{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,23]],"date-time":"2026-06-23T15:40:51Z","timestamp":1782229251054,"version":"3.54.5"},"reference-count":34,"publisher":"Cambridge University Press (CUP)","issue":"11","license":[{"start":{"date-parts":[[2007,3,26]],"date-time":"2007-03-26T00:00:00Z","timestamp":1174867200000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/www.cambridge.org\/core\/terms"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J. Laryngol. Otol."],"published-print":{"date-parts":[[2007,11]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec id=\"S0022215107006883_sec1\"><jats:title>Introduction:<\/jats:title><jats:p>We aimed to study the influence of age, in normal hearing individuals, on: the masking level difference test, the speech recognition in noise test, the transient evoked otoacoustic emissions test, and the contralateral transient evoked otoacoustic emission suppression test. We also aimed to research the effect of age when using these tests to evaluate the central auditory nervous system.<\/jats:p><\/jats:sec><jats:sec id=\"S0022215107006883_sec2\"><jats:title>Methods:<\/jats:title><jats:p>Transient evoked otoacoustic emissions and contralateral transient evoked otoacoustic emission suppression were measured in all subjects. Subjects also underwent masking level difference and speech recognition in noise tests.<\/jats:p><\/jats:sec><jats:sec id=\"S0022215107006883_sec3\"><jats:title>Results:<\/jats:title><jats:p>We found a decrease in transient evoked otoacoustic emission amplitudes, speech recognition in noise scores and hearing thresholds with age. We also found that higher masking level difference values were associated with lower speech recognition in noise scores and contralateral transient evoked otoacoustic emission suppression values.<\/jats:p><\/jats:sec><jats:sec id=\"S0022215107006883_sec4\"><jats:title>Conclusion:<\/jats:title><jats:p>We conclude that decreasing speech recognition in noise scores are associated with decreasing contralateral transient evoked otoacoustic emission supression values. This effect may be related to medial efferent system dysfunction.<\/jats:p><\/jats:sec>","DOI":"10.1017\/s0022215107006883","type":"journal-article","created":{"date-parts":[[2007,3,26]],"date-time":"2007-03-26T09:55:02Z","timestamp":1174902902000},"page":"1029-1034","source":"Crossref","is-referenced-by-count":21,"title":["Effect of age on speech recognition in noise and on contralateral transient evoked otoacoustic emission suppression"],"prefix":"10.1017","volume":"121","author":[{"given":"S T","family":"Y\u0131lmaz","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"G","family":"Sennaro\u011flu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"L","family":"Sennaro\u011flu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S K","family":"K\u00f6se","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"56","published-online":{"date-parts":[[2007,3,26]]},"reference":[{"key":"S0022215107006883_ref34","volume-title":"Efferent Auditory System, Structure and Function","author":"Sahley","year":"1997"},{"key":"S0022215107006883_ref30","doi-asserted-by":"publisher","DOI":"10.1097\/00005537-199911000-00004"},{"key":"S0022215107006883_ref29","first-page":"12","article-title":"Otoacoustic emissions and the olivocochlear bundle","volume":"45","author":"Musiek","year":"1992","journal-title":"The Hearing Journal"},{"key":"S0022215107006883_ref28","doi-asserted-by":"publisher","DOI":"10.1097\/00005537-200310000-00009"},{"key":"S0022215107006883_ref24","doi-asserted-by":"publisher","DOI":"10.1080\/010503901300007425"},{"key":"S0022215107006883_ref19","doi-asserted-by":"publisher","DOI":"10.3109\/00206090109073127"},{"key":"S0022215107006883_ref16","first-page":"214","article-title":"Nonspeech procedures in central testing","author":"Schoeny","year":"1994","journal-title":"Handbook of Clinical Audiology"},{"key":"S0022215107006883_ref14","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1055\/s-0042-1745583","article-title":"Aging and contralateral suppression effects on transient evoked otoacoustic emissions","volume":"12","author":"Parthasarathy","year":"2001","journal-title":"J Am Acad Audiol"},{"key":"S0022215107006883_ref7","doi-asserted-by":"publisher","DOI":"10.3109\/00206097609071789"},{"key":"S0022215107006883_ref6","doi-asserted-by":"publisher","DOI":"10.1523\/JNEUROSCI.17-23-09331.1997"},{"key":"S0022215107006883_ref4","first-page":"78","article-title":"The medial olivocochlear efferent system in humans: structure and fuction","volume":"28","author":"Maison","year":"1999","journal-title":"Scand Audiol"},{"key":"S0022215107006883_ref2","doi-asserted-by":"publisher","DOI":"10.1121\/1.382104"},{"key":"S0022215107006883_ref9","first-page":"375","volume-title":"Contemporary Perspectives in Hearing Assessment","author":"Baran","year":"1999"},{"key":"S0022215107006883_ref8","first-page":"161","article-title":"Speech understanding in the elderly","volume":"7","author":"Humes","year":"1996","journal-title":"J Am Acad Audiol"},{"key":"S0022215107006883_ref5","first-page":"53","article-title":"Clinical relevance of medial efferent pathways","volume":"28","author":"Veuillet","year":"1999","journal-title":"Scand Audiol"},{"key":"S0022215107006883_ref1","volume-title":"Hearing, Its Physiology and Pathophysiology","author":"M\u00f8ller","year":"2000"},{"key":"S0022215107006883_ref15","doi-asserted-by":"publisher","DOI":"10.1016\/S0378-5955(96)00138-4"},{"key":"S0022215107006883_ref10","first-page":"224","volume-title":"Handbook of Clinical Audiology","author":"Mueller","year":"1994"},{"key":"S0022215107006883_ref13","doi-asserted-by":"publisher","DOI":"10.1097\/00129492-200105000-00013"},{"key":"S0022215107006883_ref22","doi-asserted-by":"publisher","DOI":"10.3109\/01050399109045971"},{"key":"S0022215107006883_ref21","doi-asserted-by":"publisher","DOI":"10.3109\/00016489109127267"},{"key":"S0022215107006883_ref11","volume-title":"Central Auditory Processing Disorders","author":"Bellis","year":"1996"},{"key":"S0022215107006883_ref18","doi-asserted-by":"publisher","DOI":"10.1097\/00003446-200012000-00004"},{"key":"S0022215107006883_ref17","doi-asserted-by":"publisher","DOI":"10.3758\/BF03206169"},{"key":"S0022215107006883_ref27","doi-asserted-by":"publisher","DOI":"10.1016\/0378-5955(94)90248-8"},{"key":"S0022215107006883_ref25","doi-asserted-by":"publisher","DOI":"10.3109\/14992020309090422"},{"key":"S0022215107006883_ref3","first-page":"204","volume-title":"Handbook of Otoacoustic Emissions","author":"Hall","year":"2000"},{"key":"S0022215107006883_ref23","unstructured":"23 F\u0131\u015f\u0131lo\u011flu A , Katz J . The effects of contralateral noise on the perception of pure tones and speech: a study of children with auditory proccessing difficulties and normal controls. XXII International Congress of Audiology, July 3\u20137, Halifax, Nova Scotia, Canada 1994."},{"key":"S0022215107006883_ref26","doi-asserted-by":"publisher","DOI":"10.1159\/000066159"},{"key":"S0022215107006883_ref33","doi-asserted-by":"publisher","DOI":"10.1121\/1.414734"},{"key":"S0022215107006883_ref20","doi-asserted-by":"publisher","DOI":"10.3109\/00206090109073123"},{"key":"S0022215107006883_ref12","doi-asserted-by":"publisher","DOI":"10.3109\/03005364000000018"},{"key":"S0022215107006883_ref31","doi-asserted-by":"publisher","DOI":"10.3109\/00206090009098012"},{"key":"S0022215107006883_ref32","doi-asserted-by":"publisher","DOI":"10.2298\/MPNS0304124K"}],"container-title":["The Journal of Laryngology &amp; Otology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cambridge.org\/core\/services\/aop-cambridge-core\/content\/view\/S0022215107006883","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,11]],"date-time":"2023-05-11T04:59:17Z","timestamp":1683781157000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cambridge.org\/core\/product\/identifier\/S0022215107006883\/type\/journal_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2007,3,26]]},"references-count":34,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2007,11]]}},"alternative-id":["S0022215107006883"],"URL":"https:\/\/doi.org\/10.1017\/s0022215107006883","relation":{},"ISSN":["0022-2151","1748-5460"],"issn-type":[{"value":"0022-2151","type":"print"},{"value":"1748-5460","type":"electronic"}],"subject":[],"published":{"date-parts":[[2007,3,26]]}}}