{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,23]],"date-time":"2026-07-23T09:48:06Z","timestamp":1784800086472,"version":"3.55.0"},"reference-count":37,"publisher":"Cambridge University Press (CUP)","issue":"8","license":[{"start":{"date-parts":[[2025,4,4]],"date-time":"2025-04-04T00:00:00Z","timestamp":1743724800000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/www.cambridge.org\/core\/terms"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J. Laryngol. Otol."],"published-print":{"date-parts":[[2025,8]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec id=\"S002221512500043X_sec1a\">\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>Bone-conduction hearing devices provide good hearing outcomes for conductive\/mixed hearing losses. Complications post-insertion can lead to additional procedures. Identifying factors that may increase likelihood of developing complications can mitigate risk and inform patients.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"S002221512500043X_sec2b\">\n                    <jats:title>Method<\/jats:title>\n                    <jats:p>A retrospective cohort analysis of 166 adults receiving bone-anchored hearing aid connect operations from 2016\u20132021 was performed assessing complication rate and contributing factors causing revision procedures.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"S002221512500043X_sec3c\">\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Twenty-nine per cent of patients had post-operative complications. In total, 17.5 per cent needed additional procedures. Skin overgrowth\/infection, granulation and traumatic extrusion were most common reasons. No difference was found in complication rate between different surgical techniques, surgeon grade or general versus local anaesthetic. More complications were observed in decreasing age, male gender and severity of skin reaction.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"S002221512500043X_sec4d\">\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Revision procedure and complication rates are similar to those reported in published literature. Patient characteristics are important in identifying those likely to develop complications. Non-patient factors did not seem to affect complication rate.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1017\/s002221512500043x","type":"journal-article","created":{"date-parts":[[2025,4,4]],"date-time":"2025-04-04T03:24:10Z","timestamp":1743737050000},"page":"752-756","source":"Crossref","is-referenced-by-count":1,"title":["Percutaneous bone-anchored hearing rehabilitation in adults: the Nottingham experience over a five-year period"],"prefix":"10.1017","volume":"139","author":[{"ORCID":"https:\/\/orcid.org\/0009-0000-6903-2076","authenticated-orcid":false,"given":"Tony","family":"Hao","sequence":"first","affiliation":[{"name":"Nottingham University Hospitals NHS Trust, Queen\u2019s Medical Centre"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0584-2787","authenticated-orcid":false,"given":"Ali","family":"Ijaz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3044-8503","authenticated-orcid":false,"given":"Wai Sum","family":"Cho","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0961-8865","authenticated-orcid":false,"given":"Anand","family":"Kasbekar","sequence":"additional","affiliation":[{"name":"Nottingham University Hospitals NHS Trust, Queen\u2019s Medical Centre"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"56","published-online":{"date-parts":[[2025,4,4]]},"reference":[{"key":"S002221512500043X_ref13","unstructured":"13 Cochlear Limited. Cochlear BAHA Connect System. Radiographer\u2019s Instructions. MRI for Baha Connect System. In: https:\/\/assets.cochlear.com\/api\/public\/content\/8e34cf5320524d00a67c73951eaf772c [ 4 November 2024 ]"},{"key":"S002221512500043X_ref9","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijporl.2023.111773"},{"key":"S002221512500043X_ref11","unstructured":"11 Cochlear Limited. MRI guidelines for professionals. In: https:\/\/www.cochlear.com\/us\/en\/professionals\/resources-and-training\/mri-guidelines [ 1 November 2024 ]"},{"key":"S002221512500043X_ref30","doi-asserted-by":"publisher","DOI":"10.14639\/0392-100X-N1048"},{"key":"S002221512500043X_ref28","doi-asserted-by":"crossref","first-page":"e505","DOI":"10.1055\/s-0042-1742352","article-title":"Complications of transcutaneous protheses \u2013 a systematic review of publications over the past 10 years","volume":"26","author":"de Souza","year":"2022","journal-title":"Int Arch Otorhinolaryngol"},{"key":"S002221512500043X_ref29","doi-asserted-by":"publisher","DOI":"10.1007\/s00405-022-07778-w"},{"key":"S002221512500043X_ref32","doi-asserted-by":"crossref","first-page":"368","DOI":"10.1055\/s-0037-1613685","article-title":"A comparison of the operative techniques and the postoperative complications for bone-anchored hearing aid implantation","volume":"22","author":"Steehler","year":"2018","journal-title":"Int Arch Otorhinolaryngol"},{"key":"S002221512500043X_ref17","doi-asserted-by":"publisher","DOI":"10.1016\/j.anorl.2012.10.006"},{"key":"S002221512500043X_ref35","doi-asserted-by":"publisher","DOI":"10.1177\/000348941212100809"},{"key":"S002221512500043X_ref19","doi-asserted-by":"publisher","DOI":"10.1097\/00129492-200105000-00010"},{"key":"S002221512500043X_ref10","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0000000000001877"},{"key":"S002221512500043X_ref24","doi-asserted-by":"publisher","DOI":"10.1016\/j.bjorl.2017.03.012"},{"key":"S002221512500043X_ref31","doi-asserted-by":"publisher","DOI":"10.1016\/j.bjorl.2020.07.003"},{"key":"S002221512500043X_ref3","unstructured":"3 Grant, G. Choosing the right bone conduction solution for your patients. Cochlear Pro News. In: https:\/\/pronews.cochlear.com\/which-baha-system-is-right-for-your-patients [ 8 January 2024 ]"},{"key":"S002221512500043X_ref37","unstructured":"37 Office for National Statistics. Adult smoking habits in the UK:2023. In: https:\/\/www.ons.gov.uk\/peoplepopulationandcommunity\/healthandsocialcare\/healthandlifeexpectancies\/bulletins\/adultsmokinghabitsingreatbritain\/2023#:\u223c:text=Smoking%20in%20the%20UK%20and%20constituent%20countries,-The%20Annual%20Population&text=In%202023%2C%2011.9%25%20of%20adults,not%20a%20statistically%20significant%20one [ 1 June 2024 ]"},{"key":"S002221512500043X_ref12","unstructured":"12 Cochlear Limited. MRI Considerations. In: www.cochlear.com\/mri"},{"key":"S002221512500043X_ref33","doi-asserted-by":"publisher","DOI":"10.1177\/0003489419891451"},{"key":"S002221512500043X_ref20","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0b013e31802c74c4"},{"key":"S002221512500043X_ref14","doi-asserted-by":"publisher","DOI":"10.1007\/s00405-023-08099-2"},{"key":"S002221512500043X_ref4","unstructured":"4 NHS Commissioning Board. Clinical Commissioning Policy: Bone Anchored Hearing Aids. April 2013. Reference: NHSCB\/D09\/P\/a [ 8 January 2024 ]"},{"key":"S002221512500043X_ref22","doi-asserted-by":"publisher","DOI":"10.1017\/S0022215108002521"},{"key":"S002221512500043X_ref18","doi-asserted-by":"publisher","DOI":"10.1007\/s00405-010-1293-0"},{"key":"S002221512500043X_ref21","doi-asserted-by":"publisher","DOI":"10.1017\/S0022215106001277"},{"key":"S002221512500043X_ref23","doi-asserted-by":"publisher","DOI":"10.1093\/bjs\/znac269.186"},{"key":"S002221512500043X_ref15","doi-asserted-by":"publisher","DOI":"10.1111\/coa.13556"},{"key":"S002221512500043X_ref6","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjoto.2022.103758"},{"key":"S002221512500043X_ref34","doi-asserted-by":"publisher","DOI":"10.1007\/s00405-016-4106-2"},{"key":"S002221512500043X_ref5","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0b013e318291c651"},{"key":"S002221512500043X_ref1","unstructured":"1 National Institute for Health and Care Excellence (NICE). Hearing Loss in Adults. In: https:\/\/cks.nice.org.uk\/topics\/hearing-loss-in-adults [ 8 January 2024 ]"},{"key":"S002221512500043X_ref26","doi-asserted-by":"publisher","DOI":"10.1007\/s12070-016-1002-4"},{"key":"S002221512500043X_ref27","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0b013e318187e186"},{"key":"S002221512500043X_ref7","doi-asserted-by":"publisher","DOI":"10.1017\/S0022215109991708"},{"key":"S002221512500043X_ref25","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijporl.2011.01.018"},{"key":"S002221512500043X_ref8","doi-asserted-by":"publisher","DOI":"10.1016\/j.otohns.2005.10.027"},{"key":"S002221512500043X_ref16","first-page":"56","article-title":"Soft tissue reactions around percutaneous implants: a clinical study of soft tissue conditions around skin-penetrating titanium implants for bone-anchored hearing aids","volume":"9","author":"Holgers","year":"1988","journal-title":"Am J Otol"},{"key":"S002221512500043X_ref36","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0000000000003046"},{"key":"S002221512500043X_ref2","doi-asserted-by":"publisher","DOI":"10.1177\/014556139407300210"}],"container-title":["The Journal of Laryngology &amp; Otology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cambridge.org\/core\/services\/aop-cambridge-core\/content\/view\/S002221512500043X","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,22]],"date-time":"2026-02-22T03:59:28Z","timestamp":1771732768000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cambridge.org\/core\/product\/identifier\/S002221512500043X\/type\/journal_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4,4]]},"references-count":37,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2025,8]]}},"alternative-id":["S002221512500043X"],"URL":"https:\/\/doi.org\/10.1017\/s002221512500043x","relation":{},"ISSN":["0022-2151","1748-5460"],"issn-type":[{"value":"0022-2151","type":"print"},{"value":"1748-5460","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4,4]]}}}