source":"Crossref","is-referenced-by-count":2,"title":["Intraoperative facial nerve monitoring: a description of a unique system"],"prefix":"10.1017","volume":"108","author":[{"given":"Richard J.","family":"Wiet","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"George P.","family":"Bauer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Don","family":"Stewart","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"John J.","family":"Zappia","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"56","published-online":{"date-parts":[[2007,6,29]]},"reference":[{"key":"S0022215100127409_ref007","first-page":"99","volume-title":"Neuromonitoring in Otology and Head and Neck Surgery","author":"Kartush","year":"1991"},{"key":"S0022215100127409_ref001","doi-asserted-by":"publisher","DOI":"10.1227\/00006123-197905000-00007"},{"key":"S0022215100127409_ref008","doi-asserted-by":"publisher","DOI":"10.1177\/019459989110400608"},{"key":"S0022215100127409_ref002","first-page":"1","article-title":"A comparison of facial nerve monitoring systems in cerebellopontine angle surgery","volume":"12","author":"Dickens","year":"1991","journal-title":"American Journal of Otology"},{"key":"S0022215100127409_ref012","first-page":"269","article-title":"Routine intraoperative facial nerve monitoring during otologic surgery","volume":"9","author":"Silverstein","year":"1988","journal-title":"American Journal of Otology"},{"key":"S0022215100127409_ref010","first-page":"55","article-title":"Neurophysiologic intraoperative monitoring: neurophysiologic facial nerve function","volume":"10","author":"Niparko","year":"1989","journal-title":"American Journal of Otology"},{"key":"S0022215100127409_ref004","first-page":"225","volume-title":"Instructional Courses","author":"Harner","year":"1988"},{"key":"S0022215100127409_ref006","doi-asserted-by":"publisher","DOI":"10.1177\/019459988509300202"},{"key":"S0022215100127409_ref011","first-page":"458","article-title":"Facial nerve dissection by use of acoustic (loudspeaker) facial EMG monitoring","volume":"96","author":"Rinney","year":"1986","journal-title":"Otolaryngology-Head and Neck Surgery"},{"key":"S0022215100127409_ref003","doi-asserted-by":"publisher","DOI":"10.1288\/00005537-198601000-00012"},{"key":"S0022215100127409_ref005","doi-asserted-by":"publisher","DOI":"10.1288\/00005537-198802000-00018"},{"key":"S0022215100127409_ref013","doi-asserted-by":"crossref","first-page":"413","DOI":"10.1016\/S0030-6665(20)30994-4","article-title":"Intraoperative monitoring of facial and cochlear nerves during acoustic neuroma surgery","volume":"75","author":"Yingling","year":"1992","journal-title":"Otolaryngologic Clinics of North America"},{"key":"S0022215100127409_ref009","doi-asserted-by":"publisher","DOI":"10.3171\/jns.1984.61.4.0757"}],"container-title":["The Journal of Laryngology &amp; Otology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cambridge.org\/core\/services\/aop-cambridge-core\/content\/view\/S0022215100127409","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,8,29]],"date-time":"2021-08-29T13:06:36Z","timestamp":1630242396000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cambridge.org\/core\/product\/identifier\/S0022215100127409\/type\/journal_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1994,7]]},"references-count":13,"journal-issue":{"issue":"7","published-print":{"date-parts":[[1994,7]]}},"alternative-id":["S0022215100127409"],"URL":"https:\/\/doi.org\/10.1017\/s0022215100127409","relation":{},"ISSN":["0022-2151","1748-5460"],"issn-type":[{"value":"0022-2151","type":"print"},{"value":"1748-5460","type":"electronic"}],"subject":[],"published":{"date-parts":[[1994,7]]}}}