{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,29]],"date-time":"2025-10-29T19:37:56Z","timestamp":1761766676203,"version":"3.40.5"},"reference-count":17,"publisher":"Cambridge University Press (CUP)","issue":"2","license":[{"start":{"date-parts":[[2020,1,30]],"date-time":"2020-01-30T00:00:00Z","timestamp":1580342400000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/www.cambridge.org\/core\/terms"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Cardiol Young"],"published-print":{"date-parts":[[2020,2]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec id=\"S1047951120000104_as1\" sec-type=\"other\"><jats:title>Objective:<\/jats:title><jats:p>To evaluate the feasibility, efficacy, and safety of Amplatzer vascular plug II in large and elongated ducts in infants.<\/jats:p><\/jats:sec><jats:sec id=\"S1047951120000104_as2\" sec-type=\"other\"><jats:title>Introduction:<\/jats:title><jats:p>Patent arterial duct device closure is technically challenging in infants with large and elongated ducts because Amplatzer duct occluder and Amplatzer duct occluder II have high chances of causing aortic coarctation and left pulmonary artery stenosis, respectively. The Amplatzer vascular plug II being soft with no retention discs on either sides helps in mitigating these problems.<\/jats:p><\/jats:sec><jats:sec id=\"S1047951120000104_as3\" sec-type=\"other\"><jats:title>Method:<\/jats:title><jats:p>This is a prospective, observational study involving infants with clinical, echocardiographic and angiographic evidence of large left to right shunt. All the children underwent duct closure using Amplatzer vascular plug II.<\/jats:p><\/jats:sec><jats:sec id=\"S1047951120000104_as4\" sec-type=\"other\"><jats:title>Results:<\/jats:title><jats:p>Eighteen infants qualified for the study. Mean age and weight were 8.63 \u00b1 3.84 months and 6.3 \u00b1 1.7 kg, respectively. The angiographic mean duct diameter at the pulmonary artery end was 4.66 \u00b1 0.92 mm, and the mean duct length was 9.4 \u00b1 2.48 mm. The size of Amplatzer vascular plug II used varied from 6 mm to 10 mm. Technical success was achieved in 16\/18 cases. One patient had device embolisation, and in the other, the device was found to be unstable. The ratio of Amplatzer vascular plug II size to the duct diameter was 1.65 \u00b1 0.27, while the ratio of ductal length to device length was 1.48 \u00b1 0.46 in those with successful outcome.<\/jats:p><\/jats:sec><jats:sec id=\"S1047951120000104_as5\" sec-type=\"other\"><jats:title>Conclusions:<\/jats:title><jats:p>Amplatzer vascular plug II is a safe and effective option in appropriately selected infants with elongated ducts. Diameter and length of Amplatzer vascular plug II vis-a-vis those of the ductus are important determinants of the successful outcome.<\/jats:p><\/jats:sec>","DOI":"10.1017\/s1047951120000104","type":"journal-article","created":{"date-parts":[[2020,1,30]],"date-time":"2020-01-30T06:43:25Z","timestamp":1580366605000},"page":"243-248","source":"Crossref","is-referenced-by-count":7,"title":["Transcatheter closure of elongated and pulmonary hypertensive patent arterial duct in infants using Amplatzer vascular plug II"],"prefix":"10.1017","volume":"30","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9614-2959","authenticated-orcid":false,"given":"Sneha M.","family":"Jain","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Priya M.","family":"Pradhan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Supratim","family":"Sen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bharat V.","family":"Dalvi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"56","published-online":{"date-parts":[[2020,1,30]]},"reference":[{"key":"S1047951120000104_ref16","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(89)90064-7"},{"key":"S1047951120000104_ref15","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.27824"},{"key":"S1047951120000104_ref14","doi-asserted-by":"publisher","DOI":"10.1111\/joic.12188"},{"key":"S1047951120000104_ref12","first-page":"191","article-title":"Percutaneous occlusion of patent ductus arteriosus with the Amplatzer\u00ae vascular plug II device: early experience in three reference centers","volume":"20","author":"Sant\u2019Anna","year":"2012","journal-title":"Rev Bras de Cardiol Invasiva"},{"key":"S1047951120000104_ref11","doi-asserted-by":"publisher","DOI":"10.1016\/j.ahj.2008.08.001"},{"key":"S1047951120000104_ref10","doi-asserted-by":"publisher","DOI":"10.5830\/CVJA-2013-033"},{"key":"S1047951120000104_ref8","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2004.03.074"},{"key":"S1047951120000104_ref4","doi-asserted-by":"publisher","DOI":"10.3346\/jkms.2007.22.3.484"},{"key":"S1047951120000104_ref3","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.22370"},{"key":"S1047951120000104_ref1","doi-asserted-by":"publisher","DOI":"10.1542\/peds.2016-2927"},{"key":"S1047951120000104_ref5","doi-asserted-by":"publisher","DOI":"10.1007\/s00246-012-0393-6"},{"key":"S1047951120000104_ref17","doi-asserted-by":"crossref","first-page":"132","DOI":"10.4103\/0974-2069.115255","article-title":"Amplatzer vascular plugs in congenital cardiovascular malformations","volume":"6","author":"Barwad","year":"2013","journal-title":"Ann Pediatr Cardiol"},{"key":"S1047951120000104_ref13","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.24707"},{"key":"S1047951120000104_ref2","doi-asserted-by":"crossref","first-page":"e000424","DOI":"10.1161\/JAHA.113.000424","article-title":"Safety of percutaneous patent ductus arteriosus closure: an unselected multicenter population experience","volume":"2","author":"El-Said","year":"2013","journal-title":"J Am Heart Assoc Cardiovasc Cerebrovasc Dis"},{"key":"S1047951120000104_ref7","doi-asserted-by":"publisher","DOI":"10.1136\/hrt.82.1.109"},{"key":"S1047951120000104_ref6","doi-asserted-by":"publisher","DOI":"10.1016\/j.ahj.2005.12.010"},{"key":"S1047951120000104_ref9","doi-asserted-by":"publisher","DOI":"10.1017\/S104795111900091X"}],"container-title":["Cardiology in the Young"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cambridge.org\/core\/services\/aop-cambridge-core\/content\/view\/S1047951120000104","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,10,13]],"date-time":"2022-10-13T12:46:31Z","timestamp":1665665191000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cambridge.org\/core\/product\/identifier\/S1047951120000104\/type\/journal_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,1,30]]},"references-count":17,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2020,2]]}},"alternative-id":["S1047951120000104"],"URL":"https:\/\/doi.org\/10.1017\/s1047951120000104","relation":{},"ISSN":["1047-9511","1467-1107"],"issn-type":[{"type":"print","value":"1047-9511"},{"type":"electronic","value":"1467-1107"}],"subject":[],"published":{"date-parts":[[2020,1,30]]}}}