{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T00:40:45Z","timestamp":1791852045607,"version":"4.3.4"},"reference-count":13,"publisher":"Cambridge University Press (CUP)","issue":"12","license":[{"start":{"date-parts":[[2012,10,26]],"date-time":"2012-10-26T00:00:00Z","timestamp":1351209600000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/www.cambridge.org\/core\/terms"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J. Laryngol. Otol."],"published-print":{"date-parts":[[2012,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec id=\"S0022215112002368_sec1\"><jats:title>Objective:<\/jats:title><jats:p>To determine the best clinical method for identifying peripheral vestibular nystagmus, by comparing eye movement examination with optic fixation, and with fixation removed using Frenzel's glasses, infra-red video-Frenzel's goggles or an ophthalmoscope, with results of electronystagmography.<\/jats:p><\/jats:sec><jats:sec id=\"S0022215112002368_sec2\"><jats:title>Method:<\/jats:title><jats:p>One hundred patients referred for electronystagmography from the audiovestibular medicine clinic at Queen Alexandra Hospital, Portsmouth, were examined immediately before undergoing electronystagmography.<\/jats:p><\/jats:sec><jats:sec id=\"S0022215112002368_sec3\"><jats:title>Results:<\/jats:title><jats:p>Video-Frenzel's goggles were highly effective at detecting peripheral vestibular nystagmus, with a sensitivity of 85 per cent (95 per cent confidence interval, 62.1\u201396.8 per cent) and a specificity of 65 per cent (53.5\u201375.3 per cent), compared with electronystagmography. Ophthalmoscopy had comparable sensitivity to Frenzel's glasses (used in the dark), i.e. 26.3 per cent (9.1\u201351.2 per cent) compared with 31.6 per cent (12.6\u201356.6 per cent), respectively. Frenzel's glasses as normally used in ENT clinics (i.e. in dim lighting) were ineffective, with a sensitivity of just 10 per cent (1.2\u201331.7 per cent).<\/jats:p><\/jats:sec><jats:sec id=\"S0022215112002368_sec4\"><jats:title>Conclusion:<\/jats:title><jats:p>Video-Frenzel's goggles should be used in all clinics with substantial numbers of balance-impaired patients. Traditional Frenzel's glasses have no place in clinical practice unless formal black-out facilities are available.<\/jats:p><\/jats:sec>","DOI":"10.1017\/s0022215112002368","type":"journal-article","created":{"date-parts":[[2012,10,26]],"date-time":"2012-10-26T08:51:03Z","timestamp":1351241463000},"page":"1209-1215","source":"Crossref","is-referenced-by-count":18,"title":["Comparison of techniques for identification of peripheral vestibular nystagmus"],"prefix":"10.1017","volume":"126","author":[{"given":"P D B","family":"West","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Z A","family":"Sheppard","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"E V","family":"King","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"56","published-online":{"date-parts":[[2012,10,26]]},"reference":[{"key":"S0022215112002368_ref4","first-page":"134","article-title":"Caloric nystagmus: ENG in comparison with observation by Frenzel's glasses","volume":"25","author":"Strauss","year":"1979","journal-title":"Adv Otorhinolaryngol"},{"key":"S0022215112002368_ref8","doi-asserted-by":"publisher","DOI":"10.1177\/00034894770865S302"},{"key":"S0022215112002368_ref12","doi-asserted-by":"publisher","DOI":"10.3109\/00016486909124366"},{"key":"S0022215112002368_ref5","doi-asserted-by":"publisher","DOI":"10.1272\/jnms.71.25"},{"key":"S0022215112002368_ref2","doi-asserted-by":"publisher","DOI":"10.1152\/jn.00055.2008"},{"key":"S0022215112002368_ref13","volume-title":"Provision of Adult Balance Services: A Good Practice Guide","year":"2009"},{"key":"S0022215112002368_ref1","doi-asserted-by":"publisher","DOI":"10.1007\/BF00455584"},{"key":"S0022215112002368_ref3","first-page":"89","article-title":"Do Frenzel glasses have a place in the modern electronystagmography laboratory?","volume":"17","author":"Ben-David","year":"1996","journal-title":"Am J Otol"},{"key":"S0022215112002368_ref6","doi-asserted-by":"publisher","DOI":"10.1007\/BF00455860"},{"key":"S0022215112002368_ref7","first-page":"96","article-title":"Clinical examination of labyrinthine-defective patients out of the vertigo attack: sensitivity and specificity of three low-cost methods","volume":"26","author":"Guidetti","year":"2006","journal-title":"Acta Otorhinolaryngol Ital"},{"key":"S0022215112002368_ref9","unstructured":"British Society of Audiology: Recommended procedure: The caloric test. In: http:\/\/www.thebsa.org.uk\/docs\/RecPro\/CTP.pdf [15 February 2012]"},{"key":"S0022215112002368_ref10","first-page":"65","article-title":"Clinical nystagmography. A detailed study of 341 patients with vertigo","volume":"24","author":"Jongkees","year":"1962","journal-title":"Pract Otorhinolaryngol (Basel)"},{"key":"S0022215112002368_ref11","volume-title":"An Introduction to Medical Statistics","author":"Bland","year":"2009"}],"container-title":["The Journal of Laryngology &amp; Otology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cambridge.org\/core\/services\/aop-cambridge-core\/content\/view\/S0022215112002368","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,4,24]],"date-time":"2019-04-24T21:25:35Z","timestamp":1556141135000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cambridge.org\/core\/product\/identifier\/S0022215112002368\/type\/journal_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,10,26]]},"references-count":13,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2012,12]]}},"alternative-id":["S0022215112002368"],"URL":"https:\/\/doi.org\/10.1017\/s0022215112002368","relation":{},"ISSN":["0022-2151","1748-5460"],"issn-type":[{"value":"0022-2151","type":"print"},{"value":"1748-5460","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,10,26]]}}}