{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,21]],"date-time":"2025-10-21T03:24:31Z","timestamp":1761017071038},"reference-count":11,"publisher":"Cambridge University Press (CUP)","issue":"5","license":[{"start":{"date-parts":[[2014,7,15]],"date-time":"2014-07-15T00:00:00Z","timestamp":1405382400000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/www.cambridge.org\/core\/terms"}],"content-domain":{"domain":["journals.cambridge.org"],"crossmark-restriction":true},"short-container-title":["Cardiol Young"],"published-print":{"date-parts":[[2015,6]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p><jats:italic>Background:<\/jats:italic> To study the feasibility and complications associated with the use of ductal occluders for closure of perimembranous ventricular septal defects. <jats:italic>Methods:<\/jats:italic> A total of 126 patients, ranging from 1 to 41 years of age (median \u2013 8 years), underwent closure of ventricular septal defects from August 2010 to April 2013. Small- and moderate-sized defects were closed using first-generation Patent ductus arteriosus occluders or Amplatzer Duct Occluder-II. Patients were followed up for the development of complications such as heart block, aortic regurgitation, and tricuspid regurgitation. <jats:italic>Results:<\/jats:italic> Patent ductus arteriosus occluders were used in 81 patients, and the Amplatzer Duct Occluder-II device in 45 patients. The devices were successfully deployed in 99.2% of the cases. One patient had embolisation of an Amplatzer Duct Occluder-II device soon after deployment. There was one case of transient complete heart block (0.8%) needing temporary pacing, and two cases of isoarrhythmic atrioventricular dissociation (1.6%). One patient developed late-onset complete heart block 15 months after the procedure and underwent permanent pacemaker implantation. There were no instances of new-onset aortic regurgitation. New-onset mild tricuspid regurgitation was seen in two patients. Of the patients, three had small residual shunts on follow-up, without haemolysis. <jats:italic>Conclusions:<\/jats:italic> Duct occluders can be used to effectively close small- and moderate-sized ventricular septal defects. The incidence of complete heart block and valvular regurgitations are much less than reported with other devices, and they are cost-effective.<\/jats:p>","DOI":"10.1017\/s1047951114001255","type":"journal-article","created":{"date-parts":[[2014,7,15]],"date-time":"2014-07-15T08:43:54Z","timestamp":1405413834000},"page":"918-926","update-policy":"http:\/\/dx.doi.org\/10.1017\/policypage","source":"Crossref","is-referenced-by-count":13,"title":["Transcatheter closure of perimembranous ventricular septal defects with ductal occluders"],"prefix":"10.1017","volume":"25","author":[{"given":"Jayaranganath","family":"Mahimarangaiah","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anand","family":"Subramanian","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Srinivasa","family":"Kikkeri Hemannasetty","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Subhash","family":"Chandra","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Satish","family":"Karur","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Usha","family":"Mandikal Kodandaramasastry","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Manjunath","family":"Cholenahally Nanjappa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"56","published-online":{"date-parts":[[2014,7,15]]},"reference":[{"key":"S1047951114001255_ref6","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2005.09.028"},{"key":"S1047951114001255_ref5","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2007.03.068"},{"key":"S1047951114001255_ref9","first-page":"1","article-title":"Does the technique of interventional closure of perimembranous ventricular septal defect reduce the incidence of heart block?","volume":"1","author":"Bentham","year":"2011","journal-title":"Cardiol Young"},{"key":"S1047951114001255_ref3","first-page":"667","volume-title":"Moss and Adams\u2019 Heart Disease in Infants, Children and Adolescents Including the Fetus and Young Adult","author":"McDaniel","year":"2008"},{"key":"S1047951114001255_ref8","unstructured":"Hieu NL . Transcatheter Closure of Ventricular Septal Defect with New Devices in Vietnam. Proceedings from China Interventional Therapeutics summit, 2010."},{"key":"S1047951114001255_ref1","doi-asserted-by":"publisher","DOI":"10.1136\/hrt.43.3.332"},{"key":"S1047951114001255_ref11","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2012.08.1004"},{"key":"S1047951114001255_ref4","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjcard.2008.02.069"},{"key":"S1047951114001255_ref10","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.22675"},{"key":"S1047951114001255_ref2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.14.3.349"},{"key":"S1047951114001255_ref7","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.23074"}],"container-title":["Cardiology in the Young"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cambridge.org\/core\/services\/aop-cambridge-core\/content\/view\/S1047951114001255","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,4,21]],"date-time":"2019-04-21T00:36:03Z","timestamp":1555806963000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cambridge.org\/core\/product\/identifier\/S1047951114001255\/type\/journal_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,7,15]]},"references-count":11,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2015,6]]}},"alternative-id":["S1047951114001255"],"URL":"https:\/\/doi.org\/10.1017\/s1047951114001255","relation":{},"ISSN":["1047-9511","1467-1107"],"issn-type":[{"value":"1047-9511","type":"print"},{"value":"1467-1107","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,7,15]]},"assertion":[{"value":"\u00a9 Cambridge University Press 2014\u00a0","name":"license","label":"License","group":{"name":"copyright_and_licensing","label":"Copyright and Licensing"}}]}}