{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,25]],"date-time":"2026-03-25T06:37:28Z","timestamp":1774420648904,"version":"3.50.1"},"reference-count":22,"publisher":"Cambridge University Press (CUP)","issue":"4","license":[{"start":{"date-parts":[[2023,5,24]],"date-time":"2023-05-24T00:00:00Z","timestamp":1684886400000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/www.cambridge.org\/core\/terms"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J. Laryngol. Otol."],"published-print":{"date-parts":[[2024,4]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec id=\"S0022215123000920_sec_a1\"><jats:title>Objective<\/jats:title><jats:p>This study was designed to determine whether extended high-frequency audiometry was capable of better differentiating between participants with normal hearing who did or did not have subjective tinnitus.<\/jats:p><\/jats:sec><jats:sec id=\"S0022215123000920_sec_a2\" sec-type=\"methods\"><jats:title>Methods<\/jats:title><jats:p>A total of 96 study participants were enrolled: 36 patients with unilateral tinnitus, 28 patients with bilateral tinnitus and 32 volunteers as controls. All 96 participants exhibited normal audiometry findings and hearing thresholds. Extended high-frequency audiometry was used to evaluate these patients.<\/jats:p><\/jats:sec><jats:sec id=\"S0022215123000920_sec_a3\" sec-type=\"results\"><jats:title>Results<\/jats:title><jats:p>There were differences between the extended high-frequency hearing thresholds of affected and unaffected ears in those with unilateral tinnitus, and in the 20\u201329-year-old bilateral tinnitus group, at 11.2, 12.5 and 14 kHz. Unilateral tinnitus subgroups had higher extended high-frequency hearing thresholds than those in control subjects, at all extended high frequencies.<\/jats:p><\/jats:sec><jats:sec id=\"S0022215123000920_sec_a4\" sec-type=\"conclusions\"><jats:title>Conclusion<\/jats:title><jats:p>Extended high-frequency audiometry can offer additional information regarding the hearing status of patients with tinnitus who exhibit normal pure tone thresholds when analysed via conventional hearing thresholds.<\/jats:p><\/jats:sec>","DOI":"10.1017\/s0022215123000920","type":"journal-article","created":{"date-parts":[[2023,5,24]],"date-time":"2023-05-24T07:06:20Z","timestamp":1684911980000},"page":"381-387","source":"Crossref","is-referenced-by-count":3,"title":["The significance of extended high-frequency audiometry in tinnitus patients with normal hearing as evaluated via conventional pure tone audiometry"],"prefix":"10.1017","volume":"138","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0344-7652","authenticated-orcid":false,"given":"Xiaoyan","family":"Ma","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Weidong","family":"Shen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shiming","family":"Yang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fangyuan","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"56","published-online":{"date-parts":[[2023,5,24]]},"reference":[{"key":"S0022215123000920_ref4","first-page":"124","article-title":"Attempts to relieve tinnitus","volume":"2","author":"Vernon","year":"1977","journal-title":"J Am Audiol Soc"},{"key":"S0022215123000920_ref8","doi-asserted-by":"publisher","DOI":"10.4103\/1463-1741.90295"},{"key":"S0022215123000920_ref9","doi-asserted-by":"publisher","DOI":"10.4103\/ejo.ejo_44_18"},{"key":"S0022215123000920_ref17","doi-asserted-by":"publisher","DOI":"10.1016\/S0378-5955(97)00043-9"},{"key":"S0022215123000920_ref11","doi-asserted-by":"publisher","DOI":"10.3109\/00016481003664793"},{"key":"S0022215123000920_ref15","doi-asserted-by":"crossref","first-page":"76","DOI":"10.3766\/jaaa.25.1.6","article-title":"Assessing outcomes of tinnitus intervention","volume":"25","author":"Newman","year":"2014","journal-title":"J Am Acad Audiol"},{"key":"S0022215123000920_ref16","doi-asserted-by":"publisher","DOI":"10.1080\/03655230600895358"},{"key":"S0022215123000920_ref22","doi-asserted-by":"publisher","DOI":"10.3109\/01050399109070792"},{"key":"S0022215123000920_ref14","year":"2005","journal-title":"Guidelines for Manual Pure-Tone Threshold Audiometry"},{"key":"S0022215123000920_ref10","doi-asserted-by":"publisher","DOI":"10.1080\/21695717.2019.1630974"},{"key":"S0022215123000920_ref12","doi-asserted-by":"publisher","DOI":"10.3342\/ceo.2009.2.4.169"},{"key":"S0022215123000920_ref18","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0000000000002983"},{"key":"S0022215123000920_ref5","doi-asserted-by":"publisher","DOI":"10.1016\/j.heares.2019.107826"},{"key":"S0022215123000920_ref20","doi-asserted-by":"publisher","DOI":"10.1016\/j.heares.2020.107922"},{"key":"S0022215123000920_ref13","doi-asserted-by":"publisher","DOI":"10.3109\/00206099009081644"},{"key":"S0022215123000920_ref1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMra013395"},{"key":"S0022215123000920_ref2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(13)60142-7"},{"key":"S0022215123000920_ref19","doi-asserted-by":"publisher","DOI":"10.1016\/j.heares.2006.07.007"},{"key":"S0022215123000920_ref6","doi-asserted-by":"publisher","DOI":"10.1523\/JNEUROSCI.2156-11.2011"},{"key":"S0022215123000920_ref3","doi-asserted-by":"publisher","DOI":"10.3109\/14992027.2010.551220"},{"key":"S0022215123000920_ref7","doi-asserted-by":"publisher","DOI":"10.12659\/MSM.883606"},{"key":"S0022215123000920_ref21","doi-asserted-by":"publisher","DOI":"10.1097\/AUD.0000000000001140"}],"container-title":["The Journal of Laryngology &amp; Otology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cambridge.org\/core\/services\/aop-cambridge-core\/content\/view\/S0022215123000920","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,3,19]],"date-time":"2024-03-19T08:32:26Z","timestamp":1710837146000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cambridge.org\/core\/product\/identifier\/S0022215123000920\/type\/journal_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,5,24]]},"references-count":22,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2024,4]]}},"alternative-id":["S0022215123000920"],"URL":"https:\/\/doi.org\/10.1017\/s0022215123000920","relation":{},"ISSN":["0022-2151","1748-5460"],"issn-type":[{"value":"0022-2151","type":"print"},{"value":"1748-5460","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,5,24]]}}}