{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,4]],"date-time":"2026-10-04T13:41:51Z","timestamp":1791121311152,"version":"4.1.0"},"reference-count":27,"publisher":"Cambridge University Press (CUP)","issue":"2","license":[{"start":{"date-parts":[[2009,5,15]],"date-time":"2009-05-15T00:00:00Z","timestamp":1242345600000},"content-version":"unspecified","delay-in-days":5705,"URL":"https:\/\/www.cambridge.org\/core\/terms"}],"content-domain":{"domain":["journals.cambridge.org"],"crossmark-restriction":true},"short-container-title":["Epidemiol. Infect."],"published-print":{"date-parts":[[1993,10]]},"abstract":"<jats:title>Summary<\/jats:title><jats:p>Cooling towers have been demonstrated to be amplifiers and disseminators of legionella, the causative organism of Legionnaires' disease. Community outbreaks associated with cooling towers have been reported with several common factors. Small towers (&lt; 300 kW) have predominantly been implicated in outbreaks. Cooling tower-associated outbreaks are most frequent in autumn, and frequently implicated systems have been operated after a period of shutdown.<\/jats:p><jats:p>This paper reports field study data relating system operation to legionella colonization of systems. Operating systems have been shown to be more frequently colonized by legionella than shutdown systems. In some cases operation of systems after periods of shutdown raised legionella concentrations from below detection limits to between 50 and 950 c.f.u.\/ml within 10 min.<\/jats:p><jats:p>These data and previously reported data relating to biofilm and sediment colonization of the systems, and community outbreaks of Legionnaires' disease, have been used to develop a model explaining the seasonal nature of outbreaks associated with irregularly operated, small cooling tower systems.<\/jats:p>","DOI":"10.1017\/s0950268800056995","type":"journal-article","created":{"date-parts":[[2009,5,15]],"date-time":"2009-05-15T08:57:14Z","timestamp":1242377834000},"page":"287-295","update-policy":"https:\/\/doi.org\/10.1017\/policypage","source":"Crossref","is-referenced-by-count":47,"title":["A model for autumn outbreaks of Legionnaires' disease associated with cooling towers, linked to system operation and size"],"prefix":"10.1017","volume":"111","author":[{"given":"R. H.","family":"Bentham","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"C. R.","family":"Broadbent","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"56","published-online":{"date-parts":[[2009,5,15]]},"reference":[{"key":"S0950268800056995_ref013","unstructured":"13. Levy M , Westley-Wise V , Frommer M , Report on Legionnaires' disease in South Western Sydney, April 1992. South Western Sydney Area Health Service Public Health Unit. New South Wales Health Department 1992."},{"key":"S0950268800056995_ref011","doi-asserted-by":"publisher","DOI":"10.1001\/jama.1985.03360040075028"},{"key":"S0950268800056995_ref004","unstructured":"4. Fliermans CB . State of the art lecture. Philosophical ecology: Legionella in historical perspective. In: Thornsberry C , Balows A , Feeley JC , Jakubowski W , eds. Legionella: proceedings of the second international Legionella symposium. Washington:American Society for Microbiology1984: 285\u20139."},{"key":"S0950268800056995_ref017","doi-asserted-by":"publisher","DOI":"10.1017\/S0950268800030648"},{"key":"S0950268800056995_ref007","doi-asserted-by":"publisher","DOI":"10.1093\/infdis\/159.3.572"},{"key":"S0950268800056995_ref022","first-page":"31","volume-title":"A laboratory manual for Legionella","author":"Dennis","year":"1988"},{"key":"S0950268800056995_ref016","doi-asserted-by":"publisher","DOI":"10.3109\/inf.1983.15.issue-1.08"},{"key":"S0950268800056995_ref027","unstructured":"27. Smith MH , Stewart CJ . Air conditioning condenser cooling systems: Cost considerations. Building Services Research Information Association (UK). Technical Memorandum 1\/90. 1990."},{"key":"S0950268800056995_ref024","doi-asserted-by":"publisher","DOI":"10.7326\/0003-4819-100-3-333"},{"key":"S0950268800056995_ref020","first-page":"20","article-title":"Legionella ecology in cooling towers. Australian Institute of Refrigeration","author":"Broadbent","year":"1992","journal-title":"Air Conditioning and Heating Journal"},{"key":"S0950268800056995_ref018","doi-asserted-by":"publisher","DOI":"10.1017\/S0950268800047385"},{"key":"S0950268800056995_ref006","doi-asserted-by":"publisher","DOI":"10.1016\/0195-6701(88)90186-7"},{"key":"S0950268800056995_ref008","doi-asserted-by":"publisher","DOI":"10.1093\/oxfordjournals.aje.a112517"},{"key":"S0950268800056995_ref019","volume-title":"Legionella and building services","author":"Brundrett","year":"1992"},{"key":"S0950268800056995_ref001","doi-asserted-by":"crossref","first-page":"127","DOI":"10.5694\/j.1326-5377.1987.tb133302.x","article-title":"Epidemic of Legionnaires' disease in Wollongong","volume":"147","author":"Christopher","year":"1987","journal-title":"Med J Aust"},{"key":"S0950268800056995_ref003","doi-asserted-by":"publisher","DOI":"10.1016\/0163-4453(91)91569-J"},{"key":"S0950268800056995_ref005","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM198002143020703"},{"key":"S0950268800056995_ref009","volume-title":"Legionella Infections","author":"Bartlett","year":"1986"},{"key":"S0950268800056995_ref010","doi-asserted-by":"publisher","DOI":"10.1093\/infdis\/161.6.1257"},{"key":"S0950268800056995_ref012","unstructured":"12. Johnson AG . Report on disinfecting and cleaning of cooling towers at Repatriation General Hospital \u2013 Daw Park. Australian Department of Housing and Construction 1986."},{"key":"S0950268800056995_ref014","doi-asserted-by":"publisher","DOI":"10.1017\/S095026880005932X"},{"key":"S0950268800056995_ref015","first-page":"630","article-title":"Outbreak of Legionnaires' disease from a cooling water system in a power station","volume":"43","author":"Morton","year":"1986","journal-title":"Br J Indust Med"},{"key":"S0950268800056995_ref021","first-page":"267","volume-title":"Legionella: current status and emerging perspectives","author":"Bentham","year":"1993"},{"key":"S0950268800056995_ref023","doi-asserted-by":"publisher","DOI":"10.1146\/annurev.mi.41.100187.002251"},{"key":"S0950268800056995_ref025","first-page":"22","article-title":"Practical measures to control Legionnaires' disease hazards. Australian Institute of Refrigeration","author":"Broadbent","year":"1987","journal-title":"Air Conditioning and Heating Journal"},{"key":"S0950268800056995_ref026","unstructured":"26. Technical Information 178 ME, Measures to control Legionnaires' disease hazards in buildings. Australian Department of Administrative Services. 1987."},{"key":"S0950268800056995_ref002","unstructured":"2. Christley S , Rubin G , Christopher P . Legionnaires' disease Sydney. NSW. Department of Health, New South Wales Epidemiology and Health Services Evaluation Branch Report. April 1989."}],"container-title":["Epidemiology and Infection"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cambridge.org\/core\/services\/aop-cambridge-core\/content\/view\/S0950268800056995","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,5,18]],"date-time":"2020-05-18T05:04:48Z","timestamp":1589778288000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cambridge.org\/core\/product\/identifier\/S0950268800056995\/type\/journal_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1993,10]]},"references-count":27,"journal-issue":{"issue":"2","published-print":{"date-parts":[[1993,10]]}},"alternative-id":["S0950268800056995"],"URL":"https:\/\/doi.org\/10.1017\/s0950268800056995","relation":{},"ISSN":["0950-2688","1469-4409"],"issn-type":[{"value":"0950-2688","type":"print"},{"value":"1469-4409","type":"electronic"}],"subject":[],"published":{"date-parts":[[1993,10]]},"assertion":[{"value":"Copyright \u00a9 Cambridge University Press 1993","name":"license","label":"License","group":{"name":"copyright_and_licensing","label":"Copyright and Licensing"}}]}}