{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,27]],"date-time":"2025-10-27T10:36:51Z","timestamp":1761561411439},"reference-count":14,"publisher":"Cambridge University Press (CUP)","issue":"2","license":[{"start":{"date-parts":[[2010,3,11]],"date-time":"2010-03-11T00:00:00Z","timestamp":1268265600000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/www.cambridge.org\/core\/terms"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Cardiol Young"],"published-print":{"date-parts":[[2010,4]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec id=\"S1047951109990631_abs1\" sec-type=\"general\"><jats:title>Background<\/jats:title><jats:p>Usually the literature results for device-closure of patent oval foramen concern a single type of device or different devices implanted without anatomical preferences. We propose a strategy of device type and selection based on intra-cardiac echocardiography measurements of inter-atrial septum characteristics.<\/jats:p><\/jats:sec><jats:sec id=\"S1047951109990631_abs2\" sec-type=\"methods\"><jats:title>Methods<\/jats:title><jats:p>We prospectively enrolled 100 consecutive patients with amean age of 43 plus or minus 15.5 years, 68 females, who had been referred to our centre for catheter-based closure of inter-atrial shunts over a 48-month period. On the basis of intra-cardiac echocardiography findings the operators selected the Amplatzer Occluder family (AGA Medical Corporation) or the Premere Closure System (St Jude Medical Inc.). Determinants of the selection process were presence and extension of atrial septal aneurysm, tunnel length, rims length, and thickness, presence of additional fenestrations.<\/jats:p><\/jats:sec><jats:sec id=\"S1047951109990631_abs3\" sec-type=\"results\"><jats:title>Results<\/jats:title><jats:p>According on intra-cardiac echocardiography study, 26 patients have a long channel patent oval foramen, 44 patients had a large atrial septal aneurysm (more than four RL), 24 patients had a moderate atrial septal aneurysm (more than two RL but less than four right-to-left), and six patients had hypertrophic rims. Thus, the Amplatzer PFO Occluder was selected in 24 patients, the Amplatzer ASD Cribriform Occluder in 44 patients, and the Premere device in 32 cases. No aortic erosions, device thrombosis, or recurrent ischaemic cerebral events were observed. Pre-discharge and follow-up occlusion rates were 91% and 96%, respectively.<\/jats:p><\/jats:sec><jats:sec id=\"S1047951109990631_abs4\" sec-type=\"conclusion\"><jats:title>Conclusions<\/jats:title><jats:p>Our study suggested that such strategy driven from identification and measurements of the right atrium and inter-atrial septum components resulted in low complications and high-success rates, mandatory conditions when facing with otherwise healthy subjects, such as the patients with patent oval foramen.<\/jats:p><\/jats:sec>","DOI":"10.1017\/s1047951109990631","type":"journal-article","created":{"date-parts":[[2010,3,11]],"date-time":"2010-03-11T10:18:16Z","timestamp":1268302696000},"page":"144-149","source":"Crossref","is-referenced-by-count":20,"title":["Patent oval foramen transcatheter closure: results of a strategy based on tailoring the device to the specific patient\u2019s anatomy"],"prefix":"10.1017","volume":"20","author":[{"given":"Gianluca","family":"Rigatelli","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fabio","family":"Dell\u2019Avvocata","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Federico","family":"Ronco","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Massimo","family":"Giordan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Paolo","family":"Cardaioli","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"56","published-online":{"date-parts":[[2010,3,11]]},"reference":[{"key":"S1047951109990631_ref4","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8183.2008.00364.x"},{"key":"S1047951109990631_ref12","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2003.10.030"},{"key":"S1047951109990631_ref9","first-page":"262","article-title":"Catheter closure of perforated secundum atrial septal defect under intracardiac echocardiographic guidance using a single amplatzer device: feasibility of a new method","volume":"17","author":"Zanchetta","year":"2005","journal-title":"J Invasive Cardiol"},{"key":"S1047951109990631_ref14","doi-asserted-by":"publisher","DOI":"10.1016\/j.echo.2004.06.033"},{"key":"S1047951109990631_ref11","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8183.2005.00094.x"},{"key":"S1047951109990631_ref6","doi-asserted-by":"publisher","DOI":"10.1016\/j.euje.2005.12.014"},{"key":"S1047951109990631_ref10","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.88.2.621"},{"key":"S1047951109990631_ref1","article-title":"Long-term outcome of transcatheter patent foramen ovale closure in patients with paradoxical embolism","author":"Cifarelli","year":"2009","journal-title":"Int J Cardiol"},{"key":"S1047951109990631_ref13","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.20211"},{"key":"S1047951109990631_ref5","doi-asserted-by":"publisher","DOI":"10.1212\/WNL.62.9.1468"},{"key":"S1047951109990631_ref3","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijcard.2008.02.031"},{"key":"S1047951109990631_ref2","first-page":"442","article-title":"Comparison of contemporary devices used for transcatheter patent foramen ovale closure","volume":"20","author":"Spies","year":"2008","journal-title":"J Invasive Cardiol"},{"key":"S1047951109990631_ref8","doi-asserted-by":"publisher","DOI":"10.1016\/S0894-7317(97)70027-0"},{"key":"S1047951109990631_ref7","first-page":"225","article-title":"Intracardiac echocardiography in cardiovascular catheter-based interventions: different devices for different purposes","volume":"18","author":"Rigatelli","year":"2006","journal-title":"J Invasive Cardiol"}],"container-title":["Cardiology in the Young"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cambridge.org\/core\/services\/aop-cambridge-core\/content\/view\/S1047951109990631","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,4,28]],"date-time":"2019-04-28T20:18:18Z","timestamp":1556482698000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cambridge.org\/core\/product\/identifier\/S1047951109990631\/type\/journal_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,3,11]]},"references-count":14,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2010,4]]}},"alternative-id":["S1047951109990631"],"URL":"https:\/\/doi.org\/10.1017\/s1047951109990631","relation":{},"ISSN":["1047-9511","1467-1107"],"issn-type":[{"value":"1047-9511","type":"print"},{"value":"1467-1107","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,3,11]]}}}