{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,20]],"date-time":"2026-01-20T08:14:41Z","timestamp":1768896881277,"version":"3.49.0"},"reference-count":19,"publisher":"Cambridge University Press (CUP)","issue":"6","license":[{"start":{"date-parts":[[2017,3,14]],"date-time":"2017-03-14T00:00:00Z","timestamp":1489449600000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/www.cambridge.org\/core\/terms"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J. Laryngol. Otol."],"published-print":{"date-parts":[[2017,6]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec id=\"S002221511700055X_sec_a1\"><jats:title>Objective:<\/jats:title><jats:p>This study aimed to evaluate migration of the receiver\u2013stimulator after cochlear implantation using the subperiosteal pocket technique.<\/jats:p><\/jats:sec><jats:sec id=\"S002221511700055X_sec_a2\"><jats:title>Methods:<\/jats:title><jats:p>A prospective clinical study was performed of 32 paediatric patients (aged between 12 months and 8 years; mean \u00b1 standard deviation, 28 \u00b1 19 months) who underwent cochlear implantation in tertiary referral centres. The degree of migration was evaluated using measurements between the receiver\u2013stimulator and selected reference points: the lateral canthus, tragus and mastoid tip. All distances were measured during and six months after surgery.<\/jats:p><\/jats:sec><jats:sec id=\"S002221511700055X_sec_a3\"><jats:title>Results:<\/jats:title><jats:p>No receiver\u2013stimulator migration was observed when using the subperiosteal pocket technique.<\/jats:p><\/jats:sec><jats:sec id=\"S002221511700055X_sec_a4\"><jats:title>Conclusion:<\/jats:title><jats:p>Concerns about implant migration in the subperiosteal pocket technique are unwarranted: this is a safe technique to use for cochlear implantation.<\/jats:p><\/jats:sec>","DOI":"10.1017\/s002221511700055x","type":"journal-article","created":{"date-parts":[[2017,3,14]],"date-time":"2017-03-14T12:46:10Z","timestamp":1489495570000},"page":"487-491","source":"Crossref","is-referenced-by-count":8,"title":["Evaluation of receiver\u2013stimulator migration in cochlear implantation using the subperiosteal pocket technique: a prospective clinical study"],"prefix":"10.1017","volume":"131","author":[{"given":"Y","family":"G\u00fcldiken","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"B","family":"Polat","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"N","family":"Enver","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"L","family":"Aydemir","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"\u015e","family":"\u00c7omo\u011flu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"K S","family":"Orhan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"56","published-online":{"date-parts":[[2017,3,14]]},"reference":[{"key":"S002221511700055X_ref9","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0b013e31827d0943"},{"key":"S002221511700055X_ref14","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijporl.2014.07.002"},{"key":"S002221511700055X_ref4","first-page":"726","article-title":"Osteomyelitis, lateral sinus thrombosis, and temporal lobe infarction caused by infection of a percutaneous cochlear implant","volume":"20","author":"Staecker","year":"1999","journal-title":"Am J Otol"},{"key":"S002221511700055X_ref3","doi-asserted-by":"publisher","DOI":"10.1080\/00016480410022895"},{"key":"S002221511700055X_ref2","doi-asserted-by":"publisher","DOI":"10.1179\/cim.2009.10.2.112"},{"key":"S002221511700055X_ref8","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0b013e318271bb2f"},{"key":"S002221511700055X_ref1","doi-asserted-by":"publisher","DOI":"10.1097\/00129492-200503000-00012"},{"key":"S002221511700055X_ref10","doi-asserted-by":"publisher","DOI":"10.1002\/lary.24649"},{"key":"S002221511700055X_ref18","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0b013e3181fcf04d"},{"key":"S002221511700055X_ref12","doi-asserted-by":"publisher","DOI":"10.1002\/lary.24426"},{"key":"S002221511700055X_ref15","doi-asserted-by":"publisher","DOI":"10.1177\/0194599814567111"},{"key":"S002221511700055X_ref17","first-page":"424","article-title":"Multisection CT as a valuable tool in the postoperative assessment of cochlear implant patients","volume":"26","author":"Verbist","year":"2005","journal-title":"AJNR Am J Neuroradiol"},{"key":"S002221511700055X_ref16","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A1108"},{"key":"S002221511700055X_ref13","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijporl.2013.04.029"},{"key":"S002221511700055X_ref7","doi-asserted-by":"publisher","DOI":"10.1179\/cim.2009.10.3.150"},{"key":"S002221511700055X_ref11","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0b013e3182255949"},{"key":"S002221511700055X_ref19","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0b013e318298aac5"},{"key":"S002221511700055X_ref5","doi-asserted-by":"publisher","DOI":"10.1002\/lary.20204"},{"key":"S002221511700055X_ref6","doi-asserted-by":"publisher","DOI":"10.1002\/lary.21033"}],"container-title":["The Journal of Laryngology &amp; Otology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cambridge.org\/core\/services\/aop-cambridge-core\/content\/view\/S002221511700055X","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,4,17]],"date-time":"2019-04-17T22:00:04Z","timestamp":1555538404000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cambridge.org\/core\/product\/identifier\/S002221511700055X\/type\/journal_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,3,14]]},"references-count":19,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2017,6]]}},"alternative-id":["S002221511700055X"],"URL":"https:\/\/doi.org\/10.1017\/s002221511700055x","relation":{},"ISSN":["0022-2151","1748-5460"],"issn-type":[{"value":"0022-2151","type":"print"},{"value":"1748-5460","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,3,14]]}}}